Web Analytics Made Easy - StatCounter

Certificate Tenders

Get complete information related to latest Certificate Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Certificate Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Certificate Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45470964 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For supply of digital dial snap gauge with least count 0.001 mm, range: 300-325 mm. detail specification as per annexure attached. note: the firm shall submit nabl calibration certificate along with the supply.[ warranty period: 18 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45473641 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For (for vande bharat) cordless brushless impact wrench 1/2 inch drive as per technical specification attached in annexure-a. make-bahco/enerpack/stahvely/norbar/snap-on or equivalent. supply acceptable from authorized dealer and oem certificate required. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45472792 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For supply of brass link for small terminal block, thickness 1 mm plus/minus +/- 0.1 mm (instead of 0.5 mm) as per drg. no. s&t/by/f- 388. the test certificate from nabl accredited lab to be submitted alongwithmaterial.(shop no.07) [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45473041 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For supply of spares as per attached annexure a suitable for kaeser make air compressor, plant no. 2191, 2192, 2193 and 2194 model no. bsd -72 with fitment certificate - oil filter 25 bar, air filter cartridge - new design (ring shape), air oil separator cartridge kit, 220 x 270 mm dia, repair kit - mpcv, revision inlet valve kit, cavv repair kit, combination valve repair kit

Central Government/Public Sector

CTN :45472871 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For supply of octagonal boom section-04 as per drg no: rdso/s-11600 duly painted. party should submit nabl authorised lab certificate along with material.(shop no.10) [ warranty period: 30 months after thedate of delivery ] ]

Central Government/Public Sector

CTN :45471206 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For supply of m.s square bar piece , size 10 x10 x 25 mm long. note: nabl test certificate must be supplywith material. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45473744 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply of tooth spacing k value checking go & no go gauge for bull gear 107 teeth for wag-9 / wag-9 hc loco. size: go: 317.09/317.17 mm & no go: 316.49 mm, ref. rdso drawing no. sk.dp-3848, material: tool steel - is- 3748/90, hardness:40/45 hrc and supply with calibration certificate. [ warranty period: 30 months after the date of delivery ] ]

Central Government / Public Sector

CTN :45471172 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For supply of set of chemicals, consist of 03 items such as (a). buffer solution, ph - 4.0 (phthalate), (b). ph - 7.0 (phosphate), (c). ph -9.2, qty- 500 ml each along with calibration certificate form nabl accriditied laboratory with nabl traceability. ]

Central Government And Public Sector

CTN :45471313 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For supply of break stem rivet for fitment of rfid tags on locomotives as per annexure- a. material: steel with zinc coating as per attached oem certificate. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

State Government

CTN :45263804 Due date: 22 Jun, 202622 Jun, 2026 4.63 Crore
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r
 Loading, Please wait...

Connect us via What's Up