Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- koti(imlidand,khaspara,korwapara) koti(panditpara) koti (daridih, pateratola, purankoti) block- wadrafnagar district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 840 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 550 m., 75 mm dia. 1000 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 0 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village-koti(imlidand,khaspara,korwapara)koti(panditpara) koti(daridih,pateratola,purankoti) block- wadrafnagar district – balrampur(c.g.)
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 00 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 1300 m., 75 mm dia. 127 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 46 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)
Tender For bhoj dharti,bhoj darara,bhoj mataur, group of 3 no. of habitations annual mtc.works for water supply - demolishing dry brick pitching in floors, drains etc, providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering, steel reinforcement for r.c.c. work, brick work with common burnt clay modular bricks of class. cement plaster.
Tender For corrigendum : e-tender for civil contract jobs - civil contract job:, earth filling under floors with surplus ordinary soil or soil containing gravel or kankar, including ramming, watering and consolidated lead., first class burnt brick work laid in cement sand mortar 1:7 in foundation and plinth, laying 80 mm thick factory made cement conc. inter locking paver bricks after m-40 grade made by block making machine with string vibratory compaction ordinary gray color & pattern over 50 mm thick compacted bed of coarse sand filling the joint with fine sand, complete in all respect ., dismantling brick of flagged stone flooring including concrete base, dismantling concrete plain 1:2:4 mix, cement concrete 1:2:4 with stone ballast or shingle, a. mixing by manual mean, b. mixing by mechanically mean using concrete mixer, laying of dry brick ballast 40mm gauge for flooring, civil work (rate to quoted on csr rates)
Tender For bid to ras supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , supply and fixing on load change over switch ss enclosure complete with capacity 200 amp, 415 volt, 4 pole, 50 hz. , supply and fixing sheet metal enclosure spn db double door having facility to fix mcb spn as incomer and mcbs as outgoing, spn 4 ways, ip-43 , supply and fixing sheet metal enclosure tpn db double door having facility to fix mcb tpn as incommer and mcbs as outgoing tpn 4 ways, ip-43 , supply and fixing bus bar chamber 100 amp, 4 way, 415 volts enclosurre is made from crca sheet of thickness 3.15mm crca sheet cover , supply and fixing of straight through epoxy cable joint kit incl jointing materials making joints of ug electric cable 1100 v grade nominal cross sectional area not exc.50 sqmm, 3.5 by 4 core , supply and fixing straight through epoxy cable joint kit incl jointing materials making joints of ug electric cable 1100 v grade cross sectional area 240 sqmm to 300 sqmm, 3.5 core. , supply and fixing end termination epoxy cable joint kit including jointing materials for making joints of ug electric cable 1100 v grade nominal cross sectional area 240 sqmm to 300 sqmm, 3.5 core , supply and fixing of galvanised iron pipe 100 mm bore dia light grade for protection of ug cable , supply of digging nad layingg in excavation trenches not exc. 1.50 m wide and not exc. 1.50 m in depth, complete all as specified and directed. , returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft loose soil , supply and fixing of galvanised iron pipe 40 mm bore dia light grade for protection of ug cable , supply, installation, commissioning and testing including providing all necessary electrical connection,lt feeder panel board of size 1.0 m x 0.6 m x ) /bid number : gem/2026/b/7568567 * /dated: 22-05-2026 & & / bid document 1 / 30 & & ' ' /item category 0.5 m , supply, installation, commissioning and testing including providing all necessary electrical connections lt feeder panel board of size 0.6 m x 0.6 m x 0.5 m , supply and fixing earhing complete with gi earth plate electrode of size 600x600x6mm thick.complete all as specified and directed in boq spec file , supply and fixing earhing complete with gi earth plate electrode of size 600x600x6mm thick. complete all as specified and directed in boq spec file , supply and fixing of sub-class b brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for ug cable protection, complete all as specified and directed. , supply and fixing horizontal boring under a depth of 0.65 m from the gl for passing pipe upto 40 mm bore dia , supply of digging and laying of removing excavated materials soils not exc. 50 m and depositing where directed at a level not exc.1.50 m , taking down out unserviceable or serviceable lt ug cables of nominal cross-sectional area 300 sqmm including bricks, gi pipes etc. , taking down out unserviceable or serviceable lt ug cables of nominal cross-sectional area 50 sqmm 3.5 core including bricks, gi pipes etc. , supply of digging and laying of sand cushioning dry in trenches for protection of ug cables below, above and around the ug cable laid in trenches of 230 mm spread thickness , cutting road by hard standing and making good disturbed surfaces by using pcc type-c2,1-3-6 by using 40 mm graded stone aggregate , boring of holes under road,pavement,hard standing by trenchless technology using ultra sounding technique including hdpe pipe 150 mm dia suitable for 0.4 mpa working pressure , cutting chases, chipping in making good to facings, where required and pointing in cement mortar 1- 3 to ends or edges of landings, steps, sills, sunshades, shelves, lintels etc. , submain wiring comprising single core 2 runs of 6 sqmm nominal coss sectional area frlh
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with is : 5382 and testing of spigot and socketted rcc, np2 marked with is : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the engineer - in -charge. 4. 350 mm i/d ,`jointing plain and reinforced concrete pipes and specials of all classes in trenches using collar joints jointed with 1:1 cement sand mortar nearly dry heavily caulked into joints and with end dowels filled with 1:1 cement sand mortar including facing trowelling and finishing the joints at an angle of 45 degrees with faces of collars keeping joints wet till curved testing the drain lines for leakage and making good all leakage and defects as laid down in the contract specifications complete with two spigot ends jointed to collar and internal diameter of sewer pipe or special , earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by engineer-in-charge. 1. all kinds of soil ,cement concrete (cast in situ) providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level and up to floor iv level: 3. 1:2:4 (1 cement : 2 coarse sand (zone-iii) : 4 graded stone aggregate 40 mm nominal size),brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. cement mortar 1:6 (1 cement : 6 coarse sand), cement plaster (in fine sand) 12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand)
Tender For brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. cement mortar 1:4 (1 cement : 4 coarse sand) ,lan and reinforced concrete pipes `jointing plain and reinforced concrete pipes and specials of all classes in trenches using collar joints jointed with 1:1 cement sand mortar nearly dry heavily caulked into joints and with end dowels filled with 1:1 cement sand mortar including facing trowelling and finishing the joints at an angle of 45 degrees with faces of collars keeping joints wet till curved testing the drain lines for leakage and making good all leakage and defects as laid down in the contract specifications complete with two spigot ends jointed to collar and internal diameter of sewer pipe or special being. ` 7. 350 mm internal diametre sewer pipe
Tender For brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. cement mortar 1:4 (1 cement : 4 coarse sand) ,lan and reinforced concrete pipes `jointing plain and reinforced concrete pipes and specials of all classes in trenches using collar joints jointed with 1:1 cement sand mortar nearly dry heavily caulked into joints and with end dowels filled with 1:1 cement sand mortar including facing trowelling and finishing the joints at an angle of 45 degrees with faces of collars keeping joints wet till curved testing the drain lines for leakage and making good all leakage and defects as laid down in the contract specifications complete with two spigot ends jointed to collar and internal diameter of sewer pipe or special being. ` 7. 350 mm internal diametre sewer pipe