Get complete information related to latest Communication Cable Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Communication Cable Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Communication Cable Laying Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45036257 Due date: 07 May, 202607 May, 2026 35.53 Lacs
Tender For corrigendum : - modernization/upgradation of existing parks/green belts. sub head : supply and laying of power cable at baansera. estimated cost :- rs.35,53,304/-

corporations/Associations/Others

CTN :45084509 Due date: 26 May, 202626 May, 2026 38.43 Lacs
Tender For supply of round the clock maint of bchp wt to conv 8 , round the clock maint of bchp main route , round the clock elect. maint of a chp , shifting of 5 ton weights to wb , laying power cable up to 70 mm2 , laying power cable up to 70 to 400 mm2 , dismantling power cable up to 70mm2 , dismantling power cable upto 70 to 400mm2 , laying of different size of power cable , dismantling of difft of control cable , digging of existing cable trench , degging trench for relaying new cable , straight through jointing of lt cable , end termination of power cable , straight through jointing of ht cable , bend termination of power cable head , patrolling of ht cable upto 70mm2 , patrolling of lt cable up to 70mm2 , patrolling of ht cable upto 70 to 400mm2 , patrolling of control cable up 4mm2 , repairing fabrication of lighting panel , rewinding of ceiling fan , replacement of bearing of celing fan , provide bearing in place of bush , replacement of condenser of celing fan , replacement of shaft of ceiling fan. , complete oh of celing fan , cable trench of fuel handling area. , cable trench jt no.1 and crusher house , cable trench jt no.1 and jt no.2. , chp transformer trench to ahd unit 12 , cable trench from crusher house to wts , cleaning of mcc panel wt,sr fhd etc , cleaning of sm,md,coolin g pump,wb area , cleaning of control power panel fhd , cleaning of ldb in fuel oil in btps. , cleaning of control room,wb area a chp , cable rack and trays of fuel oil pump house , cable rack trays riser of crusher house. , cable rack trays riser of tower no.1 , cable rack between j.t. no.1 and conv. 16 , cable racks from jt no 1 and conv. 17. , cable rack trays of old stacker. , cable rack trays of new stacker. , cable rack trays from j.t. no.1 and j.t. 2 , cable rack trays of riser of j.t. no.2 , cable rack minus 4m gallery chp room , cable rack berween t.t. no.2 and t.t.no.3 , cable rack trays riser of tippler area. , cable rack trays riser of wagon tippler. , cable rack trays of conv. k10 , cable rack trays of conv. k16. , cleaning of floor gallery minus 4m chp , ceaning of panel in fuel oil , cleaning of sg room, trench a chp , cleaning of a chp cable trench sg area , cable trenches from c.h. to wts chp , cable trenches from jt no.1 to c.h. , cable trenches from jt no.1 to jt 2 , cable trenches from wt a chp to id fan , cable trays from wt a chp to id fan , o.h. and maint. of 5 and 10t hoists bchp , o.h. and maint. of 20 and 5t hoists and eot achp

CTN :45085020 Due date: 26 May, 202626 May, 2026 NA
Tender For supply of ptz camera with 64 gb sd card , bullet cameras with 64 gb sd card , 32 channel network video recorder , 16 channel network video recorder , supply and laying of 6 core armoured optical fibre cable , supply and installation of 12 port liu fully loaded with couplers and pigtails , industrial grade poe switch 8 -port, outdoor , 24 port 10 or 100 or 1000 mbps with 2 x 10g sfp ports layer 2 or 3 managed stackable switch , 55 inches full hd led display , workstation , workstation with wireless ceiling mounted indoor access point , supply of 9u wall rack , 6 core compact liu fully loaded with pigtails and couplers , 2.5 sq mm 3 core armoured power cable , 25 mm casing and capping as required , hdpe pipe for underground cabling , 25 mm pvc conduit pipe , air conditioning for control room , cat 6 stp cable 04 pair , ups system 1 kva , ups system 3 kva , 5 mtr camera pole with foundation and earthing , fibre patch cord - 1 mtr , 32 mm galvanised pipe - gi , 19u floor mount rack , supply of 9u outdoor junction box , installation testing and commissioning

