Get complete information related to latest Cooling Unit Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cooling Unit Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cooling Unit Scrap Tenders.
Tender For hydraulic pressure testing and refilling of old fire extinguisher along with supply, installation of new afff type fire extinguisher, fire extinguisher, accessories and safety poster at sharda power house, lohiahead 2.annual maintenance of tube wells, pipe lines, cooling water pumps & cleaning of underground cooling water filtration tank along with cleaning of grass, bushes, rubbish etc near cooling water pump house, shaft seal tank area, emulsifier pump house area & premises at sharda power house lohiahead. 3.in situ machining of collector ring of the excitation system of unit 1, 2 & 3 at sharda power house, lohiahead. 4.repair of borewell pump-motor set, ceiling fans, exhaust fans of 40 mva transformers, 20 mva transformers, turbine hall and battery room at sharda power house, lohiahead on open tender basis
Tender For purchase of mini lorry for public health use in p.n.patty town panchayat - a hopper tipper dumper is a truck designed for carryingmaterial, which may be garbage, construction material,mining minerals and any other loose material. the truck isfi tted with specially designed hydraulic tipping mechanismdriven by pto or power pack, which enables the dumper(rear portion expect the driver cage) to move up and downfor unloading of the material. it is the safest way to quicklytransport loose materials from one site to another., generic parametersvehicle category, generic parametersvehicle category, vehicle engine cubic capacity (cc), type of fuel, vehicle emission compliance, number of cylinder in engine (nos), vehicle mileage (declared by oem as certified by test agencyunder rule 115 of cmvr 1989) (kmpl), gradeability of vehicle (degree in first gear), maximum engine power range (in kw), max engine power (kw@rpm), max engine torque (nm@rpm), fuel tank capacity (liter), category of vehicle for which chassis to be used, overall length of vehicle (mm), overall width of vehicle (mm), overall height of vehicle (mm), ground clearance (mm), minimum wheel base (mm), type of tyre and tube (for both front and rear), front vehicle brake, rear vehicle brake, vehicle transmission system, type of steering, turning radius (mm), nos of forward gears, vehicle air intake system, type of clutch, axle configuration, front axle suspension system, rear axle suspension system, air conditioning, standard spare wheel and tool kit, warranty period, battery warranty (month), number of free service (nos), fabrication description, type of tipper, define type of tipper, tipping angle (degree), hopper tipper dumper container capacity/volume (cubicmetres), tipper body pivot length (mm), tipper body length (mm), tipper body height (mm), overall height of tipper from ground (mm), dumping height (mm), body plate thickness (mm), tipper sub frame thickness (mm), hydraulic system, tipping hydraulic cylinders(make), hydraulic system driven by, tipper container material, engine oil pressure level indicator in control panel, fuel gauge indicator in control panel, engine cooling liquid temperature indicator in control panel, operating hour meter, locking/unlocking of tipper discharge container, lowering/lifting of tipper discharge container, counter weight, insurance charges, temporary registration charges & permanent registration charges
Tender For provn of generator spares - coolant for genr set 15 kva make kirloskar , engine oil for genr set 15 kva make kirloskar , cable 25 sq mm 2 core for genr set 15 kva make kirloskar , stabilizer for genr set 15 kva make kirloskar , over flow pipe for genr set 15 kva make kirloskar , piston assy for genr set 15 kva make kirloskar , piston ring set for genr set 15 kva make kirloskar , cylinder liner for genr set 15 kva make kirloskar , head gasket for genr set 15 kva make kirloskar , tappet cover gasket for genr set 15 kva make kirloskar , inlet manifold gasket for genr set 15 kva make kirloskar , exhaust manifold gasket for genr set 15 kva make kirloskar , cooling fan for genr set 15 kva make kirloskar , fuel filter for genr set 15 kva make kirloskar , oil filter for genr set 15 kva make kirloskar , air cleaner for genr set 15 kva make kirloskar , cable 25 sq mm 4 core for genr set 30 kva make kirloskar , cable 50 sq mm 4 core for genr set 30 kva make kirloskar , bty 12 v 110 ahc for genr set 30 kva make kirloskar , injector nozzle assy for genr set 30 kva make kirloskar , piston assy for genr set 30 kva make kirloskar , piston ring set for genr set 30 kva make kirloskar , gudgeon pin for genr set 30 kva make kirloskar , big end bearing set for genr set 30 kva make kirloskar , cylinder liner for genr set 30 kva make kirloskar , push rod for genr set 30 kva make kirloskar , push rod tube rubber gasket for genr set 30 kva make kirloskar , cyl head gasket for genr set 30 kva make kirloskar , tappet cover gasket for genr set 30 kva make kirloskar , inlet manifold gasket for genr set 30 kva make kirloskar , exhaust manifold gasket for genr set 30 kva make kirloskar , oil pump assy for genr set 30 kva make kirloskar , air cleaner for genr set 30 kva make kirloskar , fuel filter for genr set 30 kva make kirloskar , oil