Web Analytics Made Easy - StatCounter

Conductor Laying Tenders

Get complete information related to latest Conductor Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Conductor Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Conductor Laying Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :38802188 Due date: 20 Jan, 202520 Jan, 2025 NA
Tender For corrigendum : tender for supply of supply of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexureiii-a , supply of cassette ac four way capacity 3 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure iii-a , supply of cassette ac four way capacity 4 tr rating inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure iii-a , supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4tr cassette acorsplit ac unit refer annexureiii-a , providing flexible pvc duct hose covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte ac units refer aneexure iii-a , providingcpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureiii-a , providing cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexureiii-a , supply of rain proof outdoor duty as per ip-66 electrical control panel with incommer 4 pole mccb 100 amp digital voltmeter digital ammeter indication lamps refer annexureiii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 4 sqmm refer annexureiii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 6 sqmm refer annexureiii-a , supply of following size lt power cable with copper conductor laying of the same in by eic 4core - 25 sqmm refer annexure-iii-a , supply of following size lt power cable with copper conductor as directed by eic 4core - 16 sqmm refer annexure-iii-a , supply of copper cable of size 4core - 2point5 sqmm for communication , supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness , supply of perforated hot dipped galvanised iron cable tray of size 300 mm width x 50 mm depth x 1point6 mm thickness , installation testing and commissioning of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotaryorscroll compressor aircooled refer annexure-iii-b , installationtesting and commissioning of cassette ac four way capacity 3 tr minimum 3 star rating inverter type refer annexure-iii-b , installation testing and commissioning of cassette ac four way capacity 4 tr inverter type rotary or scroll compressor units refer annexure-iii-b , erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4tr cassette acorsplit ac unit refer annexure-iii-b , laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable refer annexure-iii-b , laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexure-iii-b , laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-iii-b , erection testing and commissioning of rain proof outdoor duty as per ip-66 electrical control panel annexure-iii-b , laying of following size lt power cable with copper conductor xlpepvc insulation pvc inner sheathed armoured extruded pvc oas directed by eic 4 core - 4 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conductor xlpeorpvc insulation as directed by eic 4 core - 6 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conducto as directed by eic 4 core - 25 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conductor xlpeorpvcas directed by eic 4 core - 16 sqmm refer annexure-iii-b , laying of copper cable of size 4 core - 2point5 sqmm for communication , installing of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness

Central Government/Public Sector

CTN :38770637 Due date: 22 Jan, 202522 Jan, 2025 NA
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; cable tray design new cable tray erection 11kv new cable laying cable termination and old cable removal, electrical system or installation; service provid..

Central Government/Public Sector

CTN :38587466 Due date: 20 Jan, 202520 Jan, 2025 19.66 Lacs
Tender For corrigendum : repair, maintenance, and installation of plant/ systems/equipments (version 2) - 285 instrument erection contract for revamping of flow lab at instrument workshop at rcf trombay unit; as per sow; as per sow- 1 fabrication, erection & installation of cable tray 50 mm width with necessary support m s angle 50 mm. this job includes two coat of primer and two coat of anticorrasiveepoxy coats. supply of primer and paint to be included and fabrication, erection and installation of cable tray. 50 mtr, 2 supply and installation side mounted glass tube level indicator approx 2.5 mtr length with high and low level switch adjustable over the full length. 1 no, 3 supply and installation and commissioning of centrifugal pump flow capacity of 30 m3/hr head 45 meter suitable for vfd drive 1 no, 4 magnetic flow meter 0 to 50 m3 /hr, 4" size flanged 150# rf, accuracy 0.1% with calibration certificate 1 no, 5 4" size ss material, 150#, flanged on/off valves with actuator, limit switch indication dome, solenoid valve 4 no, 6 vfd with panel and start /stop pb, and speed control 1 no, 7 pressure gauges 1 no, 8 supply, installation of piping suitable for the flow skid in sizes 4" and as per requirement 1 lot, 9 flow totalizer with contacts and set rest function 1 no, 10 panel for skid operation with pb, lamps, selector switch 1 no, 11 supply, installation of pvc coated cu tubing with necessary fittings for 4 valves 80 mtr, 12 supply, installation of air distribution header 6 points stainless steel 1 no, 13 supply, installation of 50 mm wide x 30 mm x 2 mm thick gi cable tray 100 mtr., 14 supply, installation of 100 mm wide x 30 mm x 2 mm thick gi cable tray 100 mtr., 15 supply, installation of layingof signal and power cables 300 mtr., 16 1 pair x 1.5 mm2 signal cable 300 mtr., 17 power cable for motor existing cable to be reused as per requirement 500 mtr, 18 spool pieces with one end flanged connection and other end with triclover coupling in ss304 of various sizes as below with 10d and 5d lengths. set of spool pieces shall iclude following sizes: 6", 4", 3", 2.5", 2", 1.5", 1", 3/4", 1/2" each in quantity 2 numbers 1 lot removal jobs 1 structural steel which includes ms ladder tray, stantion, alluminium cable trays 300 kg, 2 cable- signal , power cable removal 100 mtr., 3 level indicator 2 no, 4 existing piping and fittings 1 lot, 5 removal of existing pipe and fittings 1 lot

Central Government/Public Sector

CTN :38769905 Due date: 19 Jan, 202519 Jan, 2025 NA
Tender For spl repair/ replacement of electric supply installations, cable tray, apfc panels, xlpe cables and other connected accessories at kashmir house under ge new delhi
 Loading, Please wait...

Connect us via What's Up