Tender For supply of procurement of ilms spares d d - part no. ez230126746701 magnet coil , part no. ez230126746709 geard coupling rg 02 , part no. ez230126746725 zss prs , part no. ez2404427467e07 21.5kva 3 ph tr wth tapping in pr and sec , part no. ez2404427467e10 70 amps bridge rectifiare , part no. ez2404427467e18 500 va 415 110v , 1 phase control tr , part no. ez2404427467e05 32a t p air break power cont 3 no plus 1 nc , part no. ez2404427467e22 aux relay wth 3no plus 1nc contact c.v.110vac , part no. ez2404427467e27 dc current sensing relay , part no. ez2404427467e28 temperature controller , part no. ez2404427467e11 0 300 v pmmc voltmeter for dc , part no. ez2404427467e17 0.5 60 sec on delay timer contact 110 vc , part no. ez2404427467e02 r y b indicating led 110 ac
Tender For supply of part no. ez230126746701 magnet coil , part no. ez230126746709 geard coupling rg 02 , part no. ez230126746725 zss prs , part no. ez2404427467e07 21.5kva 3 ph tr wth tapping in pr and sec , part no. ez2404427467e10 70 amps bridge rectifiare , part no. ez2404427467e18 500 va 415 110v , 1 phase control tr , part no. ez2404427467e05 32a t p air break power cont 3 no plus 1 nc , part no. ez2404427467e22 aux relay wth 3no plus 1nc contact c.v.110vac , part no. ez2404427467e27 dc current sensing relay , part no. ez2404427467e28 temperature controller , part no. ez2404427467e11 0 300 v pmmc voltmeter for dc , part no. ez2404427467e17 0.5 60 sec on delay timer contact 110 vc , part no. ez2404427467e02 r y b indicating led 110 ac
Tender For supply of multimeter and other instrument - digital multimeter 6000 counts lcd display 3.5 digit with a pleasant white backlight. ac/ dc current range up to 20a. resistance, capacitance, diode & continuity measurement facility. selectable frequency & duty cycle measurement. highly linear readings. select, range, hold/light, rel, hz/duty. max/min function incorporated. safety ce, cat iv (600v), ip 54, en 61326-1 & iec 61010-1, robust, rugged & double mold casing. operating temperature : 0 c to 50 c , accuracyaccuracy is specified as (% of reading + digits), ac voltage accuracy (1% + 3), dc voltage accuracy (0.25% + 3), ac current accuracy (1.5% + 5), dc current accuracy (1.2% + 5), resistance accuracy up to 600 k (0.5% + 3), safety- directives for ce certification : lvd:2006/95/ec., emc: 2004/104/ec measurement category : cat iii, (1000v) reinforced insulation. relevant standard specification : en 61010-1:2010, en 61326-1:2006, ip rating (dust & water protection) : ip 54, overload protection, fuse protection for a & : 0.8 a/ 250v fast blow type ceramic fuse. ma input terminal, fuse protection for 10a : 20a/ 500v fast blow type ceramic fuse input terminal. / / / / /hz(%) : 440 v dc / ac rms., digital clamp meter model dcm details: measure current upto 300 a, voltage range (v) 500 mv to 1000 v, operating temperature ( c):-10 c to +50 c storage temperature ( c): -40 c to + 60 c safety ip rating iec 61010-1, digital multimete r 4.5 digit details: 1. digital multimeter 2. auto 3. manual 4. 1kv ac/dc 5. 10a ac/dc 6. true rms 7. 19999 count 8. 4.5 digit, hydogen leak detector details: sensor for hydrogen gas leak detector system: ceiling mounted type, sensing covering area: 3-4 meter in diameter, operating temp: 0 c to 55 c, accuracy: +/- 0.4 % of h2 for 4 % max h2, response time: 3 sec, power supply: 24 vdc, 80ma max, with all necess such as signal cable, fixing screw etc
Tender For supply of ffd1 a ac input fuse fail detector circuit, mt 111, 415v12v dc , con101 a 3 pole ac input mains contactor, mnx 70 cs97076booo,63a,230v ac 70a , tr2a control transformer class b insulation with temperature rise class a 415240v ac, 500va , converter 1a,2a ac to dc converter,lrs 100 48 , ip 230vac, op 48v dc2.3a , tr1a three phase, double wound, impregnated naturally air cooled, mains transformer class h insulation and temperature rise limited to class f, input power transformer,32.15 kva, 45670v, 70v , ipt 1a inter phase transformer,0.65kva , ffd2a 3a, rectifier fuse fail detector circuit modified for latching facility using one extra relay and pb mounted on same