Tender For supply, installation, testing & commissioning (sitc) of 64 nos. sealed maintenance free (smf), valve regulated lead acid batteries (12 v, 75 ah) having fire retardant casing for centralised ups at reserve bank staff college (rbsc), chennai (date of nit available: july 07, 2025)
Tender For supply of rotary switch (change over programme with off) suitable for 63a/415v/ac/3pole/two positi on off, two position on, 90 degree apart with complete rotation, flag knob both mounting similar to salz er make cat no. 61153sib02tdyr and dimension as per dy.cee(w)/llh's drg. no. led/ac/3/887/type 2.(r otary switch should have fire retardant properties as per ul-94,v0 grade.) [ warranty period: 30 months after the date of delivery ]
Tender For special repairs replacement to e/m equipments and infrastructure at af stn jamnagar under ge (af) jamnagar no 1 - supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410 a/r-32 (b) eer- 5 star rating (c) tonnage - 1.5 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., supply, installation and testing air cooled inverter based split ac unit with cooling functions and suitable to operate at ambient conditions of (22 deg c + 3 in cooling mode) air conditoner will have following conditons :- (a) refrigerant - r-410a/r-32 (b) eer- 5 star rating (c) tonnage - 2 tr (d) indoor noise level - not more than 40 db (e) filter - as recommended by oem (f) remote - as recommended by oem including 02 nos remote bty (g) temp display, turbo mode and auto swing facility all specification will be as per is-1391 (part 2) and latest amendments as specified as directed by engineer-in-charge., note for item no 1 & 2 :- the cost of following items deemded to be included in quoted rate.(a) copper pipe duly insulated between indoor/outdoor unit upto lenght 10mtr for each unit (b) ms bracket for outdoor unit duly power coated with fixing arrangement.(c) making of hole in walls including civil work , sleeves and making good to the disturbed surface/wall.(d) testing and commissioning of the air conditioner to the entire satisfaction of engineer in charge(e) pvc round sheathed copper cable of suitable size for connecting indoor and outdoor unit upto supply point as per site requirement (f) taking down of existing ac and deposited to e/m store yard without any damage., supply and installation of voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input varioution between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 4 kva as specified as directed by engineer-in-charge., supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180v to 250v without voltage stabilzed at 230v with accuracy of (+) 2.5% and capacity 5 kva as specified as directed by engineer-in-charge., material & labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 sqmm each, pvc insulated, unsheathed, fire retardant, low smoke (frls) drawn through and including pvc casing capping with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.00 sqmm, pvc insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and as directed by engr-in-charge.note: 2 runs of main copper conductor, one run earth wire and pvc casing capping will be measured as one running meter for payment., s&f sheet metal enclosure , 20a single pole and neutral with a two pin and earth plug and socket complete in metal clad board (industrial type) with one single pole mcb 32 amp fixed properly on in concealed position all as specified as directed by engineer-in-charge., supply, installation, commissioning and testing in replacement of loop card having 254 devices of both detectors and modules in a single line circuit, slc supports both class a and class b wiring complete as specified and as directed by engineer-in-charge. make: ravel/honeywell/ceasefire industries pvt ltd, supply, installation, commissioning and testing in replacement of addressable smoke detector with base with binary coded address setting. dual leds for 360 visibil
Tender For supply of fire retardant low tension cotton insulation tape for electrical purpose in rolling stock co nforming to icf specification no.icf/elect/921 (rev-00) with cs-1,cs-2, cs-3 cs-4 with eastern railw ay monogram printed in english & hindi on non - adhesive side. colour in equal quantity red, yellow, b lue & black (roll length 10 mtrs). [ warranty period: 30 months after the date of delivery ]
Tender For supply of fire retardant upholstery cloth width 157 +/- 2 cm for lhb ac chair car. spec. complyin g to all conditions as mentioned as per clause 5.12.1 of rcf spec. no. mdts-219 ( rev.03) dt 04.03.2 020, corrigendum no. 1 [ warranty period: 84 months after the date of delivery ]
Tender For supply of fire retardant polycarbonate sheet of thickness - 3 mm, length -1220 mm and breadth - 915 mm conforming to ul 94 v0 of ls 14443 - 1997. [ warranty period: 30 months after the date of delivery ]
Tender For supply of fire retardant polycarbonate sheet of size 8 feet x 4 feet and of thickness 4 mm conforming to ul94 vo of is 14443-1997. [ warranty period: 30 months after the date of delivery ]
Tender For supply of fire retardant upholstery cloth width 157 +/- 2 cm for lhb ac chair car. spec. rcf spec . no. mdts - 44386 rev - nil dt. 20.02.2023 [ warranty period: 84 months after the date of delivery ]