Get complete information related to latest Circuit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Circuit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Circuit Tenders.
Tender For supply erection testing and commissioning of stringing of second circuit on 132kv yemmiganur-madhvaram dc/sc line with acsr panther conductor (26.8km) and 01no. new 132kv bay extension at 132kv ss madhavaram and 01no. new 132kv bay extension at 132kv yemmiganur in kurnool district
Tender For corrigendum : supply of electrical plugs (v2) isi marked to is 1293,dol starter,non - modular piano type domestic electrical switches as per is 3854,non - modular piano type domestic electrical switches as per is 3854,piano type non modular domestic electrical sockets - is 1293,piano type non modular domestic electrical sockets - is 1293,mcb - miniature circuit - breakers for a.c. operation as per is / iec 60898 (part 1),piano type non modular domestic fan regulator as per is 11037,fixed capacitors (fixed capacitor for single phase ac electric fan) as per is 1709:1984
Tender For supply of miniature circuit breaker mcb for hot case, current rating 10 amp yoltage rating:230v ac,curve -c ,pole:2p,breaking capacity :10ka as per bill of material of rdso specification no.rdso/pe/spec ac/0184-2015(rev.0) [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : tender for supply of equipment design erection tetsing and commissioning for sop to 4g bsnl tower authority by providing single phase lt line at lagga chalga along with augmentation of existing dtr under esd chamba no ii - supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, supply of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, erection of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, mannual carriage of existing & new transf.(25 & 63 kva) 2.00 km back to store, supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96 /24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint
Tender For bid to ras supply of fluid mechanics lab equipment - energy equation in convergent and divergent tube , horizontal flow from the tank , cavitation demonstrator , coefficient of discharge in notches , energy losses in piping elements with closes circuit water circulation , convergent and divergent flowmeter
Tender For supply of supplying of 1.5 tr wall mounting, non inverter type split air conditioner units with buyback as mentioned in boq sl.no.1 , supplying of 2 tr wall mounting, non inverter type split air conditioner units with buyback as mentioned in boq sl.no.2 , supplying of 4kva electronic voltage stabilizers for the 1.5 ton air conditioner as mentioned in boq sl.no.3 , supplying of 5kva electronic voltage stabilizers for the 2 ton air conditioner as mentioned in boq sl.no.4 , supplying and fixing of 0.75 inch heavy duty pvc drain pipe as mentioned in boq sl.no.5 , supplying and fixing of 0.375 inch air conditioner copper pipe with nitrile rubber insulation as mentioned in boq sl.no.6 , supplying and fixing of 0.625 inch air conditioner copper pipe with nitrile rubber insulation as mentioned in boq sl.no.7 , supplying and drawing 4c x 2.5 sq mm.flexible multicore cable manufactured with electrolytic grade flexible copper as mentioned in boq sl.no.8 , supply and fixing of 25a metal socket set of 2 pole and earth as mentioned in boq sl.no.9 , supplying and fixing 25 amps dp miniature circuit breakers as mentioned in boq sl.no.10 , supplying and fixing 20 amps dp miniature circuit breakers as mentioned in boq sl.no.11 , supplying and fixing of dp 2way enclosure box flush mounting as mentioned in boq sl.no.12 , core cutting as mentioned in boq sl.no.13 , supplying and fixing of outdoor air conditioners ms wall mounting ,floor mounting brackets as mentioned in boq sl.no.14 , installation testing and commissioning of new split air conditioner units as mentioned in boq sl.no.15 bid number/ & ( * ) : gem/2025/b/5849264 dated/ + : 05-02-2025 bid document/ 1 1 1 / 15