pcb card used for trip function, mt 111,70v ac, aux. supply 12v dc , mr1a 2a 3 phase, full controlled, full wave rectifier bridge comprising of scr with heat sink and surge suppression networkt250e160,scr 170a1600 piv, 250a1600 piv , df a free wheeling diode,150nd160,150a1600piv , ffd5a free wheeling diode fuse fail detector circuit modified for latching facility using one extra relayand pb mounted on same pcb. card used for trip functionmt 111,48v ac, aux supply 12v dc , rc pcb,mt 116 , ch1a, filter choke dc choke , 48325a , ffd 4a, filter capacitor fuse fail detector circuit modified for latching facility using one extra relayand pb mounted on same pcb. card used for trip functionmt 111,48v ac, aux supply 12v dc , cpc1a 2a,3 phase full controlled card with green connector 6 pulse ,mt 103,48v cv cc , hvandpf psr card 1a 2a,high voltage and phase failphase reversal circuit with control transformer 456v18 0 18v, 50va,mt 105,415v ac , dc ov 1a,charger dc over voltage circuit of solid state sensing type with external rl card including 1k ohm50w resistor,mt 106 actuating voltage 54.5v , resetting voltage 53v , dc ov 2a,charger dc over voltage circuit of solid state sensing type with external rl card including 1k ohm50w resistor,mt 106 actuating voltage 66.5v ,resetting voltage 65v , mr3a,charger silicon blocker diode 2nos. in parallel ,250ng160,250a1600 piv , cb 901a3 pole moulded case circuit breaker mccb for dc output including aux switch for cb901a and shunt trip coil du400ncm98402ooro ,400a, 15ka 50ka ,suitable range 0.8 1 , clc 1abattery current limiting circuitmt 110,240v ac, act 45a , load on batt 1a,battery current sensing circuit for battery on load alarmmt 110, 12 v dc, act 8a , load on batt 2a,battery current sensing circuit for battery on load trip function,mt 156, 12 v dc, act 10a , 12v ps 3 4a12v power supply for 12v control supplyurb4812ld 30wr3a4s,ip 18 75vdc op 12vdc2500ma , mcu1001a1 1a,monitoring and controlling unit mcu ,20 80v dc , annunciator 1a,12 window annunciator with labels,ae48260vacdcdw04sw08rs485,aux. sup 48v dc ,with rs485 output , batt uv 1a battery under voltage circuit of solid state sensing type including 1 k ohm 50w resistor ,mt 106 actuating voltage 43.7 v, resetting voltage 45 v , 24v ps 1c 2c,24v power supply for con 901 902 of standby charger ,lrs 150 24,24v dc , con 901, 901n, 1 pole dc contactor with 1 no aux. evd400g1da4 ,400a, 12 36 v dc coil , ol 1a, thermal over load relay for contactor, range 30 50a mnx 50 ss94136oogo mn5
Tender For corrigendum : procurement of electrical components and minor equipment for lab at nitanp.-, , three- phase voltage sensors (used for both ac and dc sensing capability) with high accuracy along with dso probes , , three- phase current sensors (used for both ac and dc sensing capability) with high accuracy along with dso probes , , powering boards for sensors and gate driver circuits (15v, 12v, 5v) , , lsr-600-12 dc power supply/ smps mean well 12v, 50a, 600w , , lsr-600-15 dc power supply/ smps mean well 15v, 40a, 600w , , lsr-600-24 dc power supply/ smps mean well 24v, 25a, 600w , , lsr-600-36 dc power supply/ smps mean well 36v, 16.6a, 600w , , lsr-600-48 dc power supply/ smps mean well 48v, 12.5a, 600w , , skkt 107/16e - thyristors modules (1.6kv, 119a) , , scr module heat sink , , scr firing module , , inductor filter (50a) , , mccb (60a) , , ganged potentiometer (5k ohm, 3 watt) , , digital panel mount ammeter (75a) , , digital panel mount voltmeter (1000v) , , 10sq.mm wire , , dc shunt (75mv, 75a) , , lugs , , hardware (base plate for scr module) , , single-phase auto transformer (0-270v, 35a) , , three--phase auto transformer (0-440v, 40a) , , soldering iron with controllable temperature - medium (weller) , , gsr 120-li small rechargeable driller (bosch) , , fluke multi-meter (0-600v, 0-10a) , , rheostat (200 ohms, 20a) , , tektronix a622 ac/dc current probe ,
Tender For supply of power supply model no-s8vt-f12024e, input voltage 400-500vac, output voltage 24 vdc, output current , high speed, high accuracy eddy current displacement sensor, type= gp-x10m, sensing range 0 to 2 mm