Web Analytics Made Easy - StatCounter

Concrete Permeability Machine Tenders

Get complete information related to latest Concrete Permeability Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Concrete Permeability Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Concrete Permeability Machine Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40701507 Due date: 23 Jun, 202523 Jun, 2025 1.20 Crore
Tender For construction, testing and commissioning of r.c.c. elevated service reservoir of 40kl capacities & staging 12. mt. including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber (1nos new oht, 3nos balance work of incomplete oht as per schedule)&providing, laying, jointing, interconnection, testing and commissioning of mm dia to 63 & 75 mm hdpe pe-100 , pn-6 pipe 90mm dia upvc class 6/10 kg/sqcm with suitable joints & 80 mm dia gi pipe, valve specials and all fittings including all allied civil works, supplying & installation of energy efficiant five star bee rating isi marked required capacity single & three phase, 50 hz, 220v, deep well submersible pump stainless steel body, suitable for 4"/6" tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe, ss /nylonwireropeandconnection cable including verification & electric connection from cseb, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(f.h.t.c) in individual households and government instiution etc. complete with trial run operation & maintanance for 03 months under single village of piped water supply scheme under jal jeevan mission for village- gumma ,(gp.) gumma block- chhindgarh, district sukma at risk and cost ( old sor)

Central Government/Public Sector

CTN :40693451 Due date: 18 Jun, 202518 Jun, 2025 6.20 Lacs
Tender For supply, installation, testing and commissioning of double skin ceiling suspended 4000 cfm ahu with mixing chamber vfd vav and associated works at lab wl 212

State Government

CTN :40684090 Due date: 23 Jun, 202523 Jun, 2025 NA
Tender For supply installation testing and commissioning of air conditioner system in different office chamber at environment department, 5th floor, pranisampad bhawan, salt lake, kolkata

State Government

CTN :40690718 Due date: 26 Jun, 202526 Jun, 2025 88.1 Thousand
Tender For supply, installation, testing and commissioning of ac machine with allied ei works at superintendent chamber blood donor collection room blood donor refreshment room and emergency doctor room of baruipur sub divisional hospital baruipur south 24 parganas electrical installation work

State Government

CTN :40621135 Due date: 20 Jun, 202520 Jun, 2025 1.84 Crore
Tender For corrigendum : : dnit for internal improvement works of cluster section no. 363-e (package no. 10) for water supply scheme swah wala, chak swah wala, chak saido ke (3 nos. scheme 5 nos. villages) block guruharsahai, distt. ferozepur (under state share/jjm) name of work :- "2 nos. repair of existing 75 cum ohsr, repair of existing 150 cum ohsr, disinfection unit electrically based and 2 nos. repair of existing pump chamber 3.70 x 4.30m. and construction of ihhl complete in all respects, repair of existing pump chamber 3.05 x 3.70 mtr. and construction of ihhl complete in all respects, providing, laying, cutting, jointing & testing of pvc pipe 6kg/cm2 for distribution. including cost of excavation, dismantling & relaying of dry brick on edge paving, cc flooring, house hold water connection with water meter & development of water works site etc. complete in all respect and all other works contgent there to". (completion period 6 month)

State Government

CTN :40621144 Due date: 20 Jun, 202520 Jun, 2025 1.83 Crore
Tender For corrigendum : dnit for internal improvement works of cluster section no. 362-b (package no. 3) for water supply scheme jhawla, virk khurd & kohar singh wala (3 nos. schemes & 7 nos. villages), block guruharsahai, distt. ferozepur (under state share/jjm) name of work :- "2 nos. repair of existing 150 cum ohsr, repair of existing 25 cum ohsr, disinfection unit electrically based and construction of pump chamber 3.05 x 3.70m including gravil pit and construction of ihhl complete in all respects, repair of existing pump chamber 2.50 x 2.50 mtr., repair of existing pump chamber 3.70 x 4.30 mtr., providing, laying, cutting, jointing & testing of pvc pipe 6kg/cm2 for distribution. including cost of excavation, dismantling & relaying of dry brick on edge paving and dismantling of metalled road, cc flooring, house hold water connection with water meter & development of water works site etc. complete in all respect and all other works contgent there to". (completion period 6 month)

CTN :40691211 Due date: 19 Jun, 202519 Jun, 2025 2.97 Lacs
Tender For repair maintenance of of various e&m services installed in 1st & 2nd mso buildings, cg hostel and residential quarters in nizam palace campus, kolkata. (s.h.:- supply, installation, testing and commissioning of new cassette type split ac units in the chamber of chief engineer (w&tlqa) 5th floor, 1st mso building.)