filter for genr set 30 kva make kirloskar , water pump assy for genr set 30 kva make kirloskar , cooling fan for genr set 30 kva make kirloskar , fan belt for genr set 30 kva make kirloskar , fuel pipe 19 nos for genr set 30 kva make kirloskar , injector overflow pipe for genr set 30 kva make kirloskar , banzo bolt 19 nos for genr set 30 kva make kirloskar , copper washer 17 and 19 nos for genr set 30 kva make kirloskar , engine oil for genr set 30 kva make kirloskar , coolant for genr set 30 kva make kirloskar , avr assy for genr set 30 kva make kirloskar , hours meter for genr set 30 kva make kirloskar , oil pressure gauge for genr set 30 kva make kirloskar , crank shaft cutting for genr set 30 kva make kirloskar , cylinder head leaking check for genr set 30 kva make kirloskar , armature winding short reqd necessary repair of the eqpt for gen set 15 kva make kirloskar , fuel pump for gen set 5 kva make koel , sim for gen set 5 kva make koel , injector for gen set 5 kva make koel , fuel filter for gen set 5 kva make koel , air cleaner for gen set 5 kva make koel
Tender For corrigendum : supply of packaged air conditioners - supply of air cooled floor mounted package air conditioner having cooling capacity q -48 kw min air flow rate 11000 cmh min and pressure head 400 pa min as per attached technical specification , supply of air cooled floor mounted package air conditioner having cooling capacity q-24.3 kw min air flow rate 4080 cmh min as per attached technical specification , supply of air cooled floor mounted package air conditioner having cooling capacity q-32 kw min air flow rate 7000 cmh min and pressure head 600 pa min as per attached technical specification , supply of air cooled floor mounted package air conditioner having cooling capacity q- 10.92 kw min air flow rate 6300 cmh min and pressure head 600 pa min as per attached technical specification , supply of air cooled floor mounted package air conditioner having cooling capacity q-16 kw min air flow rate 4000 cmh min and pressure head 400 pa min as per attached technical specification , supply of air cooled floor mounted package air conditioner having cooling capacity q-45 kw min air flow rate 9000 cmh min and pressure head 500 pa min as per attached technical specification , supply of ceiling mounted ductable idu unit of cooling capacity 3 tr air cooled including additional 5 meter copper tube length liquid , supply of split system with suspended sub ceiling idu of cooling capacity 4 tr min air cooled odu unit including additional 5 meter copper tube length liquid
Tender For supply installation testing and commissioning of wall mounted split and ceiling mounted cassette ac - supply of 1.5 t inverter single phase ceiling mounted cassette ac having outdoor unitcooling capacity more than 5000w and input power -1600w. indoor unitcooling capacity more than 5000w refregerenat-r-32 or r-410 as required , noise level less than 50db , 03 star make-bluestar , daikin , carrier , lloyed , voltas , supply of 1.5 tonn single phase wall mounted split ac at u s complex building new delhi. having outdoor unitcooling capacity more than 5000 watts and input power more than 1600 watts. indoor unitcooling capacity more than 5000 wattas refregerenat-r-32 or r-410 as required noise level less than 50db three star make-blue star , daikin , carrier , lloyed , voltas , , installation charges of 1.5 tonn inveter type single phase ceiling mounted cassette a c at u s complex building new delhi. make-blue star , daikin , carrier , lloyed , voltas , , installation charges of 1.5 tonn single phase wall mounted split ac at u s complex building new delhi make-blue star , daikin , carrier , lloyed , voltas , , supply and fixing of pvc drain pipe including elbow , bends , sockets , insulation etc. , supply and laying of 4x2.5 sq mm pvc insulated flexible cable for connection of indoor and outdoor unit , refregerent (r-32/r-410)gas as required for charging for all split & cassette ac , supply & fixing of floor mounting pre fabicated powder coated m s stand for split & cassette ac suitable to out door units , schedule-b buy back value of existing acs) buy back value of 1.5 tonn non-inveter type single phase ceiling mounted cassette a c at u s complex building new delhi. having outdoor unitcooling capacity more than 5000 watts & input power -1600 watts. indoor unitcooling capacity more than 5000 wattas refregerenat-r-32 or r-22 as required noise level less than 50db three star make-blue star(9 nos) , daikin , , schedule-b buy back value of existing acs) , buy back value of 1.5 tonn non-inveter type single phase wall mounted split ac at u s complex building new delhi. having outdoor unitcooling capacity more than 5000 watts and input power more than 1600 watts. indoor unitcooling capacity more than 5000 wattas refregerenat-r-32 or r-22 as required noise level less than 50db three star make-daikin(3 nos) (1 nos) lg. , schedule c -dsr-2019 (vrv or vrf air conditioning systems 2019) 6.4 mm dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation , schedule c -dsr-2019 (vrv/vrf air conditioning systems 2019) 12.7 mm dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation , schedule c -dsr-2019 (vrv/vrf air conditioning systems 2019) 19 mm dia (od) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation