Tender For tender for the work of construction of compound wall by raising the existing compound wall around 220 kv power receiving substation (from somanahalli /nrs lilo line) and providing approach road surrounding cwss stage-4 phase-ii pump house at tataguni and 66 kv switch yard at tataguni
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For supply of highly skilled supervisor , skilled , semi skilled , un skilled , highly skilled data entry operator , 1.50 sqmm single core of 90 mtr coil , 2.50 sqmm single core of 90 mtr coil , 3 core x 1.5 sqmm of 100 mtr coil , 3 core x 2.5 sqmm of 100 mtr coil , modular plate of two module , modular plate of three module , modular plate of six module , modular plate of eight module , inner plate of two module , inner plate of three module , inner plate of six module , inner plate of eight module , two module flush metal gi boxes , three module flush metal gi boxes , 16 a one way modular switch , 10 a one way modular switch , 06 a 3 pin shuttered socket , 16 a 3 pin shuttered socket , 10 a one way bell push switch , 06 amp 3 pin plug tops , 16 amp 3 pin plug tops , 16 a one way piano type switch , 06 a one way piano type switch , 20 a two in one piano type socket , 06 a two in one piano type socket , 2.5 mfd rating capacitor , 4 mfd rating capacitor , 20 amp switch socket combined with box , 06 amp switch socket combined with box , extension cord with 04 universal socket , 10 sq mm aluminium tube terminal , 16 sq mm aluminium tube terminal , 25 sq mm aluminium tube terminal , 35 sq mm aluminium tube terminal , 50 sq mm aluminium tube terminal , 70 sq mm aluminium tube terminal , 95 sq mm aluminium tube terminal , 120 sq mm aluminium tube terminal , 150 sq mm aluminium tube terminal , 185 sq mm aluminium tube terminal , 240 sq mm aluminium tube terminal , 16 sq mm aluminium in line connector ferrule , 25 sq mm aluminium in line connector ferrule , 35 sq mm aluminium in line connector ferrule , 50 sq mm aluminium in line connector ferrule , 70 sq mm aluminium in line connector ferrule , 95 sq mm aluminium in line connector ferrule , 120 sq mm aluminium in line connector ferrule , 150 sq mm aluminium in line connector ferrule , 185 sq mm aluminium in line connector ferrule , 240 sq mm aluminium in line connector ferrule , plastic insulation self adhesive tape of 1.8 cm width and 7.5 mtr. length , 9w led lamp , 32 x 16 mm pvc white trunking , wireless call door bell including bell switch , door bell suitable to operate on 230v 50 hz ac supply , 100 watt incandescent filament bulb , 2 way gang box , 3 way gang box , 4 way gang box , supply of 4 x 16 sqmm lt cable , supply of 3.5 x 240 sqmm lt cable , supply of led aviation obstruction light , supply of 80 watt round shape led bay light suitable to operate on 230 volt 50 hz supply , supply of 250 watt led floodlight suitable to operate on 230 volt 50 hz ac , supply of insulating transformer mineral oil , 12 volt, 200ah lead acid battery , 12 volt, 180ah lead acid battery , 12 volt,150ah lead acid battery , 12 volt, 42ah smf-vrla battery , supply of acb edo type 3200 a fp fault breaking capacity 65 ka , installation testing and commissioning of new acb edo type 3200 a four pole , visiting charges for synchronizing panel by stucke or allen bradley or siemen as per site , visiting charge for any modification required in plc programming by deputing stucke or allen bradley or siemens as per site , execution of the item of work as per requirement of site from the cpwd schedule of rate
Tender For repairing and maintenance of 440v and 220v overhead distribution line of various bccl colonies i.e. premnagar, kalinagr, hanumannagar, bilbera 36 unit, officer colony, filter plant etc, under bilbera switch station of govindpur area
Tender For tender for supply of hexagon head screw , shaft seal cover , gasket , benzing ring , unloading cylinder with single pipe connection , unloading cylinder for single pipe connection 94point4mm , unloading cylinder for single pipe connection 112point4 , rocker for unloading mechanism , bearing cup , spring , cup washer , split pin , piston ring , oil scrapper ring , spring for safety head , gasket , coils for contactor , toggle switch , door limit switch , power contactor 12a , winding protection relay , timer , ammeter selector switch , red led lamp , fuse 2a , fuse 32a , fuse 6a , thermostat for cool room , thermostat for cold room , propeller fan for cold room cooler , oil separator , terminal stud assembly for motor , discharge valve retpoint ring plate , gear shaft for oil pump , neoprene o ring , crank case heater element , dispoint pressure gauges for r 22 , oil pressure switch , low pressure switch , high pressure switch , gasket set for condensers , zinc plug , safety valve for condenser , gasket set for condenser , pressure gauges water , temppointgauges room temp , over load relay , ring end spanner set , pulley puller 12 , screw driver , filter , thermostatic expansion valve , high pressure switch cutout , oil pressure switch cutout , v belts to interconnect compressor and motor pulley , thermostatic expansion valve complete on plant , lpointppointcut out , forced air cooling unit fintex eqvt make for cold room , shock mounts for compressor , dial type thermometers , gasket 0point3mm , split pin , coil defrost heater brass tublar , back pressure valve , connecting rod bush , bearing bushing 0point25mm , sdnr valve 65 mm , v belt b70 , charging line , motor protection relay , adjustable spanner 8 inch , 8 amp hrc fuse , liquid line filter drier , voltmeter 0 500 v , pipe wrench
Tender For bid to ras supply of spare part - gasket blanking plate , gasket , ring retaining , riing rubber o , pin , gasket jocky pully , retainer gasket , gasket aerator , pin master , washer , clamp hose , nut , connector fuel drain , nut cross head , spring , cock drain , ring rubber o , seal cap filter , bolt , seal , o ring , screw cross head , connection fuel inlet , elbow on bypass filter , gasket exhaust manifold , tube fuel supply , clamp , element filter , screen lub oil section , starter switch , screen filter , o ring cover , manifold fuel supply , gasket housing to block , element corrision resister , blanking plate , thermostat , belt fan , manifold fuel drain , gasket exhaust front , cover fuel pump , hose fuel tank to water separator , hose water separator to fuel filter , cap assy , screen , trank line assy , bucket cylinder head end hose , arm cylinder seal kit , bush lift cylinder , fan belt vee ribbed , suction hose hyd pump , hand pump seal kit , flat face coupling set , fuel filter cartridge , element lub oil filter , air filter element outer , nut lock