Web Analytics Made Easy - StatCounter

Chip Resistor Tenders

Get complete information related to latest Chip Resistor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Chip Resistor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Chip Resistor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39442342 Due date: 20 Mar, 202520 Mar, 2025 NA
Tender For supply of developmental tender of roof line insulator.

Central Government/Public Sector

CTN :38966011 Due date: 28 Feb, 202528 Feb, 2025 53.05 Lacs
Tender For corrigendum : supply of aaa insulated conductor size 7 by4.39mm pvc insulated , gi c-type channel 75mmx40mmx10mm x3metre , gi f- cross arm , gi v-cross arm , pin insulator 11 kv , disc insulator 11 kv , gi stay set ht suitable for 11kv line , gi earthing electrode pipe 40 mm dia , gi clamp as per drwg 93 sl no-1 , gi clamp as per drwg 93 sl no-2 , gi clamp as per drwg 93 sl no-3 , gi clamp as per drwg 93 sl no-4 , gi clamp as per drwg 93 sl no-5 , gi nut and bolt ft with 2 plain washers m16x75mm , gi nut and bolt ft with 2 plain washers m16x100mm , gi nut and bolt ft with 2 plain washers m16x150mm , gi nut and bolt ft with 2 plain washers m16x200mm , gi nut and bolt ft with 2 plain washers m16x250mm , rcc pole 9 mtr , cable route marker , silica gel blue 9-12 mm size with air tight container , petroleum gelly

State Government

CTN :39136972 Due date: 27 Feb, 202527 Feb, 2025 NA
Tender For corrigendum : tender for supply of equipment design erection tetsing and commissioning for sop to 4g bsnl tower authority by providing single phase lt line at lagga chalga along with augmentation of existing dtr under esd chamba no ii - supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, supply of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, erection of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, mannual carriage of existing & new transf.(25 & 63 kva) 2.00 km back to store, supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96 /24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint

Central Government/Public Sector

CTN :39384642 Due date: 05 Mar, 202505 Mar, 2025 NA
Tender For supply of bolt hex cs ht , flodlght , bottle vacuum , cntctr 16a , relay ovrld , arrester , relay master trip , tester ht line , separator , insulator pin , insulator shackle , insulator stay lt , clamp wre rpe

State Government

CTN :39400371 Due date: 06 Mar, 202506 Mar, 2025 25.36 Lacs
Tender For dismantling of existing porcelain lightening arrestors, surge counters, cvts, acsr conductor, supporting porcelain insulators, supporting structures, complete form line side insulator to takeoff tower for 66kv shimoga bhadra lines 1, 66kv shimoga bhadra lines 2 and lh transmission lines.2)2)supply, erection, testing and commissioning of 3 nos. of 66kv transmission line equipments like cvts, polymeric lightening arrestors with surge counters, supporting polymeric insulator stacks, lynx acsr conductor, clamps, connectors, structure etc. complete from line side isolator to take off tower of 66kv transmission line equipments from line side isolator to take off tower at bhadra generating station.3.dismantling of existing 72.5kv, 0.5cl current transformers, supply, erection, testing and commissioning of 0.2 class, 72.5kv current transformers for 12mw river bed units 1 and 2 at bgs.4.supply of essential spare 04 nos. of 66kv polymeric insulator stack and 01 no. of 0.2cl 72.5kv current transformer.5.jungle clearance along the lines wherever necessary.6.the scope also includes testing at works before dispatch, pre-commissioning and commissioning tests at site and the performance guarantee tests in respect of 72.5kv cts, 60kv las, 72.5kv cvts required for bhadra generating station.7.the scope of supply shall include all accessories, marshalling box, terminal connectors, wedges, clamps, supporting structure etc., which are necessary for assembly and erection of ct, cvt & la.8.modifications required for foundation and support structures to erect newly supplied cts, cvts and las shall be carried out by contractor at no extra cost.

