Get complete information related to latest Control Panel Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Control Panel Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Control Panel Switch Tenders.
Tender For supply of lt air circuit breaker 1000a do type , lt air circuit breaker 4000a do type , hrc fuse holder upto 20a ns type , spare handle cssdf 32a 160a moulded , spare handle cssdf 200a 400a moulded , spare handle shaft cssdf 32a 160a , castle key locks cssdf 200a 800a , spare poles per pole 63a , spare poles per pole 400a , spare neutral links cssdf 200a 400a , charging motors 20d 40d 30s 40s aha , exceed 3 pole power contacto 1no 1nc 65a , power contactors 250 a 3 pole , closing coil 6d 16d , closing coil 20 40d , shunt trip 6 16d , shunt trip 20 40d , auxiliary switch 5 way 3no 2nc 20 40 , auxiliary switch 5 way 3no 2nc 6 16d , control relays 10 amps with dc coil , control relays 10 amps 2 no 2nc , control relays 10 amps 3 no 1nc , control relays 10 amps 4no with dc , push button with 2no block equivalent , push button stay put press to lock , mechanical operation counter cs wm2 asc , safety shutter 6d 16d 06n 16n 3 pole , 40d 3 pole ash 4 safety shutter assly , 6d 16d 06n 20s cs axh 7a7b 116 auxiliary , 20d 40d 25n 40s 50c 60c cs axh 7a7b 22 , 6d 8d 06n 10n cs arccont 08d arcing cont , 10d 12 d 12 n cs arccont 12d arcing cont , 40d cs arccont 40d arcing contacts upgra , 10d 12 d 12 n fixcont 10d 12 d 1 main , 40d fixcont 40d 1 main fixed contacts , 6d 16d 06n 20n arc contact , 40d cs arccht 40d 1 arc chutes upgraded , anti pumping relay 6d 16d 06n 20s 3p cs , 3p cs anti pump relay , manual charging handle 6 16d , manual charging handle 20 40d , draw out handle 6 16d , draw out handle 20 40d , cclimsw closing coil limit switch , plastic front cover gray d type , castle key locks , spare neutral links , 100a 160a cssdfzx86 spare neutral links , 200a 400a cssdfzx85 spare neutral links , module rack in out assembly set pvc , module rail set left side fixed and movin , module rail set right side fixed and movi , module door hinge fixed and moving , panel door hinge left upgraded , panel door black spindle door knob , module door facia small upgrade , module door facia medium upgraded , vertical busbar support insulator big , vertical busbar support insulator small , busbar support insulator 3 way upgraded , busbar support insulator 2 way upgraded , busbar support round insulator 40mm , module control sliding terminal set , module plug in control terminal set , fix power terminal male vertical bus 125 , fix power terminal male vertical bus 250 , fix power terminal male vertical bus 400 , moving outgoing side female term 80 125 , moving outgoing side female term 250 , moving outgoing side female trolley term , fixed outgoing side male terminal 80 , fixed outgoing side male terminal 250 , fixed outgoing side male terminal 400 , phase barrier 3pole fixed upgraded e , position indication switch upgraded equ , switch disconnector fuse unit 125 a , switch disconnector fuse unit 160a , exceed 3 pole power contacto 1no 1nc 50a
Tender For hiring of 01 no. 260 mt capacity tyre mounted lattice boom crane with luffing jib, safe load indicator (sli), limit switch and other necessary operational accessories and safety features including operator, mechanic and helper in connection with sil
Tender For purchase of equipments - purchase of equipment, bench top glass insitu airlift photo bioreactor1. vessel capacity: 3 liter borosilicate glass (working volume: two to three liters maximum), vessel hxd ratio 4:1 (400x100mm)2. head plate & bottom plate moc: ss 316l3. ports in top plate: ph sensor; dissolved oxygen (do) sensor; pressure sensor; air in and draft tube; air out; acid/base; sampling; and addition port.4. mixing method: ring sparger to create airlift circulation inside the reactor for uniform mixing and better aeration.5. holders for sensor /adapter / blind stoppers in head plate: ph sensor holder; media double inlet for acid/base dosing; air sparger - ring type for airlift application without stirring, air out with exhaust filter and open/close valve; pressure sensor holder; sampling pipe; blind stopper for un used port; unique suitable ss puncturing needles for sampling, air in, air out, inoculum, feed addition.6. ports in bottom plate with stand: port for temperature sensor; heating finger u-tube heat exchanger; drain.7. holders for sensor / adapter / blind stoppers in bottom plate: holder for temperature sensor, heating finger, u-tube heat exchanger.8. sensors: temperature, gel filled sterilizable ph sensor, & pressure sensor.9. controls and display: modular independent system of ph, temperature, pressure with touch screen graphical display & control; two set point control of ph with three-point buffer auto calibration; aeration by flow meter 0-5lpm with air pump; sterilization controls up to 121 without steam generator along with pressure safety mechanism by independent pressure sensor and digital display & control; automatic digital pressure safety and over temperature safety cutoff and alarm; upgradable control system for future prospective as cstr reactor & dissolved oxygen (do).10. measurement and control range: ph: 2-14; process temperature: 20 to 60 ; sterilization temperature: up to 121 ; and pressure up to 15 psi.11. fixed speed peristaltic pump: for acid/base dosing with teflon non spring head. (2 nos)12. cooling system: chiller cum circulator. chiller temperature range 4 to 40 , bath capacity 5l to cool down the reactor after sterilization and to work process temperature below ambient condition.13. illumination system: two illumination assembly with variable intensity control (1000-3000 lux) around the reactor with independent controlswitch for photobioreactor, or other application and easy detachable if not in use. 14. essential accessories : silicon tubing for acid/base addition (10m); air in and sampling (10m); water circulation (5m); air vent filters 0.2 micron sterilizable (6nos); and silicon septum (25nos)15. starter kit: spare silicon-o-rings for head plate, bottom plate (1no each), all other ports (5nos each), alen key.16. warranty: one year17. support (must): unconditional onsite technical support shall be provided as and when needed. the supplier must provide complete installation and hands-on demonstration of the equipment at the user site upon delivery.18. the vendor should have a registered presence in india with an authorized local service provider in tamil nadu.
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t