Web Analytics Made Easy - StatCounter

Coagulation Analyser Tenders

Get complete information related to latest Coagulation Analyser Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Coagulation Analyser Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Coagulation Analyser Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40985783 Due date: 28 Jul, 202528 Jul, 2025 1.50 Crore
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a

Co-operative

CTN :40555356 Due date: 14 Jul, 202514 Jul, 2025 35.0 Thousand
Tender For corrigendum : osp job for repairing of o2 online oxygen gas analyzer

CTN :40914621 Due date: 04 Jun, 202504 Jun, 2025 NA
Tender For tender for the procurement, rate contract and supply of medical equipment for different govt. health institutions of bihar.-, haematology analyser(3 part), fully automated biochemistry analyser, semi-automated bio-chemistry analyser, automated coagulation analyser (semi), electrolyte analyzer, flurometry, chemiluminescence immunoassay, turbidometer,

State Government

CTN :40890110 Due date: 07 Jul, 202507 Jul, 2025 7.40 Lacs
Tender For automated urine chemistry analyser &ampamp four channel semi automated coagulation analyser &ampamp esr analyser

CTN :40767340 Due date: 04 Jul, 202504 Jul, 2025 NA
Tender For supply, installation and commissioning of gas analyzer with co2 and o2 probe for the rgm funded project "implementation of ivf technology under rgm at cvsc, aau, khanapara & establishment of professional training institute at lcvsc, aau, lakhimpur

Central Government/Public Sector

CTN :40843677 Due date: 16 Jul, 202516 Jul, 2025 NA
Tender For supply, installation and commissioning of portable flue gas analyzer for thedetermination of oxygen (o2), carbon dioxide (co2), carbon monoxide (co andco low), nitric oxide (no & no low), nitrogen dioxide (no2), hydrogen sulphide(h2s), hydrocarbon(hc), sulphur dioxide (so2), temperature, efficiencyand pressure in flue gas stack outlet and other gas samples. technicalspecifications strictely as per attached annexure 1 and 2

Central Government / Public Sector

CTN :40827169 Due date: 04 Jul, 202504 Jul, 2025 NA
Tender For providing of custom bid for services - single tender 9030c25b73 annual maintenance contract of antek make sulphur analyzer and icon make flash point analyzer installed in dhds and ametek make o2 analyzers installed in dhdt ii unit of gujarat refinery

CTN :40811464 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For supply of elemental analyzer d d - silver wool 50 gm product code 200005872 , wo3 granulate for filling comb tube product code 200008986 , quartz wool 10 g product code 200004827 , copper 100 g product code 200014271 , corundum balls 50 g product code 200010245 , protective tube 105 mm slotted product code 200014026 , tin capsules v 0.05 ml 250 pc product code 200015479 , ash finger 60 mm slotted product code 200014555 , combustion or reduction tube quartz product code 200007844 , tin boats thin 4x4x11 mm 1000 pc product code 200014577 , o2 lance 150 mm product code 200004159 , aluminium oxide wool 20 g product code 200004773 , oxygen lance sealing 10 pc product code 200010515 , vmiccu visosel maint product code 200007336 , support tube 65 mm product code 200011820 , 2 by 2 magnetic valve product code 200004891 , 3 by 2 magnetic valve 24 vdc product code 200011239 , acetanilide 5 g product code 200007435

CTN :40693314 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For call for objection against procurement of consumables for ceveron coagulation analyser - pt reagent, aptt reagents+cacl2, calcium chloride 25mmol/lt, thrombin time, fibrinogen reagents, d-dimmer latex kit, d-dimmer control high, d-dimmer control low, calibration plasma, coagulation control normal, coagulation control abnormal, factor ii immunodepleted, factor v immunodepleted, factor vii immunodepleted, factor viii native, factor viii immunodepleted, factor ix native, factor ix immunodepleted, factor x native, factor xi native, factor xii native, imidazole buffer, technochrom at iii kit, protein c, protein s, lupus anticoagulant screen, lupus anticoagulant confirm, cuvettes (50x12) for ceveron, system solution, cleaning solution, wash solution, magnetic stirrer, technochrom anti-xa, technoview lmw heparin calibrator set, technoview lmw heparin low control, technoview lmw heparin medium control, technoview lmw heparin high control
 Loading, Please wait...

Connect us via What's Up