Web Analytics Made Easy - StatCounter

Ci Roll Tenders

Get complete information related to latest Ci Roll Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ci Roll Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ci Roll Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :42998560 Due date: 08 Dec, 202508 Dec, 2025 4.61 Lacs
Tender For supply of butterfly valve body and vane castings in cf8m grade material on rate per kg basis

Central Government/Public Sector

CTN :42998614 Due date: 08 Dec, 202508 Dec, 2025 NA
Tender For supply of butterfly valve body and vane castings in cf8m grade material on rate per kg basis - manufacturing and supply of butterfly valve body and vane castings in cf8m grade material on rate per kg basis

Central Government/Public Sector

CTN :42901713 Due date: 03 Dec, 202503 Dec, 2025 NA
Tender For corrigendum : supply of castings

Central Government/Public Sector

CTN :42707290 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For corrigendum : providing of custom bid for services - inspection service of gamma radiographic inspection of titanium castings

Central Government/Public Sector

CTN :42421494 Due date: 25 Dec, 202525 Dec, 2025 NA
Tender For corrigendum : tender for supply of supply of titanium alloy castings by using hal provided technologies and raw materials e e - casing , cover , casing , front ring , adapter , ring , ring , adapter , upper ring , flange drives , cover , casing of suspension , cover , bracket , ring , fork , valve seat , bracket , adapter

Central Government/Public Sector

CTN :42452714 Due date: 25 Dec, 202525 Dec, 2025 NA
Tender For corrigendum : tender for supply of supply of steel alloy castings as per hal technology e e - hyd cyl bracket , bearing casing , casing , plate , cover , bracket , bracket , casing , arm , hyd cyl bracket , branch pipe , angle bar , barostat casing , bracket , bracket , nozzle , bush , flange , elbow , valve casing , arm , bracket , bracket , bracket , branch pipe , bracket , casing , casing , casing , branch pipe , bracket , bracket , sector , branch pipe , bracket , bracket , valve , casing

Central Government/Public Sector

CTN :42476930 Due date: 25 Dec, 202525 Dec, 2025 NA
Tender For corrigendum : tender for supply of supply of nickel alloy castings as per technology provided by hal e e - t-piece joint , valve body , casing , bush , bracket , bracket , bush , bracket , branch pipe , air swirler , hpt insert , plate , casing , bracket , cover , support , support , holder , sleeve , bracket , bush , cover , bracket , piston , sleeve , bush , bush , internal ring , flange , flange , flange

State Government

CTN :42295250 Due date: 04 Dec, 202504 Dec, 2025 NA
Tender For corrigendum : fabrication and erection of red spot patch up box in cooler, dbc preheater castings, meal pipe, ducts, chutes at preheater at cement plant.

Central Government/Public Sector

CTN :42956361 Due date: 26 Dec, 202526 Dec, 2025 61.87 Lacs
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi
 Loading, Please wait...

Connect us via What's Up