Get complete information related to latest Cooler Blower Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cooler Blower Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cooler Blower Spares Tenders.
Tender For fabrication and erection - boiler house, dismantling, fabrication & erection of aph outlet cane to match the size of cane with esp nozzle inlet size, dis, fab & ere of air heater expansion bellow, dis, fabrication and erection of id fan upper & lower casing, dismantling, fabrication & erection of drum type rotary bagasse feeder (with shalf), dismantling, fabrication & erection of screw feeder, dismantling, fabrication & erection of screw feeder casing., fabrication & erection of man hole, fabrication & erection of pneumatic spreader assembly from 8mm thk. s.s. plate with fabrication & erection of deflector plate from 20mm thk. s.s. plate with top & bottom flange , dismantling of old pneumatic spreader assembly & internal deflector plate, 1.5 kg/cm2 prds, exhaust & vapour pipeline fabrication & erection from 10mm thk. m. s. plate, boiling house, platform work at various stations such as mill house, boiler, turbine,cranes, boiling house, c/f house etc. if required any where., fab & erection of double filteration system for quad & water inlet pipe in pan condenser., fabrication of electric motor cover., dis,fab & ere of final molasses pipeline, fab & erecdtion of m.s.vessels, square & rectangular tank, fab & erection of m.s.plate work, dis,fab & ere of coil(water,juice,ammonia,so2etc), fab and erection of motor bed, dismentling, fabrication & erection of perforated m.s plates of direct contact juice heaters., dismentling , fabrication & erection of strainers of injection, spray , c.t pumps., fabrication of exhaust valve casing, gutter work (bigger side will be treated as dia.), gutter work dismantling, gutter work fabrication, gutter work erection, fabrication / strenghting of beam, vessel, pipe, channel, angle etc., dismantling of m.s plate, dismantling, fabrication & erection of cone as per requirement, dismantling, fabrication & erection of spray pond header, dismantling, fabrication & erection of down tape of evaporator bodies, fabrication & erection of molasses jacket for batch type c/f m/c, dismantling, fabrication & erection of various stations for entertainment catcher, dismantling fabrication & erection vapour/exhaust line from quad to pan station, dismantling, fabrication & erection of bagassecillo line, dismantling, fabrication & erection of underground & outside pipeline of all sizes, boiler/turbine, cooling tower sugar godown/workshop/store/cane unloader & factory, fab & erection of gate, strengthning of tress beams,vessel,pipe with channel,angle,pipe etc any where, roof sheets /acc /iron sheet work. dis-, roof sheets /acc /iron sheet work. repair, roof sheets /acc /iron sheet work. replacement & erection, fab & erection of m.s.stair/ladder a) single story , double story, dismantling, fabrication & erection of underground and outside pipeline of all sizes, fabrication & erection of nrv of ct pump, dismantling, fabrication & erection of cooling tower pipeline from cooling tower of turbine, dis. of old damaged platform from boiler to turbine, fabrication & erection of platform (size- 1mtr width) from boiler to turbine material of old esp, misc .items., m.s pipeline per inch dia//ft/length (a ) dismentling of pipe line., upto 1 dia to 12 dia ., above 12 , fabrication of pipe line from m.s.plate or ready-made pipe any dia ., erection of pipe line per inch dia/ft/length (i) upto 1 dia to, erection of pipe line per inch dia/ft/length (ii. above 12 dia, m.s.pipe accessories work, dismantling of bends, tee, reducder, cross, elbow,nipple,nozzle, flanged, and bends. (per inch dia/ft/length ) (a) upto 1 dia to 12 dia, m.s.pipe accessories work, dismantling of bends, tee, reducder, cross, elbow,nipple,nozzle, flanged, and bends. (per inch dia/ft/length (ii.) above 12 dia., fabrication of bends, tee, reducer etc.-(p.inch dia/ft) (i) upto 1 diato 12 dia, fabrication of bends, t