CTN :40711987 Due date: 01 Jul, 202501 Jul, 2025 8.00 Lacs
Tender For supply, installation and commissioning of conditioning chamber, communicable insulation resistance meter, hot set test set and ct and pt for distribution transformer testing

CTN :40378817 Due date: 19 Jun, 202519 Jun, 2025 NA
Tender For corrigendum : supply installation commissioning of chemistry lab at item wise on turnkey basis at govt new model college jhabua - supply installation of chemistry lab equipment on turnkey basis, analytical weight box 100 gm, chemical balance, chromatography cabinet 6 leaves, digital conductivity meter, digital potentiometer, distillation app.singlecap 5 litre, electronic digital balancecap.0.01gm-600g, kippsapp, magnetic stirrer with hot plate, meltingpoint app, vortexshaker, water & soil testing kit digital, water bath 6 hole double walled s.s.chamber, tlc kit with applicator, digital spectrophotometer 340nm-960nm, digital ph meter with electrode

CTN :40655550 Due date: 01 Jul, 202501 Jul, 2025 NA
Tender For acoustic design - walls: area: 81.3 sqm / approx. 876 sq feetsupply and fixing of polyethylene terephthalate made from light weight, eco-friendly, sustainable 100% polyester fibers (60% pet-recycled fiber, 40% pet-virgin fibre). the panels should be having a thickness of 10mm which is tested for the sac (sound absorption coefficient) in any third-party lab such as arai (govt., of india) according to type a mounting. the vendor should present the third-party compliance by furnishing third-party lab test reports for the product proposed and should clearly mention test details which is carried out in a national accreditation board for testing and calibration laboratories (nabl) certified lab mentioning above test standards and should comply strict adherence with the specification. these panels should be having a density in the range of 180 - 200kg/m3, 10mm thick with fr treatment and third-party certified for astm c-423 to give an nrc up to 0.30 - 0.35. minimum 10mm pet panels - prefabricated acoustic panels are to be pasted directly on to the wall using high quality adhesives in the required area., secondary layer absorbtion: area: 13.68 sq m/approx. 148 sq. feetsupply & fixing of acoustic panels using core material of 100% polyester fibers (60% pet-recycled fiber, 40% pet-virgin fibre). the acoustic core used in these panels should have a minimum density of 120kg/m3, 40mm thick with fr treatment and should demonstrate third party compliance to for astm e-84 for the acoustic core when tested in any nabl certified lab. strict adherence with the specification is to be demonstrated in the way of submitted third party test qualification. edges of the acoustic panels should be hardened and concealed having fabric facing without any wooden or plywood strips used at the edges since it can cause termite issues in the future. the system should be fixed on the 10mm pet panels prefab acoustic panels fixed directly on the walls using z-clips. the facing side should be lined with a non-woven acoustic fleece or acoustic fabric lined which can allow the smooth flow of the sound energy at the same time should not allow any fibers, dust or shot content migration through the acoustic infill. the panels sizes are to be considered as 1200 mm x 600 mm which are placed randomly at a specific spacing spread across the left side & right-side walls. special consideration to be done to avoid usage of any glass wool or rockwool materials inside the class to avoid any fiber migration. the product should be tested for the sac (sound absorption coefficient) in any reputed lab globally to achieve a minimum nrc of 0.95 when tested according to astm c423/iso 354 standard on type a mounting method during the random incidence test in the chamber. the core used should pass the cdph v1.2 test standard for low voc emissions and can contribute to leed v4.1 eq credit: low-emitting materials. the product should also qualify when tested according to astm c 1338-08 for determining the fungal resistance of insulation materials and facings. the product should also be tested for the reflectance factor according to the astm e1447-2017 and the supplier should be able to furnish the third-party lab test reports for all the above-mentioned test standards., ceiling tiles 44 sqm/approx. 474 sq. feetsupply and installation of polyester fiber acoustic ceiling tiles measuring 2ft x 2ft, flat and rigid, made from lightweight, eco-friendly, and sustainable 100% polyester fibers (60% pet-recycled fiber and 40% pet-virgin fiber). the tiles should have a minimum thickness of 15mm and be fixed onto the existing t-grid system after the removal of the current tiles on-site. the facing side of the tiles should be lined with a non-woven acoustic fleece or acoustic fabric. the acoustic core must have a minimum density of 120 kg/m , with a 15mm thick polyester core that is fr-treated and third-party certified for astm e-84 fire safety compliance. the product must be tested for the sound
 Loading, Please wait...

Connect us via What's Up