Tender For as per nit and tender document - carrying out door to door survey for physical verification of properties and available services in jafrabad nagar panchayat.
Tender For engagement of consultant for checking and verification of stability of 4 (four) nos. existing foundation, submission of vetted structural drawing vetted design vetted structural analysis preparation of estimate submission of vetted estimate for const
Tender For e-bid for rate contract cum supply and empanelment of surgical items - "sterile disposable perfusion set (infusion set) with airway and needle (paediatric use) burette type measured volume chamber of 100 ml drop size of approx 60 drops per ml injection port,latexfree, for intermittent medication. floating auto shut off valve (latex free) in burette. soft and kink resistant pvc tubing. roller controller for flow control tube length 150 cm 23g needle as per iso 8536-5", "sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 20g should be packed in transparent, single blister pack. as per is 10555 standard", "sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 22g should be packed in transparent, single blister pack. as per is 10555 standard", "sterile disposable (single use) teflon/ ptfe i.v. cannula without port. size 24g suitable for paediatric & neonatal use should be packed in transparent, single blister pack. as per is 10555 standard", "plaster of paris bandages 15cm x 2.7mts / roll testing parameter should befollowed as per bp standard", urine collecting bag, disposable 2000 ml transparent sheet kink resistant flexible tubing not less than 90 cm in length should have non-return valve top drainage outlet graduated bag moulded handle for easy handling, vaccum suction set, 2.5 meter length, suction handle with suction tube sterile, pyrogenic free, latex free, single use, vascular catheter 5fr/16g, double lumen length 50cm.usfda/four digit notified ce approved. should have two guide wire 45 cm & 80cm or more(logline iv.) peel-away sheath glide thru 5fr *10 cm, guide wire nitinol 80 cm, guide wire nitinol 45 cm, introducer needle 21 g *7 cm,syringe-10 ml luer-lock, skin protectant prep pad, second site adjustable hub, measuring tape,5 fr pressure injectable picc line with blue flex tip 50 cm, dressing statloock stabilization device , vascular catheter 5fr/16g, double lumen length 55cm.usfda/ four digit notified ce approved, should have two guide wire 45cm & 80cm or more (logline iv.) peel-away sheath glide thru 5fr *10 cm,guide wire nitinol 80 cm,guide wire nitinol 45 cm,introducer needle 21 g*7 cm, syringe-10 ml luer-lock, skin protectant prep pad, second site adjustable hub, measuring tape,5 fr pressure injectable picc line with blue flex tip 55cm, dressing statloock stabilization device (suture less), vascular catheter with metal guide wire,5fr triple lumen, size range 55cm or more (logline iv:)usfda/four digit notified ce approvedsyringe 12 ml, internal stylet, measuring tape, stat lock catheter stabilization device (suture less), introducer safety peripheral iv catheter 20g,micro introducer with vessel dilator, guide wire-50 cm nitinol, needle introducer 21 g, safety scalpel,end cap, "core biopsy instrument with compatible co-axial needle (automatic disposal ) should be bevel tip.should have adjustable penetration depth of 18mm and 25 mm with automatic and semi- automatic firing modes in single instrument/gun.should have fire ready indicator to reduce the risk of premature instrument firing.should have advanced echogenic technology for enhanced visibility in ultrasound.should be available with compatible coaxial needle in a single kit. instrument / gun size: 18 gauge, 16cm with coaxial needle size: 17gauge, total cannula length 12.9cm.", disposable bone marrow biopsy needleshould have ergonomic two- piece t-handle design.should have trocar tapered stylet point for easy coring of bone.should have triple crown cannula tip with 6 cutting cannula facets.should be available with marrow acquisition cradle with sample size verification marking.11gauge, 4 inch length", "absorbable surgical suture (synthetic)antibacterial coated sterilised needled suture (braided coated polyglactin/ polyglycolic acid violet) 1/2 circle ct round bodied40mm, gs needle, suture length 90 cm", bed side leucodepletion filters for blood transfusion (for 2 u
Tender For conducting drone-based demographic survey and preparation of a detailed surface map, plot/ house hold wise physical status verification. composition with pjoc and pw underground working plan after preparation and updating, showing current surface status
Tender For repairing, testing, and reinstallation of annunciator power supply module installed on the annunciator panel of the ganvi power house stage 1. - repairing, testing, and reinstallation of. annunciator power supply module (220 v dc dc converter), installed on the annunciator panel of the ganvi power house stage 1, make: procon instrumentation. the scope of work shall include the following activities and components:1. detailed inspection, fault diagnosis, and functional assessment of the 220 v dc multi stage power supply module, including checking for voltage regulation, filtering stages, and isolation circuits to identify defective or burnt-out components.2. replacement of all damaged or deteriorated components such as capacitors, transistors, ics, connectors, or equivalent electronic parts with new or equivalent components of suitable ratings and manufacturer-approved quality.3. thorough testing and calibration of the repaired power supply module, verifying all intermediate and final stage voltage outputs, and load-bearing capability to ensure compliance with the original design parameters.4. execution of full-load performance and endurance testing at the power house after repair, ensuring stable operation and satisfactory performance of all annunciator functions under service conditions.5. reinstallation, wiring reconnection, and on-site commissioning of the repaired power supply module, including verification of proper signal integration with the annunciation system.6. the quoted rate shall include all necessary tools, testing instruments, labour, transportation, consumables, and incidental materials required for successful completion of the job to the satisfaction of the engineer-in-charge.
Tender For scr construction organization: appointment of technical consultant for providing architectural and technical consultancy for feasibility study, planning, designing, engineering & preparation of dpr for epc document consisting of scope, design basis criteria, specification for construction, gads, price schedule etc. and verification of drawings & technical data sheets (tds) of contractor during the construction period for indian railway tier-iii disaster recovery data centre along with allied buildings at moula-ali, secunderabad