Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs rajdhwaj; l-02,l30,l-267,e-14; service provider-01 l-02 the following test equipment available onboard are to calibrated through nabl accredited lab and calibration certificates for the same to be provided:- (a) analog multimeter qty:01) (b) digital multimeter (qty:02) (c) digital tong tester(qty:01) (d) megger (qty :01) no. 01, l-030 04 nos ceremonial sockets at flag deck is deteriorated. same to be repaired/replaced as per sample. no. 01, l-267 open panels of ecdis and check all terminal block connection and tighten if becoming loose. check brilliancy knob, system setting and various feed data nmea voltages coming from various navigation equipment. no. 01, e-014 different equipment gauge lines observe deteriorated/corroded view fair wear and tear(mat : cu-ni) gauge line to be brazed/renewed as per sample and prove. no. 01.
Tender For providing of custom bid for services - provisioning of ncn connectivity to new building (calibration and instrumentation block) and other offices of dgnp(v)
Tender For supply of iiw calibration block type- vi as per is 4904:2006 with csir-national physical labor atory, new delhi certification. make / brand- modsonic / eec or similar. item to be supplied along with cali bration certificate. firm's offer: make/brand: modsonic instruments mfg. co. pvt. ltd., ahmedabad ., iiw calibration test block type v1 with npl certification (validity of npl certificate is 24 months from the date of issue) [ warranty period: 30 months after the date of delivery ]
Tender For providing of operation and maintenance of electrical systems/electrical installations - service item no 1- manpower,operation and maintenance of electrical systems/electrical installations - service item no 2- serial lighting to terminal building & atc block,operation and maintenance of electrical systems/electrical installations - service item no 3 - testing and calibration of protective relays,operation and maintenance of electrical systems/electrical installations - service item no 4 - servicing of lt air circuit breaker,operation and maintenance of electrical systems/electrical installations - service item no 5 - servicing of ht vaccume circuit breaker,operation and maintenance of electrical systems/electrical installations - service item no 6- painting of transformer housing box,operation and maintenance of electrical systems/electrical installations - service item no 7 - rewinding of the 7 to 10 hp submersible motor pump sets,operation and maintenance of electrical systems/electrical installations - service item no
Tender For empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint. # th
Tender For supply , installation and commissioning of eddy current array equipments for testing of lhb wheel disc along with necessary probe, accessories and calibration block, make- sg-ndt/similar [ warrant y period: 30 months after the date of delivery ]