Get complete information related to latest Collecting Tank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Collecting Tank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Collecting Tank Tenders.
Tender For corrigendum : operation and maintenance of 86 mld mps and 30 mld stp at hsp 2024-25 charges for desilting of 02 no. of collectingtanks of mps and other works at hsp.
Tender For resilient and sustainable service delivery in water supply scheme in jsv sub division bhaderwar division sarkaghat distt. mandi hp (under jjm) (sh:-connectivity of buffer storage tank) job no.2
Tender For resilient and sustainable service delivery in water supply scheme in jsv sub division bhaderwar division sarkaghat distt. mandi hp (under jjm) (sh:-connectivity of buffer storage tank of lwss baggi khuddi khahan)
Tender For resilient and sustainable service delivery in water supply scheme in jsv sub division bhaderwar division sarkaghat distt. mandi hp (under jjm) (sh:-connectivity of buffer storage tank of lwss baggi khuddi khahan)
Tender For special repair of internal roads with provision of wbm plus 30mm bc and service road with provision of gsb plus ipb, repair of boundary wall, providing storm water line with pump chamber and collectingtank and construction of 02 nos. main gates
Tender For supplying, installation, testing and commissioning of equipment for setting up of water testing laboratory at je(water supply section) sd-i, apwd, diglipur. chemical parameters testing - supply, installation, testing and commissioning of bench top multiparameter ph meter edge - model - hi2020 of make hanna or equivalent with required buffer/stock solution complete having following specification:, ph electrode : hi11310 ph electrode connectivity : 1 micro usb port for charging and pc connectivity, 1 usb port for storagebattery type/life : built-in rechargeable battery with up to 8 hours of continuous usepower supply : 230vac to 5 vdc adapter environment : 0 to 50 c (32 to 122 f), rh max 95% non-condensingdimensions : 202 x 140 x 12.7mm (8 x 5.5 x 0.5 )weight : 250 g (8.82 oz)( the supplier is also required to supply 01 no. additional hi11310 ph eclectrode of same make and specification & additional 500 ml bottle of standard calibration solution of ph 4.01, 7.01 and 10.01 each , 500 ml bottle of electrode storage solution and 500 ml bottle of general pourpose cleaning solution of make hanna along with the above specified instrument set), supply, installation, testing and commissioning of bench top multiparameter ec/tds/salinity meter edge - model - hi2030 of make hanna or equivalent with required buffer/stock solution complete having following specification:, ec/tds probe : hi 763100 ec/temperature probeconnectivity : 1 micro usb port for charging and pc connectivity, 1 usb port for storageglp : yesbattery type/life : built-in rechargeable battery with up to 8 hours of continuous usepower supply : 230vac to 5 vdc adapter environment : 0 to 50 c (32 to 122 f), rh max 95% non-condensingdimensions : 202 x 140 x 12.7mm (8 x 5.5 x 0.5 )weight : 250 g (8.82 oz)( the supplier is also required to supply 01 no. additional hi763100 ec/temperature probe of same make and specification & additional 500 ml bottle of standard conductivity solution of 1413 s/cm , 5000 s/cm and 12880 s/cm each of make hanna along with the above specified instrument set), supply, installation, testing and commissioning of epa compliant benchtop turbidity and chlorine meter - model - hi83414 of make hanna or equivalent with required calibration cuvettes complete having following specification:, turbidity range : non-ratio mode: 0.00 to 9.99; 10.0 to 40.0 ntu; 0.0 to 99.9; 100 to 268 nephelos; 0.00 to 9.80 ebc turbidity range : ratio mode: 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 ntu; 0.0 to 99.9; 100 to 26800 nephelos; 0.00 to 9.99; 10.0 to 99.9; 100 to 980 ebc.free chlorine range : 0.00 to 5.00 mg/ltotal chlorine range : 0.00 to 5.00 mg/lconnectivity : usbglp : last calibration data, calibration infoauto end : do onlybod/our/sour : yes (inside/outside limits)display : 40 x 70 mm graphic lcd (64 x 128 pixels) with backlightpower supply : 115/130 vac; 50/60 hzenvironment : 0 to 50 c (32 to 122 f), rh max 95% non-condensingdimensions : 230 x 200 x 145 mm (9.0 x 7.9 x 5.7 )weight : 2.5 kg (88 oz.)( the supplier is also required to supply 04 nos. additional calibration glass cuvettes for turbidity and chlorine, 230 ml cuvettes cleaning solution, silicone oil each of make hanna along with the above specified instrument set), supply, installation, testing and commissioning of water & wastewater multiparameter (with cod) photometer and ph meter - model - hi83399 of make hanna or equivalent with required calibration cuvettes complete having following specification:, input channels : 1 ph electrode input and 5 photometer wavelengthsphotometer/colorimeter light source : 5 leds with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filtersphotometer/colorimeter light detector : silicon photo detectornumber of methods : 128 max.connectivity : usb-a host for flash drive; micro-usb-b for power and computer connectivityglp : calibration data for connected ph electrodedisplay :128 x 64 pixel lcd with backlightpower supply : 5 vdc usb 2.0 power adapter