Central Government And Public Sector

CTN :44982263 Due date: 11 May, 202611 May, 2026 2.15 Lacs
Tender For corrigendum : supply of sf 11 kv ms dp structure 11kv 200a 3 ph supply as specified , sf 11 kv 200 amp gaob switch as specified , sf 11 kv 200 amp heavy duty dropout fuse set as specified , replacment of ligting arrestor 9 kv, 5 ka as specified , replacement of polymer disc insulator 11 kv as specified , replacement of polymer pin insulator 11 kv as specified , earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick as specified , pvd fixing 25mm x 25mm gi strip in 40 mm dia gi pipe , pvd fixing 25mm x 25mm gi strip on surface or recess , supply laying 3 core 95 sq mm xlpe ht power cable 11kv in rcc hume pipe as specified , supply making indoor cable end termination with heat shrinkable jointing kit for 95 sq mm cable , supply making straight through cable jointing with heat shrinkable jointing kit for 95 sq mm cable , re fixing of existing protection cover arrangeement with wire mesh ms angle structure etc , providing gi or ms wire mesh i.e. netting of weleded or woven gi or ms wires , supply fixing ms structure of suitable size

CTN :45076130 Due date: 05 May, 202605 May, 2026 NA
Tender For supply, installation, testing and commissioning of electrical panels and supply & laying of cable for augmentation of power supply to provide ac load for biochemical engineering, pharmaceutical engineering, chemical engineering,.................................... and supply, installation, testing and commissioning of passenger lift with rcc lift pit etc. at iit (bhu), varanasi. (sh supply, installation, testing and commissioning of electrical panel and supplying and laying of cable) (sh indoor plantation work at cpwd electrical office)

CTN :45067313 Due date: 25 May, 202625 May, 2026 NA
Tender For supply of biomatric face recognise system with turnstile flap barrier - turnstile tripod , flap barrier , glass work , facial recognition biomatric , handheld biomatric machine , rfid card , i7 workstation , cat 6 stp armoured cable , power cable 3 core , poe switch , fiber module , 6u indoor networking rack , inverter cum ups 1 kva , ofc 6 core armoured cable , installation operation software labour, af personnel and vms , laying of ofc cable , installation testing and commissioning

CTN :45021978 Due date: 02 May, 202602 May, 2026 37.99 Lacs
Tender For corrigendum : additional cable laying work for new upgraded lt panel at main building honble supreme court of indiasubwork/packages:provision of vc panel for restoration of power supply in transformer no. 4

CTN :45057459 Due date: 22 May, 202622 May, 2026 NA
Tender For tender for supply, installation testing and commissioning of it & electrical components for vams - supply and installation of 12u rack, supply and installation of 12 port managed n/w switch, supply and installation of 8 port managed n/w switch, 4+2 poe switch for power up the ip camera, supply and installation of gigabyte media convertor, supply and installation of patch cards, supply and installation of power jb, supply and installation of control jb, supply and installation of long-range wifi router, supply and installation of 6c sc ofc cable, supply and laying of 3c*2.5 sqmm armoured cable, supply and laying of cat-6 cable, supply and installation of 42 u rack, supply and installation of 24 port managed switch, supply and installation of pdp pannel, supply and installation of p10 display unit with 2 feet, * 6inch for driver information purpose, supply and installation of 10kva ups 3phase in, 1phase out with redundant setup, supply and installation of smf battery 42ah, supply and installation of battery stand and interlinks, flp gland, non flp gland

CTN :44914160 Due date: 05 May, 202605 May, 2026 NA
Tender For bid to ras supply of diesel power generator (up to 900 kva) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) , s & f earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick , supply & fixing or laying hdpe dwc pipe of 120 mm dia (outer dia-120 mm & inner dia-103 mm nominal)

Central Government/Public Sector

CTN :42424475 Due date: 04 May, 202604 May, 2026 NA
Tender For bid to ras supply of flexible copper trailing cables d d - item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall dia