Tender For supply of high carbon galvanized steel wire rope o [high carbon galvanized steel wire rope of size 20 mm(6x36) fiber core round stands right hand ordinary lay tensile strength 1960n/mm2 confirming to is 2266/2002 for eot crane with material testing certificate and load testing certificate and proof of purchase from oem or authorized dealer only.make: - usha martin/bombay wire rope/desh wire rope/bharat wire rope or equivalent.]
Tender For corrigendum : all work related to installation of double pole meter on the premises of consumers of 10 kw and above load in electrical testing area-i in the jurisdiction of electrical urban testing section-i, ghaziabad.
Tender For repair of vaccum circuit breaker - taking out vacuum interruptor bottle , supply and fixing vacuum interruptor bottel suitable for ht vcb , testing of vcb on load after installation of vcb complete all as specified and directed , taking out battery power pack from vcb at domestic area complete all as specified and directed , material and labour for battery power pack for 11 kv vcb i p 230v ac o p 24vdc complete all as specified and directed
Tender For providing of custom bid for services - routine electrical maintenance of termin,custom bid for services - maintenance of earth pit,custom bid for services - transformer oil filtration,custom bid for services - transformer oil testing,custom bid for services - testing of relay,custom bid for services - servicing of circuit breaker,custom bid for services - servicing of vcb breaker,custom bid for services - thermography test report,custom bid for services - light replacement at height,custom bid for services - manpower assistance in emergen,custom bid for services - laying of powercontrol cables,custom bid for services - sup of green wire 6sqmm,custom bid for services - laying of cable tray and cover,custom bid for services - load testing of battery banks,custom bid for services - supply electrical rubber mat 3mm,custom bid for services - supply electrical rubber mat 2 point 5mm,custom bid for services - sply of electrical tape
Tender For quotation enquiry for the work of new electrification works in building materials testing lab civil engg department at vnit campus nagpur - new electrification works in building materials & testing lab, civil engg. department at v.n.i.t. campus, nagpur., providing & erecting 4 pole mccb, 415v, up to 100a, rated short-circuit breaking capacity 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/uv/trip alarm contact. mccb with phase barriers on both sides, insulation withstand capacity 800v, no line-load bias in provided enclosure/panel as per specification no. sw-mccb, supplying and erecting ss enclosure of 1.6mm thick with detachable gland plate suitable for upto 100a mccb., supplying, erecting, testing & commisioning bus bar chamber triple pole with neutral with four copper bars, 500v, 100a having 10mm ( width) x 1.6 mm (thickness), with 99.9 % copper purity as per e91e grade & current density 1.6 a per sq mm compliance to is 5082 and enclosure fabricated with 16 swg crca sheet and epoxy paint, with suitable number of ways and with smc/dmc insulators and accessories of suitable rating and two nos of separate earthing terminals complete as per specification no. cp-bb, supplying, erecting, testing & commisioning bus bar chamber triple pole with neutral with four copper bars, 500v 200a having 20mm ( width) x 2 mm (thickness), with 99.9 % copper purity as per e91e grade & current density 1.6 a per sq mm compliance to is 5082 and enclosure fabricated with 16 swg crca sheet and epoxy paint, with suitable number of ways and with smc/dmc insulators and accessories of suitable rating complete as per specification no. cpbb, supplying, erecting & terminating fr xlpe insulated, galvanised steel formed wire armoured (strip) cable, 1100 v 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. cb-lt/al, supplying, erecting & marking fp mcb 63a, with rated short - circuit breaking capacity (icn) 10ka in provided distribution board as per specification no. sw-mcb, supplying & erecting crca sheet metal one way enclosures of 1.2mm thickness suitable for dp mcb/tp mcb/fp mcb/rccb/rcbo complete erected on provided angle iron/gi frame., supplying & erecting mains with 4x16 sq.mm frlsh copper pvc insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. wg-ma/bw, supplying and erecting exhaust fan heavy duty 230 v a.c. 50 cycles 375/380 mm. 1400 rpm complete erected in position as per specification no. fgfn/exf, supplying & erecting of 20w led tubelight combined fitting with 01 year warranty, point wiring for light/bell/exhaust fan in pvc trunking (casing-capping) with 1.5 sq.mm (2+1e) frlsh grade copper wire, modular type switch, earthing and required accessories as per specification no. wg-pw/sw, supplying and erecting modular type switch 16a on provided plate and box with wiring connections complete., supplying and erecting modular type 3 pin 6/16a multi socket with safety shutter on provided plate and box with wiring connections complete., supplying and erecting 16a, 10ka, spmcb suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected., supplying and erecting modular type blanking plate one module, on provided plate & box., supplying and erecting pvc surface modular switch box with double mounting & front plate for 8 module complete duly connected., supplying and erecting pvc trunking (pvc casing-n-capping) of size 25mm with accessories on wall/ceiling as per specification no. wg-ma/con., supplying and erecting pvc trunking (pvc casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification no. wg-ma/con., supplying pedestal type air circulator 600
Tender For supply of material and labour for disconnecting the cabel connection from conventional starter complete all as specified and directed , material and labour for taking down conventional starter and removing to mes store for issue as sch of credit complete all as spd and directed. , supply and fixing variable frequecy drive vfd 15 hp 3 phase heavy duty 380 to 480 volt strong overload capacity with enclosure panel complete all as specified and directed , material and labour for reconnecting the cabel connection of vfd and mccb complete all as specified and directed , material and labour for testing of vfd on load with complete satisfaction of engineer in charge complete all as specified and directed
Tender For supplying and installation of machines / instruments in tile section at technical laboratory, mcd, alipur road, civil lines, delhi-110054. - mor apparatus (capable for 600mmx600mm dimension of tiles) as per is: 13630:p6:2019, and 2nd rev.machine/instrument details :- two cylindrical support rods it shall be made of metal and the parts in contact with the test specimen shall be covered with rubber having a hardness of 50 5 irhd, measured in accordance with is 3400 (part 2). one rod shall be slightly pivotable and the other shall be slightly rotatable about its own axis. central cylindrical rod it shall be of the same diameter as the support rods and covered with similar rubber, which transmits the load. this rod shall also be slightly pivotable.diameter of the road : 20 1mmthickness of rubber : 5 1mmoverlapping of tile beyond the edge supports 10 1mm(a) with touch screen control panel and automatic pace rates control to obtain a rate of increase of stress of 1 0.2 n/mm square/ second, capacity 500 kgf, least count 0.1 kgf with adjustable test span to accommodate different sizes of tiles specimen up to 600mmx600mm dimension & thickness of up to 12mm., scratch hardness test kit according to mohs scale as per is 13630:p-13:2019, 2nd rev, calibrated thermal expansion apparatus as per is 13630: p-4:2019, 2nd rev.machine/instrument details:- the apparatus should be capable of heating at the rate of (5 1) oc/min with uniform distribution of heat to 20 nos. of test specimen of 600mmx600mm dimensions:(a) certain types of apparatus require a soaking time at 100 oc.(b) desiccator for 20 nos. of test specimen., determination of resistance to thermal shocklow temperature bath (capable for 600mmx600mm dimension of tiles) as per is 13630: p-5:2019, 2nd rev.machine / instrument details: - the apparatus should be capable of cold water flow at 15 5 oc :(a) testing with immersion:- bath for immersion test should not be covered and is of sufficient depth to allow the tiles to be placed vertically and immersed completely.(b) testing without immersion the bath for without immersion test should be covered with a 5 mm thick aluminum plate in such manner that the water directed towards the surface is in contact with the plate. covering the aluminum plate with a layer of aluminum grains approximately 5 mm thick with diameters in the range of 0.3 mm to 0.6 mm.(c) oven inside dimension of 900mm x 650mm x 650 mm (h x w x b) capable of reaching 145 oc -150 oc in 20 minutes (as per is 13630:p-5:2019, 2nd rev)., water bath capable for holding of 20 specimens of tiles of size 600mm x 600mm ,which are fully dipped in vertical position.