Web Analytics Made Easy - StatCounter

Changeover Panel Tenders

Get complete information related to latest Changeover Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Changeover Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Changeover Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40950683 Due date: 15 Jul, 202515 Jul, 2025 22.31 Lacs
Tender For camc including consumables, repairs and replacement of defective parts of 1000 lpm ogp along with allied electro mechanical equipments along with operational charges for 01 year at gmc ah rajouri - comprehensive annual maintenance (camc) camc of oxygen generation plant ( airsep make 1000 lpm complete unit) which includes periodic servicing/maintenance and repairs of complete ogp unit (consisting of oxygen modules, air compressors (110 kw ingersoll rand make, air dryers (trident make), filtration assemblies, air tanks, oxygen tanks, interconnecting pipeline, control valves, indicators, sensors, pressure & purity meters, ups, electric panel, valve panel, and other allied accessories, etc.), (including topping/replacement of molecular sieve (zeolite/alumina/any other chemical as per requirement), copper pipeline from plant room upto patient beds, allied equipments such as main 630 amp. electric distribution cum changeover panel, mccbs/acbs, 400 kva avr (ae make), 250 kva avr (jaima make), 400 kva dg set sudhir power make (including replacement of batteries), amf panel, cabling, lightening arrestor, earthing, etc., other miscellaneous items of the plant room such as lighting, exhaust fans, ceiling fans, cctvs with inverter battery set, electric wiring and fittings, refilling of abc type fire extinguishers, other minor civil items, etc. the job also includes repair/replacement of defective pipeline from air compressors to air tanks/air dryers to psa tower in order to make it leak proof.the technicians for operation will be responsible for preventive maintenance, minor repairs/settings on a routine basis. major breakdowns of the plant equipment to be repaired by the firm through oems/open market workshops, etc. for maintaining the plant in working condition the firm will bear all charges of material including consumables, labour, transportation and all taxes as applicable.any other item of the oxygen plant not mentioned in the above description, but found necessary for the functioning of the plant, is deemed to be covered under the oc/camc contractfirst year, second year, third year, fourth year, fifth year, sixth year, seventh year, operational contract (oc)24x7 operation of 1000 lpm psa oxygen generation plant ( airsep make complete unit) and it s all allied equipments including power backup. the technicians for operation will also be responsible for preventive maintenance, minor repairs/settings on a routine basis. wages of the operators/technicians (3 nos + 1 no) for 01 year (12 months) having experience of similar work.first year, second year, third year, fourth year, fifth year, sixth year, seventh year

Central Government / Public Sector

CTN :38327953 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For bid to ras bid to ras corrigendum : supply of hot standby mv vfd along with auto changeover panel and output circuit breaker , supervision charges for installation , manday charges for pm/emeregncy visits

State Government

CTN :40865250 Due date: 02 Jul, 202502 Jul, 2025 88.61 Lacs
Tender For providing bypass changeover panel for 4x300 kva ups system at rgss hospital tahirpur delhi 110093

State Government

CTN :40756934 Due date: 02 Jul, 202502 Jul, 2025 10.04 Lacs
Tender For supply and installation of some articles to the residential office of the honble deputy speaker, tripura legislative assembly, bardowali, agartala during the year 2025-26 - providing of split type high wall 2.00 tr (rated cooling capacity should not be less than 6,000 kcal/hr or 24000 btu/hr or 7000 kw) split a.c. machine with inverter compressor technology operating on non-cfc refrigerant (r-410a/r-32/equivalent refrigerants) suitable for wall mounting conforming to is:1391 (part-ii) specification (evaporator & condenser must be of pure copper) not less than 3 (three) star rating (latest standard), operates on single phase 230 volt, 50hz, ac supply maximum current drawn 11.0 ampere, including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (four) core electrical connecting cable, remote control unit in/c batteries, 16 amps power top etc complete, capable of performing a) cooling b) dehumidifying c) air circulation d) filtering as per direction of the engineer-in-charge., standard installation of 1.5 tr/2.00 tr capacity high wall split air conditioner i/c providing of electrical plug top of required capacity, flling up/ repairing of drilled portions by cement mortar, painting etc. as per direction of the engineer-in-charge., fabrication of m.s. platform for placement of condensing unit by using m.s. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the engineer-in-charge., providing hard pvc pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the engineer-in-charge., supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 tr & 2 tr ac) beyond the standard length as per direction of the engineer-in-charge. (if required), providing and connecting electric control cables between mcb to indoor/outdoor. 3c x 2.5 sq. mm copper cable., supplying & fixing of 1200 mm sweep white color ac ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm pvc insulated copper conductor cable(fr) (isi marked, bee 1 star/minimum service value 4.0 m /min/w): -, supplying and fixing of 20 mm dia extra down rod (gi pipe medium guage) with necessary hole for installation of ceiling fan as required., wiring for light/fan/ exhaust fan/ call bell point with 2x1.5 sq. mm pvc insulated copper conductor cable (fr) in pvc conduit (medium gauge) recessed in slab/ walt complete with 6/10 amps modular type switch, cover plate, gl box including necessary connection etc. as required, supplying and fixing of the following modular accessories including necessary connection etc. as required 3/6 pin 16/20 amps socket outlet (2m), supplying and fixing of the following modular accessories including necessary connection etc. as required4 step fan regulator (1m), supplying and fixing of the following modular accessories including necessary connection etc. as required20/25 amps single phase motor starter switch (2m), wiring for circuit/sub-main with the following sizes pvc insulated copper conductor cable (fr) in pvc conduit (medium gauge) recessed in slab/ wall etc. as required, earthing with 40 mm dia g.i. earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top cl cover plate size 12"x 12" having locking arrangement including cc work, holes on earth pipe etc. as required, proving and fixing/drawing of 4.06 mm dia (8 swg) g.i. 10 wire on surface or in existing g.j/pvc/ polythene pipe for loop earthing as required., executive desk with return unit, size: 2100(w)x 2250(d) x 750 (h) mm, executive revolving chair, visitor chair, godrej 4 door bookcase (1742 h x 914 wx 320 d) mm
 Loading, Please wait...

Connect us via What's Up