Central Government/Public Sector

CTN :39031785 Due date: 24 Feb, 202524 Feb, 2025 97.00 Lacs
Tender For corrigendum : certain maintenance work under ge east jabalpur - m & l for painting carefully (by taking necessary shut down from respective sub-station) on steel tubular poles 9 m high from (above grnd 7.5rm) upto top of the pole, including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality aluminium paint after preparation of surface by wire brush and painting with two coats of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing pole no. of suitable size of letters as directed. note : size of lettering and colours of paints will be directed by engr-in-charge., m & l for painting carefully (by taking necessary shut down from respective sub-station) on lt pcc pole 9 m high from (7.5 metre above natural ground ) upto top of the pole, applying two coats of cement base paint over a coat of alkalines resistant primer to surface of concrete pole with cement based paint after preparation of surfaces of poles including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing pole no. of suitable size of letters as directed. note : size of lettering and colours of paints will be as directed by engr-in-charge., diasmantling of acsr or aac conductors of any size from lt poles or distrubution span of complete all as specified & directed., fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of aacsr/aac/lt over head conductors of any size with and including 14 swg binding wire and testing, complete all as specified & directed., m&l for acsr conductor lt (6 in 1) weasel type ,restringing and fixing it properly in between poles and connecteing it with insulator properly all as per required and directed by engg in chrge, dismantling gi wire of any size from lt poles or distribution span & removal from site, complete all as specified and directed., fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of galvanised steel wire 3.15 or 4 mm dia lt over head earth wire, complete all as specified & directed., m&l for over head galvanised steel wire 3.15 or 4mm dia on existing lt poles and stretching and then strengthening including binding & jointing the conductor and testing complete all as specified and directed., m & l for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with m.s. clamps, bolts and nuts of approved size, for lt, 20x15cm size complete all as specified and directed., dismantling old unserviceable insulators of any type including ms spindles, gi washers, nuts etc and s&f shackle type, porcelain, vitreous, white/brown or green insulator including galvanised mild steel straps(31x5mm), two gi washers & one gi nut, 100 mm height and 115 mm dia(max) suitable for working pressure 1100 volts grade, complete all as specified and directed., s&f pvc separator 2 way for lt overhead electric line complete all as specified and directed., s&f pvc separator 4 way for lt overhead electric line complete all as specified and directed., supply and fix, erection steel tubular swaged poles type 410 sp-31 (9 meter long), painting with two coat of aluminium paint over one coat of red oxide primer and marking pole nos with black sythetic enamelled paint including tarring one coat of steel surface embedded in concrete complete excluding earth work and pcc work and taking out old unserviceable lt pole complete all as specified and as directed., dismantling lt steel tubular poles and setting aside for re-use within 50 metres complete all as specified

