Get complete information related to latest Cng Gas Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cng Gas Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cng Gas Tenders.
Tender For supply of r-290 refrigerant gas can/cylinder, chemical formula c3h8, weight 150 gm or more, make godrej or camipro or totaline or vijay for split air conditioner.
Tender For bid to ras supply of renovation of ground floor and mess of maharana pratap hostel of rttc campus in jaipur c c - supplying and fixing dp sheet steel enclosure , providing and testing ding dong type sound two module call bell , dismentalling of 1200 mm ceiling fan from hostel rooms , itc of above existing 1200mm ceiling fan , dismentalling servicing and complete repairing other than rewinding and itc of 300 mm exhaust fan , dismentalling serviceing and repairing including rewinding and itc of 300 mm exhaust fan , dismentalling servicing and complete repairing other than rewinding and itc of 450 mm exhaust fan , dismentalling serviceing and repairing including rewinding and itc of 450 mm exhaust fan , sitc ip20 18 20 watt led batten type integrated light fixture , supplying and fixing of vertical type 15 litre capacity 2000 watt water storage electric geyser , sitc ip20 10 watt led batten type integrated light fixture , installation of upto 2 tr capacity split ac units , pdg and fixing 1 by 4 inch dia copper refrigerant piping , pdg and fixing 5 by 8 inch dia copper refrigerant piping , provision of top up or additional charging of r-22 or 32 gas , s f suitable size ms stand for placement of split type ac outdoor unit , providing and fixing 20 mm dia heavy duty pvc pipe , sand fsuitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb , supplying and fixing of 3 x 2. 5 sq mm pvc insulated and frls , repairing and painting of existing 3 mtr height galvanised mild steel pole , repairing and painting of existing 7 mtr height galvanised mild steel pole , supply installation testing commissioning of led post top type 30 watt with ip 65 , sitc of 18 watt energy efficient led type 12 inch size polycarbonate globe fittings , sitc of 50 watt energy efficient led flood light luminaire with inbuilt high power leds , supplying and laying of 63 mm dia od 63 mm and id 51 mm nominal size dwc hdpe pipe , laying and fixing of one number pvc xlpe insulated and pvc sheathed xlpe power cable of 1. 1 kv grade of upto 35 sq. mm on surface , laying and fixing of one number pvc xlpe insulated and pvc sheathed xlpe power cable of 1. 1 kv grade of upto 35 sq. mm in pipe , laying and fixing of one number pvc xlpe insulated and pvc sheathed xlpe power cable of 1. 1 kv grade of upto 35 sq. mm in ground , laying and fixing of one number pvc xlpe insulated and pvc sheathed xlpe power cable of 1. 1 kv grade of upto 35 sq. mm in ground additional , supplying and making end termination with brass compression gland and aluminium lugs for 2 x 6 sq mm 22mm size , supply of 1 no xlpe insulated and pvc sheathed power cable of 1 point 1 kv grade of size 2 x 6 sqmm aluminium conductor armoured cable , providing and fixing 6 swg dia gi wire on surface or in recess for loop earthing , supplying and fixing digital weekly programmable time switch astronomical weekly programmable alongwith 10 amp 3 pole power contractor , providing laying and fixing 50 mm dia gi pipe medium class in ground complete with gi fittings including finishing etc as required , providing laying and fixing 32 mm dia gi pipe medium class in ground complete with gi fittings including finishing etc as required , supply and fixing 40 mm dia b class gi pipe 500 mm length with 150 mm x 150 mm x 3mm thick ms base plate , repairing of dust and vermin proof cubical out door double door type floor mounted , sitc of self contained drinking water cooler with non cfc refrigerant energy efficient compressor
