Get complete information related to latest Coal Pulveriser Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Coal Pulveriser Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Coal Pulveriser Tenders.
Tender For static equipment maintenance works at ammonia complex during ata 2025, as per tender conditions. - tube bundle pulling - e 213 a, insitu machining of the gasket face of the shell flange of e213 a, tube bundle pulling - e 1001, vessel inspection - f551, f552 and f553, de bolting the air sparger (mixer) and pipings including nrv of secondary reformer, bringing down and keep on stand for facilitating inspection and repair, fix back the sparger (mixer) after repair and fixing back the piping and fittings including nrv after replacing the gaskets., flare tip cleaning - cleaning of pilot burner tips (6 nos) of flare stack of size : 25 nb, skilled mechanical jobs including machinery / equipment installation, dismantling & refixing of pressure joints, piping & pipeline works, welding, machining jobsetc. requiring skilled workers. rate shall be quoted for man days of 8 hrs.
Tender For supply of laboratory and scientific equipment/tools - laboratory and scientific instruments/tools, compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r22, cooling capacity: 2355 kcal/hr type, voltage 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r134a, cooling capacity: 1411kcal/hr, voltage: 440vac, 25mfd, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type:r134a, cooling capacity: 0.25hp; supply voltage: 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., capillary tube : 1.12 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.20 mm od, 8 ft, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.40 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 0.95 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., thermostatic expansion valve: orifice- 0 no., connection-1/2 x 3/8 flare (details as per sl. no. 3 at annexure-i)., thermostatic expansion valve: ten 068z3348, q-33311 r134a -40 to 10 ps 34 bar. (details as per sl. no. 3 at annexure-i)., hand stop /manual shut-off valve: media: r22, r502, r134a, r407c, r410a; port size: 3/8" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., hand stop /manual shut-off valve: media: media: r22, r502, r134a, r407c, r410a; port size: 1/4" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., evaporator coil : 1/4" od, material: copper astm b280 (details as per sl. no. 5 at annexure-i)., condenser coil ; 3/8" od, material: copper astm b280 (details as per sl. no. 6 at annexure-i)., dimmer stat : 1500 w, 230 v ac. single phase, 50hz (details as per sl. no. 7 at annexure-i)., pressure gauge : connection 1/ npt 8 0 - 200 psi dial size 2.5" (63mm), connection sizes 1/4" (details as per sl. no. 8 at annexure-i)., digital temperature indicator : range -30 to 200 0c, power supply 230vac, digital display, accuracy 0.01 c channel -12 (details as per sl. no. 9 at annexure-i)., digital temperature indicator : type input cr-al(k-type), rang- 0 0c to 200 0c supply- 230vac, 50hz, channel -12 (details as per sl. no. 9 at annexure-i)., ammeter (digital) : rang 0-10 amp. single phase, digital display, 230v,10%vac (details as per sl. no. 10 at annexure-i)., voltmeter (digital) : rang 0 300-volt, single phase, digital display (details as per sl. no. 11 at annexure-i)., hp/lp cut out relay : hp- 8 to 32 bar, lp-0.2 to 7.5 bar, dual controls, 240 v, 50 va, single pole changeover switch (spdt), contact load 240 v ac: 8 fla, 48 lra (details as per sl. no. 12 at annexure-i)., energy meter : a.c. single phase, 2 wire solid state (static) fully electronic energy meter, accuracy class 1.0 & current rating 5-30 amp. with backlit lcd display for240 volt system fitted with pilfer proof meter box.(details as per sl. no. 13 at annexure-i)., r-134a refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; application: refrigerant; type of refrigerant-r134a. (details as per sl. no. 14 at annexure-i)., r-141b refrigerant gas : 5 kg filled cylinder; purity 99.9% appearance: colourless (details as per sl. no. 15 at annexure-a)., r502 refrigerant gas : 5 kg filled cylinder; acidity 0.00001 % appearance: colourless purity 99.9 % (details as per sl. no. 16 at annexure-i)., r407c refrigerant gas : 5 kg filled cylinder; appearance: colourless purity 99.9 % (details as per sl. no. 17 at annexure-i)., r-1234ze hfo refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; (det