Tender For supply of spares of sunbeam make air conditioner for draglines c c - part no. pr77164 compressor , part no. pr36390 condenser coil , part no. pr79197 evaporator coil , part no. pr38163 solenoid valve , part no. pr37161 main supply mccb , part no. pr37192 mpcb for fresh air fan , part no. pr37188 mpcb for cond and evp fan , part no. pr35732 mpcb for compressor , part no. pr17808 add on block for contactor nc , part no. pr17809 add on block for contactor no , part no. pr37003 comp oil monitoring controller , part no. pr78353 evaporator fan , part no. pr38160 solenoid valve coil , part no. pr51058 orifice , part no. pr36426 drier , part no. pr36898 hp lp switch , part no. pr61793 fresh air fan , part no. pr61600 air cleaner assembly , part no. pr37172 pre cleaner assembly , part no. pr61792 cover assembly , part no. pr62027 temperature controller , part no. pr77531 contractor fans , part no. pr35728 contactor compressor , part no. pr37351 timer , part no. pr37559 auxillary relay , part no. pr38147 single phase preventor , part no. pr81512 fresh air primary filter , part no. pr80646 ntc sensor , part no. pr80143 capacity control sol. coil , part no. pr37698 control panel cooling fan ) /bid number : gem/2025/b/6495536 * /dated: 25-07-2025 & & / bid document 1 / 27
Tender For procurement of refrigeration and air conditioning lab equipment for mechanical engineering department. - refrigeration and air conditioning lab equipment, cooling tower test rigexperiment: to determine the efficency of forced draft type coolingtowercooling tower:250 x 250 mm size, height 1000 mm,material: aluminum body with acrylic framepacking sheets: perforated aluminum corrugatedblower : 1hpgeyaser: 3 kw capacityindicator: digital temperature indicator 8 channelthermocouples:1 mtr length, cr. al, wire mesh sheathingair flow measurement: u tube manometer, material glass, size 300mmwater flow measurement: rotameter 0 to 60 cc/seccalibrated water tank : ms, 200 x 250 mm sizestarter: crompton/any reputed make., vapour compression refrigeration test rig compressor type: hermetically shield600 wcooling capacity: 0.3trtechnology: inverter controlrefrigerant: r 600ano of passes: singletube material: copperenergy meter: 1 phase 230 vtemperature sensor: rtd (5 no s)storage space: 591*621*1500 mmcondenser: finned tube typeevaporator: plate typeexpansion valve: capillary coil type, open type air conditioning test rigtechnical specificationstype : single cylindercompressor : 1 tondischarge : 0-10 lphrefrigerant : r 122 or suitablecondenser details : air cooledevaporator : 10 litre capacityno of passes : singleouter tube dia : 6mmexpansion device : capillary tubepressure drop : 0.5 kgf / cm2tube material : copperfan (230 volts 2 amps) : one no (for condenser)freezer box : evaporator unit consists of a ss freezerenergy meter : single phase 230 voltstemp. measurement : 5 no s rtd sensor will be provided to measurethe temperature pointtemperature indicator: 8 channel digital temperature indicator with selector knob to change the temperature point.the whole set-up is ingeniously designed and schematically arranged on apowder-coated rigid structure, recirculating air conditioning test rigcapacity: 1.0 tr compressor: hermetically sealed. condenser: forced convection air cooled.condenser fan:axial flow.drier/ filter: provided.expansion device:capillary tube.evaporator:forced convection air cooled.evaporator fan: axial flow typerefrigerant:r-22.hp / lp cut-out:alco/ or danfoss / or indfoss or any equivalent make.temperature: 6 channel facilities with digital display.pressure:2 nos.; dial type pressure gauges.air flow measurement: by inclined tube manometersupply:220-240 volts, 50 hz, 1 phase.input power: provided for compressor and heater.list of experiments:cooling of fresh air with full exhaust. (summer experiment)heating of fresh air with full exhaust. (winter experiment)humidification of air.cooling or heating the air with partial recirculation.(calculations for mixing of two air streams having different characteristics.)cooling of air with full re-circulation (operation of the system as a window air conditioner.)