Get complete information related to latest Condenser Fan Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Condenser Fan Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Condenser Fan Tenders.
Tender For supply of 1. goods, amit make hvac spare refrigerant side glass for vande bharat as per rdso specification.2. vb trainset amit make hvac spare fresh air filters for vande bharat as per rdso specification.3. vb trainset amit make hvac spare filter drier for vande bharat as per rdso specification.4. b trainset amit make hvac spare hp cut out for vande bharat as per rdso specification.5.vb trainset amit make hvac spare ohp (danfos make) for vande bharat as per rdso specification.6.good,amit make hvac spare hand shut off valve for vande bharat as per rdso specification.7. goods, amit make hvac spare brass distributor for cooling coil for vande bharat as per rdso specification.8. vb trainset amit make hvac spare transducer lp for vande bharat as per rdso specification.9. vb trainset amit make hvac spare condenserfan blade (630 dia and 8 blades) asper rdso specification.10. goods, amit make hvac spare switch on/off as per rdso specification.11. vb trainset amit make hvac spare phase sequence relay as per rdso specification.12. goods, amit make hvac spare contactor blower as per rdso specification.13. goods amit make hvac spare fresh air sensors (ntc) as per rdso specification .14. amit make hvac spare return air sensors (ntc) as per rdsospecification.15. goods, amit make hvac spare pressure transmitter (transducer) lp: 0-10 bar as per rdso specification.
Tender For supply of condenserfan motor for roof mounted air conditioning system for three phase locomotives. rating - 0.15/0.2 kw/hp, rpm 1360, frame 63 and as per rdso's spec. no. rdso/pe/spec/ac/0089 (rev. - 0) 2008 with amendment 1 & 2.
Tender For providing of custom bid for services - 9070c25d17 rewinding of condenserfan single phase motors of precision vrf package ac and non precision duct able type package acs installed at various locations within paradip refinery and township area odisha
Tender For supply of wind shield glass , clutch cylinder assy , water seperator , slave cyl assy , air bag safty dvr side , air bag safty co-dvr side , hub front , ac condenser , ac compressor , condenserfan
Tender For supply of rectifier blower motor dc (condenserfan [rectifier blower motor dc (condenserfan motor dc), as per elgi electric make model fmd 112 nc5, with 19mm shaft dia, without blower , type -comp,1kw , 110 v dc, 12.25 amps, rpm-2000, suitable for 700 & 1400 hp demu dpc. confirming to icf specification no.icf/elec/825/rev-1, cs no. 3, or latest.]
Tender For vgtps/ph-ii/rmd/electrical maintenance – labour charges for laying, releasing & both end termination of 116 mtrs of 3 core *185 sqmm aluminum armoured lt power cable from pmcc-ii (17f3) to air cooled condenserfan motor # 8 motor, 125 mtrs of 3 core *185 sqmm aluminum armoured lt power cable from pmcc-ii (12r4) to vacuum pump motor # 2 and 59 mtrs each of 4 core*120 sqmm lt aluminum armored power cable from a/c ventilation mcc (4f4 & 6f4) to a/c compressor motor #1 & 2 in respect of electrical maintenance sub division/ph-ii/vgtps
Tender For replacement of em items against ber held with ge i rnd east bangalore - supply, installation, testing & commissioning of double skin horizontal air handling unit of fully capacity, complete with double skin insulated with cfc free foam (puf) panels of 25mm thick, 42 kg/cum density. sandwitched between 0.6 mm thick g.i. sheets. outer skin shall be pre coated g.i. sheet pre coated off white. ahu frame works shall be of pre cast vertical and horizontal extruded aluminium profile with three way corner frame sections. frame construction should bear the load of structure and load of the frame structure shall be uniformly distributed along the entire housing of the ahu. food grade self adhesive coated neoprene gasket to be provided between panels and structure of the ahu to ensure the entire housing is airtight., backward curved blower to be supplied along with motor (kruger/nicotra). filter will be of 10 mic as pre filter, 3 mic as fine filter. cfm as below with 60-80mm sp complete all as specified and directed., note: rate quoted to be deemed to include civil works for hvac like breaking and opening for entry and exit of supply ducts from ahu room, exhaust ducts into shafts for exiting copper pipes / drain pipes also. fire rated material of 25mm thick phenotherm to be used near civil closures for fire resistant properties., a) 13200 cfm, 60mm static ahu capacity 33 tr., 11 tr dx outdoor ac unit complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenserfans with eco friendly r410 refrigerant & powder coated outer metal body controlling a minimum capacity.note: rate quoted to be deemed to erection of condenser unit platform (ms angle frame with 02 coats of red-oxide and 01 coat of enamel black paint) with ms works for duct support., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenserfans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 22 tr ducted packaged ac unit with 8800cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenserfans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 11 tr ducted packaged ac unit with 4400cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenserfans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 8.5 tr ducted packaged ac unit with 3500cfm complete all as specified and directed., supply, installation, testing & commissioning of air cooled ducted split air conditioners of capacity 8.5 tr with r2 series: r 407c eco friendly refrigerant, nominal cooling capacity 1,02,000 btu/hr, nominal air flow 3400 cfm, microprocessor based with lcd display controller and hermetically sealed scroll type compressor, all necessary connections with suitable size of copper cables and initial gas charging, provision of necessary pcc platform / iron angle frame for outdoor unit complete all as specified and directed by engineer-in-charge., dismantling / taking down / transporting carefully old acs outdoor & indoor unit with all connected acessories and to be deposited in mes store complete all as specified and directed., dismantling / taking down / transporting carefully old unserviceable ducting items off any size and capacity with all connected accessories and to be deposited i