Web Analytics Made Easy - StatCounter

Computer Ups Tenders

Get complete information related to latest Computer Ups Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Computer Ups Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Computer Ups Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40985783 Due date: 28 Jul, 202528 Jul, 2025 1.50 Crore
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a

State Government

CTN :40566562 Due date: 16 Jul, 202516 Jul, 2025 NA
Tender For corrigendum : supply of aio computer , multifunction printer , off line ups

CTN :40980174 Due date: 16 Jul, 202516 Jul, 2025 NA
Tender For providing of design installation and maintenance of educational lab - smart class lab; supply and installation of hardware; buyer - supply, install and maintain for the period of 3 years for computers ,ups , smart class solution and video wall

Central Government/Public Sector

CTN :40967414 Due date: 29 Jul, 202529 Jul, 2025 NA
Tender For supply of cms kiosk: 1. touch screen lcd/tft display,17, 2. off line 1 kva ups

CTN :40964967 Due date: 08 Jul, 202508 Jul, 2025 3.00 Lacs
Tender For computer ups 40

State Government

CTN :40919628 Due date: 20 Jul, 202520 Jul, 2025 NA
Tender For supply of desktop computer, ups, mfm printer, led tv (65inch), wireless mice & camera for virtual meeting

State Government

CTN :40771806 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For corrigendum : supply of desktop computer, ups & printer for the office of electricity test division camp office, tanakpur (champawat) under edc champawat. rates should be quoted without gst. gst paid extra as per rule.

CTN :40903317 Due date: 07 Jul, 202507 Jul, 2025 NA
Tender For supply of desktop computer , ups , key board , mouse , hdmi cable

CTN :40893741 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For sealed quotation are invited for purchase of equipment's like (computer, ups, led 65inch, printer (mfm), wireless mice and camera and internet facility) from reputed venders with proven track records.

CTN :40851562 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For dental equipments / instruments - 3 point articulator/plane articulator (mean value articulator), acryliser programmable preheating time & temperature programmable curing time & temperature analog control unit capacity-6-8 flask digital programming, adson tooth forceps 5 , adsons tooth forceps 8 , advance digital microscope with imaging software (with desktop + printer + ups + mouse) optical system- infinity color corrected optical system observation tube: seidentopf digital viewing head, 3.2 million pixels high resolution camera system resolution ratio 2048*1536 pixels, line by line scan eyepiece: high eye point wide field plan eyepiece pl10x/20mm, with 5 degrees diopter control, ipd: 50-75mm objective: plan achromatic objective 4x plan achromatic objective 10x plan achromatic objective 40x spring plan achromatic objective 100x s, oil nosepiece: backward quadruple nosepiece illumination- main supply 100v-240v, 3 watt led lamp or 6v/20w halogen with intensity control (fixed center focusing adjustment: coaxial coarse and fine focusing adjustment, with limited and tension adjustment coarse adjustment range: 25mm fine adjustment precision 0.002mm. condenser: n.a.1.25 condenser (with socket for phase contrast and dark field sliders) stage: coaxial mechanical stage 140x132mm size and 76 50mm travel range. inbuilt microscopic scientific digital camera with imaging software consisting of: high resolution digital camera with 1/2 cmos chip usb 2.0 pc connection real time live image resolution: 3 mega pixels electronic shutter exposure time: 1ms-0.3s working temperature: -20 c ~ 70 c image analysis software: sportily calibration line measurements for distance, length, width, perimeter, angle, three point radius. area by enclosed line controlled by four arrow keys available on the keyboard arrow with zoomed preview the line measurement is not affected on zoomed images. identification of objects in an image, count them, obtain several features measurements. objects identification by user or automatically. user defined classification on basis of size or intensity. manual, auto bright and auto dark methods to identify intensity range defined object to be measured. various calculation & measurements available for selected particle are; dimensions, area, perimeter, ferrite length, min/ max radius, thread length, thread width, fiber length, fiber width. roundness, shape, orientation, elongation, equal circular diameter, equal sphere volume, data export report generating and print out interactive file format., agate spatula, air conditioner, air purifier, airotor cartridge suitable for nsk airotor hand piece, airotor control box with inbuilt micromotor , 3 way syringe & 02 nos. airotor control with trolly, airotor hand piece (chuck), airotor hand piece noiseless ultra push type with ceramaic bearing super torque head, airotor oiling machine, alcohol torch with adjustable flame, alginate mixing spatula, allis forcep 5 , allis forcep 6 , alloy cutter compact alloy cutter with high speed grinding and dependable trouble free operation with vaccum suction safety glass for glare elimination and visual protection 20000 rpm, amalgam carrier, amalgamator, anesthesia machine (boyle apparatus) 1. ms & aluminum combined structure with polyurethane coated finish for long life. 2. forged body regulators for medical oxygen & nitrous oxide for maintenance free operation. 3. two numbers each forged yokes with ss fittings for medical oxygen & nitrous oxide at the sides. 4. colour coded yoke mounted high pressure gauges. 5. two tube rotameter with oxygen ratio controller with unitized rotameter. 6. magill s breathing system one number in addition. 7. bain s breathing system one number in addition 8. safety features : oxygen failure warning device (ofwd) nitrous oxide cut off in the absence of oxygen oxygen ratio controller 9. large diameter castor wheels with individual brakes at front castors 10. one year standard warranty 11. local s
 Loading, Please wait...

Connect us via What's Up