Central Government/Public Sector

CTN :39357358 Due date: 25 Feb, 202525 Feb, 2025 87.86 Lacs
Tender For supply of mine line make spares for different equipments - cover bolts , isolator assembly k3 on off , isolatorassembly k4 on off 300a , mounting bar for isolator , coilspring for isolator up to 400a , isolator micro switch assly ,catcher assembly , arc chutes , ammeter100 5 for acb ,ammeter 200 5 for acb , ammeter 300 5 for acb ,ammeter 400 5 for acb , push button actuator for el test ,push button actuator for el reset , potential transformer ,incoming gland , outgoing gland , glass fuse with holder ,power cable for 300a for breaker chamber ic og set ,power cable for 400a for breaker chamber ic og set ,power cable for 200a for breaker chamber ic og set , limitswitch 2no 2nc for breaker , brass terminal , push buttonwith spindle , brass terminal for cp , earth leakage relay50 750m a with time lag with cbct , moving contract forisolator , overload assembly breaker 30a 100a , overloadassembly breaker 110a 200a , overload coil 200 a , movingcontact for breaker upto 200 amps , moving contact forbreaker 400 amps , shunt trip assly complete. , no volt coilassy. under voltage coil assy. without moulding , no voltcoil assy. under voltage coil assy. with moulding , currenttransformer for ammeter , busbar , indicating lamps ,moving contact finger 400a , fixed contact assy. forbreaker , operating handle for isolator , terminal bushingwith insulator dmc incoming 6mm 20mm , terminal bushingwith insulator dmc incoming 8mm 20mm , fixed contactassy. for isolator 400a , overload assembly breaker 310a400a , arc chutes pillar , fixed contact breaker , potentialtransformer 80v , overload assembly breaker 210a-300a ,limit switch no nc for breaker , on off isolator 300a ,rectifier , ht bushing with stud. 3.3kv , reveering isolator3.3kv , ht rec pt fuse , p fuse plate wiring ass. , ht fusesupport base eppxy cast , aux. transformor single phase , support base eppxy cast , aux. transformor single phase , voltmeter selector switch , potential transformor ,isolator handle , off delay timer , incoming throughgoing sealing box with cone and gland assy , outgoingterminal swaling box with cine gland 3 way , copperterminals with dmc bushing , brass terminal with dmcbushing , brass terminal with nylon bushing , isolatorhandle , on off isolator 100a , glass fuse with holder , noactuator , nc actuator , relay coil voltage 2co contact ,pot. transformer , push button with spindle , actuator nonc , hrc fuse 16a , hrc fuse 63a , sensitive earthleakage relay 50 300ma with variable time lag , indicatingled , body bolt , ammmeter , core blancetransformer , thermal overloderelay with block , isolatork3 on off , thermal ol relay ctr 50 5 range 20a 50a ,ammeter 120 5 for lt starter , on delay timer , potentialtransforiner , aux, contactor220v ac , glass fuse withholder , potential transformer 80 va , sensitive earthleakage relay 50 300ma with variable time lag with controltransformer and suitable cbct , pilot relay , brassterminal with dmc bushing , brass stud with dmcbushing for og , hrc power fuse , isolator handle ,thermal o l relay ctr 120 5 range 48a 120a , off delaytimer , aux. relay 220v ac coll 3co base , multi pilot relay12.5 dc , single phasing preventer current operated ,single pole two way toggle switch , actuator no , actuatornc , push button element , isolator on oft rov 300aa ,isolator 3p on off 100a , indicating lamp , potentialtransformer , ht bushing , control relay 110v , dcpower pack , hcr ht pt fuse 3.3kv , pct transformer, aux contractor , natutral earthing resistor , vcbclosing coil , vcb shunt trip coil , vacuuminterrupter , neutral monitoring relay withresistance , earth leakage 5 750 ma and 750 ma 2 a dualsetting with time lag with cbct , 3 pole oil dashpot relay300 5 , dc power pack , vcb limit sweitch , hv bushuing ,isolator , current transformer , vcb shunt trip coil , controlrelay , capictor trip device , vaccum circuit breaker , pottransformer 500va , indicating lamp , contrtol fuse , undervoltage r...

CTN :39332949 Due date: 27 Feb, 202527 Feb, 2025 NA
Tender For e-tender :- work of cleaning of insulator string by cold line chemical washing of various 400 kv lines under jurisdicion of 400 kv r.s division lamboti

Central Government/Public Sector

CTN :39350010 Due date: 17 Mar, 202517 Mar, 2025 NA
Tender For supply of roof line supporting insulator conforming to clw specn no.clw/es/ac/i-1 alt-k and clw drg. no.clw/es/sk-2/ac/i-1 alt-k . [ wa rranty period: 30 months after the date of delivery ]

Central Government / Public Sector

CTN :39350732 Due date: 07 Mar, 202507 Mar, 2025 NA
Tender For supply of panto foot (mounting) insulator for locos & emus/memus and roof line insulator for emus/memus as per clw's specn. no. cl w/es/ac/i-1/k and clw's drg. no. clw/es/sk-4/ac/i-1/k. [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up