Web Analytics Made Easy - StatCounter

Cooling Tower Sale Tenders

Get complete information related to latest Cooling Tower Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cooling Tower Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cooling Tower Sale Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :39410677 Due date: 24 Feb, 202524 Feb, 2025 NA
Tender For regarding repair work of oil cooling system etc. of this plant through external agency under divisional office mechanical sub division plant at latur tata hitachi excavator-350 no. 402

CTN :39344699 Due date: 08 Mar, 202508 Mar, 2025 NA
Tender For supply of brake pad front change , brake shoe rear change , front caliper assy change , rear brake drum , ignition coil change , spark plug change , realy change , plug wire change , electronic injector repair , seat adjuster , horn assy change , steering assy , the above mentioned parts removing the veh and all reqires portion service and all new parts fitting, engine tuning electrical check and wheel alignment and balancing , rotary pump assy and feed pump removing the veh and taken to the pump house and stripping all parts and cleaning checking. injector nozzle , pump full service and assembles above mentioned burned and damaged change and full packing change nozzle fitting injector , feed pump service with kit vehcile overbeating and produce white smoke. engine required for overhauling , engine liner set change , piston change , main bearing change , bigend bearing change , thrust washer change , piston ring change , valve inlet and exhaust change , valve guide change , head gasket change , gasket kit change , crunk shaft seal change , water pump change , engine mounting pad change , oil filter change , air filter change , fuel filter change , fan belt change , timing belt change , timing tensoner change , clutch plate change , pressure plate change , release bearing change , fly wheel skimming change , fly wheel bearing change , hub seal inner and outlet change , annabond paste , radiator hose set change , front brake pad change , rear brake shoe change , suspension bush kit change , radiator repair and service , self and alternator repair and service. lathe machine works , engine bore boring and new liner fitting and boning and finishing and piston seting , crank shaft main and both bearing setting , cylinder head stripping, cleaning and old valve guide, removing and new guide fitting and valve seat, grinding, vlave fixing and head assy and pressure testing , engine assy removing the veh and stripping and cleaning all parts and engine assy and mounting the veh and self, alternator raditor fitting and veh started testing cooling labou charge , electrical system checking and wheel alignmnet and balancing , timing shain kit change , brake shoe front and change , chain sprocket kit change , kiker change , engine bore reboring, boning and finishing , the above mentioned all parts removing and new parts fitting labour charge , self starter ssy repair service with unservicable parts change, field coil, armature soldering and brush holder and brush change

CTN :39370217 Due date: 10 Mar, 202510 Mar, 2025 NA
Tender For repair of sprinkler system - repair of sprinkler system , repair of tower cooler , repair of duct cooling system , repair of desert cooler , whitener , pencil , highlighter

