Tender For supply of access switch type i , access switch type ii , access switch type iii , switch management license , indoor wireless access point type i , wireless ap management license per access point , 80 kva ups for academic block a , smf battery 12v 65ah exide or amaron 30 minutes baterry back up to 2 by 40 kva ups , battery circuit breaker , battery rack bolted to house upto 68 nos of 65ah battery floor mount , kit battery cable links for 65 ah 34 blocks , cable nyvin 1 core size 10 white 660 1100 v grade as required , 32u floor mount rack , online ups system 20 kva ups rack mount , parallel cable 2 mtrs for ita2 6 by 10 by 20 kva ups , 65 ah 230 volt battery , u6 nyvin cables for battery interlink for 16 nos battery per meter , u8 10 sqmm nyvin cables , u4 16 sqmm nyvin cables , 16 sqmm copper single core cables for earthing , 160 amp mccb , 100 amp mccb , supply of cat 6a u or utp or stp 23 awg cable etl verified lszh 332 3 roll of 305 mtrs , sitc of cat6 or cat6a field termination plug toolless type ip 20 , sitc of fiber liu 12f 1u drawer shelf factory assembled with lc sm os2 pigtails adapters etc , sitc of outdoor fiber optic joint closure dome and base type with mechanical seals ip68 rated outdoor suitable for up to 48f splice , sitc of equipment rack 15 u wall mount rack 600mmd by 700mm w dual section , electrical items required for connecting racks in every floors of hostels to centralized 10 kva ups etc , supply and fixing of pvc conduit 25 mm , supply and fixing of pvc conduit 32 mm , laying or pulling of utp cat6a cable inside pvc conduit or casing , supply of gi pipe or conduit 64 mm 2 inch of 6 meter length at 5 road crossing enroute , trenching for laying ofc underground , supply and laying or fixing of 40 mm dia hdpe pipe
Tender For collection of meter reading from consumer premises and delivery of energy bill to the consumers premises and spot billing along with serving of notice to the defaulting consumers within the jurisdiction of electrical division ranirbazarfor 12(tw
Tender For collection of meter reading from consumer premises and delivery of energy bill to the consumers premises and spot energy billing along with serving of notices to the defaulting consumers within the jurisdiction of electrical divn udaipur for 12 month
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For tender for supply of enm electrical spares item - potential transformer 11kv110v heavy du , volt meter range 0 11kv analog , square , ampere meter range 0 150a analog square , current ratio 100 50 5 5a suitable for fitting in vcb , relay erth lkge 15a prmry 0 5a primary side calibration and fitting required , potential transformer 11kv 110v 3ph
Tender For supply of spanner combination pack of 23 , torque wrench , electrical insulation rubber mat size 1x1 meter , heavy duty double wheeled bench grinder , electric change over switches 100a 415v 4 pole , high voltage resistant electrician work gloves , electric planer 650w , metal drill bit set of 10pc , electric impact drill machine 600w , dc voltage detector for veh , digital vernier caliper 0 to 150mm , measuring tape , ac dc clamp meter
Tender For tender for supply of electrical items - 20/36 watt led tube fitting , non integral type , 4x1 feet length having minimum luminous efficacy of 3600 lumen/watt , 9/10 w led lamp having minimum luminous efficacy of 100 lumen/ watt , 90-95 watt led street light luminaire with ip 66 protection and having minimum luminous etticacy 120 lumen/watt , 40-45 watt led post top lumiaire with ip 65 protection , 12 watt recessed/ surface mounted round led light fitting , having luminous efficacy of minimum 199 lm/w , 100 watt led flood light luminaire with ip 66 protection and having minimum luminous efficacy 120 lumen/watt. , surface/recess mounted 600x600 mm led light fitting , 36 watt having/luminous efficacy , recessed/ surface mounted round led light fitting , 18 watt having luminous efficacy of minimum 100 lm/w , 450 mm sweep pvc blade wall fan (heavy duty) , 1200 mm sweep bee e star rated , ceilling fan with brush less direct current (bldc) motor , 225 mm sweep light duty metallic body exhaust fan including louvers , fancy wall bracket fitting along with 9w retrofit led lamp , 5/6 a modular switch , 15/16 a modular switch , 3 pin 5/6 amp socket outlet , 6 pin 15/16 amp socket outlet , ac starter switch 25 amp , 5/6 a , 3-modular switch socket combined box , 5/6 amp , 3-pin plug top , 15/16 amp 3-pin plug top , stepped type modular fan regulator (2m) , call bell , modular call bell pushy , iron screw 40 mmx 6 mm , pvc gitti (1.5 inch) , cable clip with metal nails (8/10/12 mm) , casing capping (25x16 mm) , 1 sq. mm frlsh copper wire , 90 metre roll , 1.5 sq. mm. frls copper wire , 90 metre roll , 2.5 sq. mm frls copper wire , 90 metre roll , 4 sq. mm. fels copper wire , 90 metre roll , 3- core 6 sq. mm btc cable , 3-core , 1.5 sq. mm unarmoured copper cable , 3-core , 2.5. sq. mm unarmoured copper cable , 3-core , 4 sq. mm unarmoured copper cable , 6 - 32 amps single pole c miniature circuit breaker , 2.5 mfd fan capacitor , 3.15 mfd fan capacitor , pvc black tape , ampere tape/ bitumen tape , 33 kv lightening arrestor gl clamps bolts and nuts with washers , 36 kv 20 ka , class - 1 , 50 hz , 33 kv pin insulator with pin washers and nuts , 33 kv drop out fuse element , 63 amp , single phase energy meter , 5-30 amp , 3- phase energy meter , 10-60 amp , 9-10 watt led mirror light fiting having luminous efficacy of minimum 100 lm/watt , heating element of 15/25 ltrs capcity water heater , brass batten holder , 15/16 a , 3- modular switch socket combined box , 2 pin male female adapter plug top , casing pin , 6 mm x 75 mm steel fastner , 40 amps dp c miniature circuit breaker , 63 amps tpn c curve , miniature circuit breaker , 20 a wire connector , 400 amps , 33 kv drop out fuse connector