Web Analytics Made Easy - StatCounter

Changeover Switch Tenders

Get complete information related to latest Changeover Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Changeover Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Changeover Switch Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :38565397 Due date: 23 Dec, 202423 Dec, 2024 75.0 Thousand
Tender For replacement of on load changeover switch, of 150 kva voltage stabilizer along with other electro mech. parts at lis dharap.

CTN :38602151 Due date: 26 Dec, 202426 Dec, 2024 NA
Tender For supply of changeover switch disconnetcor 3 phase 4 pole 400 amp with steel enclosure

CTN :38601387 Due date: 06 Jan, 202506 Jan, 2025 NA
Tender For supply of repair of engagement light-installation and shifting of engagement light , repair of engagement light-connection switch , repair of engagement light-change of copper wire , repair of engagement light-supply and fixing of zero watt bulb , repair of engagement light-supply and fixing of gang box with switch , repair of call bell-change of copper wire 3/2 core , repair of call bell-connection switches etc , repair of call bell-supply and fixing of push switch , repair of call bell-installation and shifting of call bell , repair of call bell-supply and fixing of gang box with switches , repair of electric kettle-change of wire , repair of electric kettle- change of adaptor and socket , repair of electric kettle- change of heating element , repair of electric kettle- change of handle , repair of food warmer-supply and fixing of plug , repair of food warmer-supply and fixing of element , repair of food warmer-supply and fixing of indicator , repair of food warmer-supply and fixing of glass , repair of food warmer-supply and fixing of wire , repair of food warmer-supply and fixing of temperature knob , repair of food warmer-supply and fixing of thermostat , repair of extn board-change of fuse , repair of extn board-supply and fixing of switch (anchor) 5/15 amp , repair of extn board-supply and fixing of indicator anchor lamp , repair of extn board-only repair including connection and the box , repair of extn board-change of wire , repair of extn board-supply and fixing of 5amp anchor socket , repair of extn board-change of plug , repair of extn board-supply and fixing of 15amp anchor socket , repair of room heater-supply and fixing of filament rod , repair of room heater-supply and fixing of reflector , repair of room heater-supply and fixing of grill , repair of room heater-change of wire , repair of room heater-change of plug , repair of room heater-change of sleeves , repair of heat convector- fitment of plug , repair of heat convector- fitment of fan blower , repair of heat convector- change of motor , repair of heat convector- change of switch , repair of heat convector- change of thermostat , repair of heat convector- change of element , repair of heat convector- change of chord , repair of heat convector- change of indicator , repair of heat convector- change of handle , repair of otg , repair of induction cooktop , repair of microwave oven , repair of oil heater , repair of engagement light change of gloves/glass cover full , repair of electric kettle-change of plug

Central Government/Public Sector

CTN :38569509 Due date: 24 Dec, 202424 Dec, 2024 NA
Tender For on load changeover switch unit i-o-ii, 400 amps four pole front operated handle operation with sheet steel enclosure duly powder coated suita ble for 3 phase 415 volts 50 hz ac supply and duty as per utilization category ac-23a. confirm to is/iec 60947 -3 or latest. warranty : 2 years [ warranty pe riod: 24 months after the date of delivery ]

Central Government / Public Sector

CTN :38589294 Due date: 27 Dec, 202427 Dec, 2024 NA
Tender For supply of supply of 26 tr precision air conditioniner,sitc of automatic changeover switch,sitc of cu refrigerant pipe,sitc of condensate drain pipe,sitc of 4c x 25 sq,mm cu armoured,sitc of 3c x 2,5 sq,mm cu armoured,sitc of r 410a gas charging for all pac,sitc of ms stand for indoor and outdoor,sitc of humidifier water pipe,sitc of humidifier water inlet valve,sitc of cable tray with cover for cu pip,supply and fixing of plastic emulsion paint,making opening in walls for services,supply and fixing of fire rated bison board,supply and fixing of thick glass wool,supply and fixing of ms partition frame,supply and fixing of fire rated window,supply and fixing of exhaust gril alumin,removing of existing fire glass door,removing the sliding folding partition,supply and fixing of grid ceiling reparing,removing ac grill at side including squa,post warranty camc,1st year,post warranty camc,2nd year,post warranty camc,3rd year,post warranty camc,4th year

CTN :38554736 Due date: 02 Jan, 202502 Jan, 2025 NA
Tender For supply of halogen light led , change over 100 amp , dustbin 50ltrs , changeover switch 100 amp box type , mccb 100 amp 4 pole 25ka with sp link , mcb 20 amp 1 pole , 2 core 10mm cable , mcb box 200 amp , pvc wire 4mm copper

Central Government/Public Sector

CTN :38531458 Due date: 30 Dec, 202430 Dec, 2024 10.00 Lacs
Tender For repair/ replacement of unsv ug cable, mccb, changeover switches etc in chennai area under age(i) navy chennai

Private Sector

CTN :38546216 Due date: 03 Jan, 202503 Jan, 2025 NA
Tender For supply of onload changeover switch disconnector for metering unit

CTN :38533337 Due date: 31 Dec, 202431 Dec, 2024 NA
Tender For supply of overhauling of dynamo with replacement of armature,replacement of hood complete and repair driver seat and back rest complete with foam cover and cushion,replacement of hour meter and temperature meter,replacement of king pin with bush,replacement of fuel pump and filter,removal of complete dent of whole body and og painting with polishing and marking of number plate,replacement of silencer assembly,overhauling of lift system,repair of radiator assembly by repairing damage tubes by gas welding and cleaning of radiator and soldering of top and bottom of radiator,replacement of radiator fan and fan belt,replacement of head light reflector including 2 bulb and checking of electrical wiring system,replacement of ignition switch assembly,greasing of four wheel and replacement of oil seal,replacement of clutch plate and pressure plate assembly

Central Government/Public Sector

CTN :38157116 Due date: 27 Dec, 202427 Dec, 2024 1.30 Crore
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous
 Loading, Please wait...

Connect us via What's Up