Get complete information related to latest Cooler Fan Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cooler Fan Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cooler Fan Tenders.
Tender For supply, delivery and fitting of 440volt, 3phase, 1440 rpm ,550 watt heavy duty tubular man coolerfan with allied works at intake (raw water) pumping station near durgapur barrage block borjora, dist bankura under bmd phe dte.
Tender For annual rate contract for carrying out the following jobs of ammonia-iii plant for one year: a. replacement/repairing& re-fitting of damaged support spring coils of primary reformer catalyst tubes. b. straightening of bend/deformed fins of the tubes of solution coolerfan c. opening, cleaning and box up of burners of primary reformer.
Tender For corrigendum : tender for supply of motor rewinding - rewinding of three phase , 415 v , 50hz motors upto 1.1kw as per annexure-1 , rewinding of three phase , 415 v , 50hz motors more than 1.1 kw to 2.2 kw.as per annexure-1 , rewinding of three phase , 415 v , 50hz motors more than 2.2 kw upto 5.5 kw.as per annexure-1 , rewinding of three phase , 415 v , 50hz motors more than 5.5 kw upto 11 kw.as per annexure-1 , rewinding of three phase , 415 v , 50hz motors more than 11kw upto 22kw.as per annexure-1 , rewinding of three phase , 415 v , 50hz motors more than 22kw upto 55kw as per annexure-1 , rewinding of three phase , 415 v , 50hz motors more than 55kw upto 75kw as per annexure-1 , rewinding of three phase , 415 v , 50hz motors more than 75kw upto 90kw as per annexure-1 , rewinding of three phase , 415 v , 50hz motors more than 90kw upto 110kw as per annexure-1 , rewinding of three phase , 415 v , 50hz motors more than 110kw upto 132kw as per annexure-1 , rewinding of single phase , 230 v , 50hz motors exhaust fan/pedestal fan/ wall mounted fan upto 400mm sweep as per annexure-1 , rewinding of single phase , 230 v , 50hz motors ceiling fan/ exhaust fan/coolerfan/ wall mounted fan above 400mm sweep as per annexure-1 , rewinding of single phase motors upto 1.1 kw.as per annexure-1 , rewinding of single phase control transformer upto 500 va as per annexure-1 , dynamic balancing of rotor with 2.5 microns accuracy (balancing grade is gr 2.5 as per iso 1940) more than 1 kg upto 4 kg as per annexure-1 , dynamic balancing of rotor with 2.5 microns accuracy (balancing grade is gr 2.5 as per iso 1940) more than 4 kg upto 16 kg as per annexure-1 , dynamic balancing of rotor with 2.5 microns accuracy (balancing grade is gr 2.5 as per iso 1940) more than 16 kg upto 48 kg as per annexure-1 , dynamic balancing of rotor with 2.5 microns accuracy (balancing grade is gr 2.5 as per iso 1940) more than 48 kg upto 96 kg as per annexure-1 , dynamic balancing of rotor with 2.5 microns accuracy (balancing grade is gr 2.5 as per iso 1940) more than 96 kg upto 192 kg as per annexure-1 , dynamic balancing of rotor with 2.5 microns accuracy (balancing grade is gr 2.5 as per iso 1940) more than 192 kg upto 378 kg as per annexure-1 , dynamic balancing of rotor with 2.5 microns accuracy (balancing grade is gr 2.5 as per iso 1940) more than 378 kg upto 500 kg as per annexure-1 , dynamic balancing of rotor with 2.5 microns accuracy (balancing grade is gr 2.5 as per iso 1940) more than 500 kg upto 1000 kg as per annexure-1 , dynamic balancing of rotor with 2.5 microns accuracy (balancing grade is gr 2.5 as per iso 1940) more than 1000 kg upto 1500 kg as per annexure-1 , dynamic balancing of rotor with 2.5 microns accuracy (balancing grade is gr 2.5 as per iso 1940) more than 1500 kg upto 3000 kg as per annexure-1 , remetalizing of shaft using tafa arc technique after preparation of surface and machining to proper size upto 1.5 kw as per annexure-1 , remetalizing of shaft using tafa arc technique after preparation of surface and machining to proper size more than 1.5 kw upto 7.5 kw as per annexure-1 , remetalizing of shaft using tafa arc technique after preparation of surface and machining to proper size more than 7.5 kw upto 15 kw as per annexure-1 , remetalizing of shaft using tafa arc technique after preparation of surface and machining to proper size more than 15 kw upto 45 kw as per annexure-1 , remetalizing of shaft using tafa arc technique after preparation of surface and machining to proper size more than 45 kw upto 90 kw as per annexure-1 , remetalizing of shaft using tafa arc technique after preparation of surface and machining to proper size more than 90 kw upto 170 kw as per annexure-1 , remetalizing of end covers using tafa arc technique after preparation of surface and machining to proper size upto 1.5 kw as per annexure-1 , remetalizing of end covers using tafa arc technique after preparation of surface and machining to proper size more than 1.
Tender For annual rate contract for carrying out the repairing and re-fitting of damaged support spring coils of pr catalyst tubes, straightening of deformed fins of the tubes of solution coolerfan and opening, cleaning and box up of burners of pr
Tender For corrigendum : providing of custom bid for services - rate contract for repair of various coolerfans installed in different transformers and reactors and pole 2 valve cooling system at powergrid vizag station