Get complete information related to latest Chokes Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Chokes Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Chokes Tenders.
Tender For supply of set of chokes l1 & l2 suitable for 25 kw pd steel make rrus as per pd steel part no. pdsr25009 & rdso specification no: r dso/pe/spec/ac/0056-2014(rev-1). make: pd steel. [ warranty period: 30 months after the date of delivery ]
Tender For supply of set of application & release chokes for keo type dv of bvzi/bvzc wagons to escorts par t no. 178 & 177 or knorr-bremse part no. a31259/17/ki & a31657/13/ki, conforming to rdso specificatio n no. 02-abr-02 with amendment. no. 4 of september 2016 and appendix-a1 & a2 [ warranty period: 36 m onths after the date of delivery ]
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi
Tender For supply and installation of electric material of isi mark in the jurisdiction of jda division no.ii. - led tube light fitting complete 18 watt. 4, led tube light fitting complete 28 watt. 4, ignitior 70 - 400 watt for sodium light, electronic chokes for 36 watt fittings 4 long, led tube light 36 watt 4 complete fitting, starter for tube light, capacitor 10 m.f. for s.v. fittings, capacitor 4 m.f. for coolers, capacitor 3.25 m.f. for c. fan, capacitor 3.5 m.f. for e.fan, capacitor 2.25 m.f. for w.fan, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. socket 5/6 amp piano type, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required switch 5/6 amp piano type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. socket 5/6 amp modular type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. switch 5/6 amp modular type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. socket 15/16 amp modular type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. switch 15/16 amp modular type, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. socket 15 amp piano type, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. switch 15 amp piano type, combine 15 amps switch & socket with gang box, led blub 5 watts., led blub 9 watts, led blub 15 watts, led blub 20 watts, led blub 40 watts, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. m.c.b. 240/415 volt s/pole 6-32 amps, supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. m.c.b. 240/415 volt s/pole 40 amps, s.p.n. 40 amps 240 volts., supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections,testing and commissioning etc. as required. s.p.n. 63 amps 240 volts., supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. t.p.n.. 25 amps 415 volts., supplying and fixing following rating, four pole, (three phaseal), 415 volts, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required t.p.n.. 40 amps 415 volts., supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. t.p.n.. 63 amps 415 volts., m.c.c.b. (4 poles) 63 amps 35k, m.c.c.b. (4 poles) 100 amps 35k, m.c.c.b. (4 poles) 200 amps 35k, m.c.c.b. (4 poles) 250 amps 35k, m.c.c.b. (4 poles) 400 amps 35k, m.c.c.b. (4 poles) 630 amps 50k, m.c.c.b. (4 poles) 800 amps 50k, industrial socket for 240 volts, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recess