Tender For corrigendum : supply of supply of refrigerant r22 gas along with cylinder suitable for filling / top up for 2 ton or 1. 5 to , supply of refrigerant r32 gas along with cylinder suitable for filling / top up for 2 ton or 1. 5 ton , supply of refrigerant r410a gas along with cylinder suitable for filling / top up for 4 ton tower ac , supply of refrigerant r134 gas along with cylinder for filling or top up for industrial water cooler
Tender For supply of demand of stores d d--pvc copper cable single core and multi core circular sheathed cable with rigid conductor (v2) as per is 694 (q2) , outdoor unit for split ac 1 point 5 ton without compressor , complete outdoor unit for split ac 1 point 5 ton without compressor , suction or liquid line valve of size 1by 4 dia , suction or liquid line valve of size 3by 8 dia , insulation of size 1 by 4 dia for copper pipe , insulation of size 3 by 8 dia for copper pipe , indoor unit for split ac 1 point 5 ton , without compressor outer complete unit for window ac 1 point 5 ton , bracket for holding outdoor unit , pencil cell for ac remote , rotary type sealed compressor of cap 1 point 5 tr , indoor unit pcb suitable for all weather type 1 point 5 ton inverter ac , reciprocating type sealed compressor of cap 1 point 5 tr , reciprocating type sealed compressor of cap 2 tr , front grill for window type ac 2 tr , teflon tape , capacitor 50 add 6 mfd , capacitor 80 by 100 mfd , indoor blower motor for split ac 1 point 5 ton , crca sheet steel plug and socket distribution board 20 amp , exhaust motor for split ac 1 point 5 ton , outdoor unit pcb suitable for all weather type 1 point 5 ton inverter ac , flexible pvc drain pipe for ac , refrigerant gas r 22 , copper pipe of size 1 by 2 dia , copper pipe of size 1 by 4 dia , refrigerant gas r 134a , exhaust motor for split ac 1 point 8 or 2 ton , outdoor unit pcb suitable for all weather type 1 point 8 or 2 ton inverter ac , axial fan 14 x 4 inches for water cooler , starting relay 1 by 22 , starting relay 1 by 24 , suction or liquid line valve of size 5 by 8 dia , rotary type sealed compressor of cap 2 tr , capacitor 36 mfd , indoor unit pcb suitable for all weather type 1 point 8 or 2 ton inverter ac , insulation of size 1 by 2 dia for copper pipe , insulation of size 5 by 8 dia for copper pipe , indoor unit for split ac 2 ton , without compressor outer complete unit for window ac 2 ton , copper pipe of size 3 by 8 dia , copper pipe of size 5 by 8 dia , ac cleaning spray foam type 500 ml , a c descaling agent for split ac cap 1 point 5 or 2 tr , tpn db 4 way , vtpn db 4 way , spn db 8 way , spn db 12 way , electric exhaust fan 300 mm , electric ceiling fan with bldc motor 1200 mm , indoor blower motor for split ac 2 ton , automatic fire suppression system for electric panel 4 kg , automatic fire suppression system for electric panel 2 kg , automatic fire suppression system for electric panel 1 kg //bid details2 / 44
Tender For procurement of refrigerant gas r-22 for package a.c system installed in dm plant, esp-10 and 11, hcsd, ahp, switchyard buildings of ph-iv and ph-iii ac system and refrigerant gas r-407 for instrument drier of ahp plant of ph-iv, stps sarni.
Tender For tender for supply of supply of vrf ivrf inverter type air conditioning system , indoor units with all supporting materials for hanging and fixing for existing duct. a 6tr ducted indoor , b 8tr ducted indoor , c corded remotes , d cordless remotes , installation nitrogen pressure testing vaccumising and commissioning of vrf ivrf inverter type odu units , installation charges for ducted indoor units , supply and laying of hard drawn copper refrigerant piping with elbows couplings reducer and slotted supports for suction and discharge line , supply and fixing of 19mm and 13mm thick nitrile rubber insulation for above copper pipe and ppe covering with fire retardant tape , refrigerant gas charging r410a , lifting shifting and erection of ivrf outdoor units , communication cable for idu to odu , drain pipe cpvc with insulation , ms channel stand for odu units , dismantling charges for existing indoor units , dismantling charges for existing outdoor units , canvas fire proof for connection between indoor and cool air duct connection