CTN :39335016 Due date: 24 Feb, 202524 Feb, 2025 NA
Tender For tender for supply of rewinding of 1 hp flp motor including cost of loading , unloading , transportation to the repairer site and getting back from repairer. , rewinding of 1 hp flp motor including cost of loading , unloading , transportation to the repairer site and getting back from repairer. , rewinding of 5 hp flp motor including cost of loading , unloading , transportation to the repairer site and getting back from repairer. , rewinding of 7.5 hp flp motor including cost of loading , unloading , transportation to the repairer site and getting back from repairer. , rewinding of 10 hp flp motor including cost of loading , unloading , transportation to the repairer site and getting back from repairer. , scope includes repairing of eld and gd transmitter used to detect the valve leak cylinders in chain conveyor system. , scope includes repairing of eld and gd receiver used to detect the valve leak cylinders in chain conveyor system , scope includes repairing of old and pt transmitter used to detect the o-ring leak cylinders. , scope includes repairing of cuc of carousel mark-ii & mark iv. , supply of outer o-ring for lot valves for 47.5 and 35 kg cylinders , supply of inner o-ring for lot valves for 47.5 and 35 kg cylinders , supply of caps for lot valves for 47.5 and 35 kg cylinders , repair work of defective repair work , repair of worm gear type gear box including cost of loading , unloading , transportation to the repairer site and getting back from repairer. scope will include replacement of sprockets , gaskets and seal kit. , scope includes machining of tail end shaft of length 380mm , outer dia 40mm as per instructions of lic or oic. , scope includes machining of shaft of outer dia 60mm as per instructions of lic or oic , scope includes machining of shaft of outer dia 65mm as per instructions of lic or oic. , repair of service water pump including cost of loading , unloading , transportation to the repairer site and getting back from repairer. scope will include replacement of gaskets , seal kit , impeller etc. or any other material required to successfully recommission the pump. , scope includes supply and replacement of die and servicing of hydraulic pump and replacement of oil etc. , scope includes supply and replacement of hydraulic seal kit and servicing of hydraulic pump and replacement of oil etc. , scope includes supply and replacement of hydraulic seal kit and servicing of hydraulic pump and replacement of oil et , scope includes supply and replacement of hydraulic seal kit and servicing of hydraulic pump and replacement of oil as well as rewinding of motor etc. , repair of cooling water pump including cost of loading , unloading , transportation to the repairer site and getting back from repairer. scope will include replacement of gaskets , seal kit , impeller etc. or any other material required to successfully recommission the pump. , repair of washing water pump including cost of loading , unloading , transportation to the repairer site and getting back from repairer. scope will include replacement of gaskets , seal kit , impeller etc. or any other material required to successfully recommission the pump , this includes servicing of tt gantry arms and replacement of spares part in loading and unloading arms , charges for providing services for shifting of 14.2 kg cylinders from ground to shed. , charges for providing services for shifting of 14.2 kg cylinders from shed to ground , charges for providing services for shifting of 19 kg cylinders from ground to shed. , charges for providing services for shifting of 19 kg cylinders from shed to ground. , charges for providing services for shifting of 5 kg cylinders from ground to shed. , charges for providing services for shifting of 5 kg cylinders from shed to ground. , charges for unloading of conkote drums from vehicle to ground and stacking the same. , charges for unloading of sc caps from vehicle to ground and stacking the same , charges for unloading of

CTN :39319672 Due date: 07 Mar, 202507 Mar, 2025 NA
Tender For repair veh no 12c 092519m tata telcoline - servicing and repairing of air cooling system , ac compressor , ac evaporaor coil , realy 12 v , ac compressor oil 150 ml , ac condensor , rc134 cfc gas600gm , repairing overhauling , blance rod , suspension bush , pilot bush , bolzen , drive shaft , oil seal , front shocker , link rod

Central Government/Public Sector

CTN :39065250 Due date: 20 Feb, 202520 Feb, 2025 NA
Tender For corrigendum : special repair replacement of lt network street light system at fd hosp, special repair replacement of ber cooling appliances and provn of lt panel alongwith connected items for power supply at sugnu ground at dipatoli under ge dipatoli

CTN :39255125 Due date: 28 Feb, 202528 Feb, 2025 NA
Tender For supply of self field coild change - self armature change , self field coil change , brush carried change , solenoid switch change , bush self change , self repair and service charge , propeller shaft universal joint , clutch plate change , pressure plate change , release bearing , timing belt , timing tensioner , suspension bash kit , rear right side bearing , clutch cable , accelerator cale , speedo meter cable , ignition coil , the gear box assembly removed plate, release, old clutch plate,and veh engine tuning and vehicle testing labour charges , field coil shert change , solenoid burned change , armature short and damaged change , bushes change , self repair service, change the parts labour charges , ht lead change , fly wheel bearing change , release bearing change , spark plug change , hub oil seal inner and outer change , axial tube oil seal change , engine liner set change , connecting bearing change , engine main bearing change , thrust warber change , valve set change , valve guide change , head gasket change , oil seal kit change , water pump change , engine mounting pad , oil filter change , air filter change , fuel filter change , annabond paste , radiator house set change , fan belt change , timing belt change , radiator repair service and soldering , alternator repair and service , full engine removing stripping service, and engine assembling and mounting the veh and engine starting, running, cooling and setting , brake lining change , brake booster repair , dual brake valve change , self starter repair and service , brake drum skimming , vehicle gear box assembly dismantling the vehicle and release bearing fitting, gear box mounting the vehicle and gear testing , brake shoe, brake booster, clutch booster removing the vehicle after repair fitting the vehicle labour , vehicle electrical system full checking and burning looms, vehicle electrical system service and vehicle testing , rotary pump removing the vehicle and taken to the pump house and stripping checking all parts. all parts cleaning , pump full service and burned parts and oils seals, calibrating with computerised machine

CTN :39195935 Due date: 24 Feb, 202524 Feb, 2025 NA
Tender For supply of road spring broken , electrical system not working full relay socket, fuse box, and full wiring checking and change the burning looms. , self starter not working, self starter assembly repair and service all burning and damaged parts change , turbo charger stud broken and silencer pipe broken , turbo charger broken silencer pipe removing the vehicle and taken to the welding shop broken portion cutting and new welding finishing , both side wiper blade change , wheel alignment and balancing , break system full service , cooling system repair and service , vehicle full service, engine oil, oil filter, fuel filter, air filter change and vehicle full service, water washing, wheel alignment and balancing. , front road spring new fitting , tapet cover seal new fitted , engine head gasket , steering gear box over haulding , radiator cap , main bearing oil seal , the above mention parts removing, cleaning and new parts fitting

Central Government/Public Sector

CTN :39145973 Due date: 20 Feb, 202520 Feb, 2025 NA
Tender For custom bid for services - comprehensive annual maintenance contract of cs12 eakon cold store located at doddanekundi plant acd for a period of 3 years -summary: comprehensive annual maintenance contract includes maintenance, repair/replacement of all the components of the cold stores as follows: a) compressor, condenser unit, evaporator unit, suitable refrigerant, power supply system, control system, all safety features, operator panel, different type of sensors, interconnecting piping including drainage water pipes, cold room panels, coil and drain heaters, doors, lighting, temperature recording panels, and all other electrical, mechanical as well as electronics components of the systems & eurotherm electronic recorder.b) detailed scope of work:1 vendor should take over the cold stores for camc, in as-is-conditions., 2) preventive maintenance (pm) of the units to be carried out every month in consultation with user / maintenance dept, and detailed pm schedule to be drawn up and a copy of the pm carried out (service report) should be forwarded to purchase department duly endorsed by maintenance dept. for the reference and records. this pm should be carried out apart from periodical servicing and attending the breakdown calls. 3) servicing of the units should be carried out once in every three months, within two weeks of commencement of the quarter. this should be carried out preferably on sundays/ holidays. this servicing involves cleaning of condensers, cooling coils, filters (if any) leakage testing & rectification; and any/all other works required to ensure proper functioning of the units. a copy of the service carried out (service report) should be forwarded to purchase dept. duly endorsed by user/ maintenance dept for the reference and records. 4) the firm should monitor the temperature/ attend breakdown / preventive maintenance or any other request from user/ maintenance /quality dept. & monitor the functioning of all the cold stores. the firm should monitor and record the cold store chamber temperature every hour during shift hours and should take signature on recorded values by user, quality dept /maintenance dept. daily. the camc vendor s scope of work will be active for three shifts per day/round the clock, including sundays & holidays, i.e. all days throughout the camc period. 5) the firm should inform all the three departments user/qa/maint. in the event of malfunctioning of the equipment is noticed. they also should ensure safety of the materials stored in the event of failure of the cold stores. 6) the firm should report any abnormality, breakdown, or any bypass made immediately to all the three dept viz user, maintenance and quality dept. the equipment uptime should be greater than 95% without any interruption. 7) the firm should inform to the maintenance department in the case power failure, so that maintenance dept. can arrange for switching on the dg supply. 8) the firm should able to read the temperature in the electronic temperature recorder. 9) the firm should attend any number of breakdown complaints as and when reported by user/ maintenance dept/ quality dept during the contract period. the breakdown complaints should be attended within 8 hrs from the receipt of oral or written complaints and the system should be rectified within a day, except for the major breakdowns. 10) the firm should bring all the tools and tackles necessary including consumables for the repair / servicing. 11) the firm should hand over the cold stores in good working condition after the completion of camc, failing which necessary remedial actions will be taken to recover loses to acd-hal by deducting equivalent amount from the due amount. c) monthly checks: checking and servicing of cold stores.- (a) compressors- condensing units, solenoid valves and all gauges, drier, globe valves and all gauges, hp/lp switches, oil pressure switches ., expansion valve and mixture., refrigerant level and top-up if required., oil le
 Loading, Please wait...

Connect us via What's Up