Tender For tender for work of conversion dog to panther of 66kv s/c jangral(220kv s/s) to jangral(66kv s/s) line-1 on d/c panther tower with acsr panther conductor under deesa tr div, palanpur tr circle under r&m plan 2025-26
Tender For corrigendum : tender for replacement of dog conductor by panther conductor of 66kv kansari ramun line under dhanera division under palanpur circle.(buy back)
Tender For supply erection testing & commission of dog to panther conversion of existing 66 kv s/c vav deladva line by panther tower with s/c acsr panther conductor stringing
Tender For custom bid for services - the diversion of the 1 kilometer 3 3 overhead power line at dhoptala ocm of sasti sub area-1 "erecting rolled steei joist (girder) pole 200 * 100 mm. (25, 0kg / m) with provided base plate in provided foundation as per specification no. , ", 2 making cement concrete foundation including excavation (60 * 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 * 25mm stone metal, 45 cm x 45 cm x 45 cm 145 cm dia. x 45 cm. height plinth duly plastered, with necessary joating ang hoisting complete. (tor upto 9 m poles) , 3 "supplying and erecting g.l. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 * 6 mm., straining screws. g.l. stay wire 7/8 swg.g.i. stay rod 20 mm x 1.8m length and pole clamps duly erected in provided cement concrete foundation., ", 4 "making cement concrete foundation including excavation ( 60 * 60 * 150) cim deep in 1:3:6 cement concrete, (20 to 25) min stone with necessary curing and finishing complete. (for stay). , ", 5 ereeting acsr conductor of size-6/1-4.72 mm (dog) complete. (394 kg(km) as per specification no oicon/acsr, 6 "supplying and erecting v cross arm with ism channel of, 75x40x6mm for 11kv ht oil line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of v cross arm as 460mm, and fixed on pole with ms clamp of 80x10 mm, nut bolts, washers complete as per specification no.oh-pl/vcaerecting acsr conductor of size-6/1-4.72 mm (dog) complete. (394 kg/km) as per specification no. ohcon/acsr", 7 supplying and erecting porcelaindise type insulator 45knwith necessary hardware suitable for ikv line, complete as pe specification no. , 8 supplying and erecting porcelain pin type insulator with g.l. pin suitable for 11kv line, complete as per specification no., 9 "supplying, installing and testing pipe type earthing with 40mm. dia. g.i. pipe or 20 mm dia. g.1. rod complete with all accessories of gl materials & recording the results as per specification no. , ", 10 paintingofsteeltubular/rail/rsjpoleabove6.0mlengthalongwith street light polebrackets, clamps etcby scrapping the existingpaint complete asper specification no., 11 supplying and erecting anti climbing devices, fabricated from pole clamps of ms flat 40x5 mm, with drooping spikes 15 cm, in length, welded to it and erected on pole complete.
Tender For corrigendum : daivya apda work under edd fatehabad - carriage of following from 132 kv taj agra to 33/11 kv substations through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-70kms.) 8.5/9/11 mtr/13mtr.. long pcc/stp poles., carriage of following from 132 kv taj agra to 33/11 kv substations through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-70 kms.) 11 kv x-arms, weasal conductor, g.i wire,disc insulators, pin insulators, clamps and other required line material, if any., carriage of following from realted 33/11 kv substations to site of work i.e. pit point through the kacha and pakka road by using manual labour or tractor/hydra as per site requirment including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-10 kms.) a) 8.5/9/11 mtr/13mtr.. long pcc/stp poles., carriage of following from realted 33/11 kv substations to site of work i.e. pit point through the kacha and pakka road by using manual labour or tractor/hydra as per site requirment including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-10 kms.)d) 11 kv x-arms, weasal conductor, g.i wire,disc insulators, pin insulators, clamps and other required line material, if any., cutting of kharanja/mettalic road/concrete portion while digging pit for erection of pcc/stp poles, stays rod and giving the exact shape after exicution work as per direction of supervising engineer. it includes the cost of labour, t & p, carrier etc reauired for proper completion of work., replacement & erection of damaged poles of lt lines by digging of pits and dismantling of all 11kv/lt accessories from the existing / damaged pole and erection of single new pole including fitting all accessories., replacement of damaged poles ht lines by digging of pits and dismantling of all 11kvkv accessories from the existing / damaged pole and erection of single new pole including fitting of all accessories., replacement of damaged poles 33 kv lines by digging of pits and dismantling of all 11kv/33 kv accessories from the existing / damaged pole and erection of single new pole including fitting of all accessories., grauting of new erected 8.5 mtr/ 9 mtr/11mtr/13mtr long pcc/stp poles, recostructions of damaged double pole (saction) on 11 kv lines by dismantling of t/f, opening of all accessories of lt s/s then removing damaged poles by digging earth pit(s), erecting new poles then fixing of of lt s/s accessories such as dropper channel, t/f base, disc insulators with fitting and other 11 kv accessories etc., required for proper completion of work., replacement of damaged double pole structure on 33 kv lines dismantling of t/f, opening of all accessories of lt s/s then removing damaged poles by digging earth pit(s), erecting new poles then fixing of of lt s/s accessories such as dropper channel, t/f base, disc insulators with fitting and other 11/33 kv accessories etc., required for proper completion of work., erection of stays its tightning, binding, nozelling etc. of stay wire with stay and stay clamp of pole as per requirement of work at site., re- sagging and stringing of existing conductor in 11kv/ /lt line as per direction of supervising engineer including the cost of arrangement of labour,t&p, carrier etc. required for proper completion of work a) acsr weasel conductor., b)acsr dog conductor., c) 50/95/120 sqmm abc., removal of following damaged conductor of existing damaged line including opeing of jumpers and line accessories etc making bundle, stacking at safe place and its relaying after completion of pole work, including fixing of acce
Tender For supply of spares/ stores/t&p/equipments/hardware items required from time to time for day to day operation/ maintenance/construction of power sub-transmission network of this division during the financial year 2025-26 or till the next rate contract - disc insulator 70kn b&s type, anti fog (reputed make/ already use in pdd), 33kv single tension disc fittings [3 bolts] suitable for dog conductor suitable for b&s 70kn disc insulators, 33kv pin insulators (porcelain) 70kn, 33kv g.i. pins (heavy duty), 11kv, 3 core cable kits [heat & shrinkable], a. indoor type, i) 600 mm. sq.single core, i. 400 mm sq., ii. 300 mm sq., iii. 240 mm sq, iv. 185 mm sq, b. outdoor type, i) 600 mm. sq.single core, i. 400 mm sq, ii. 300 mm sq, iii. 240 mm sq, iv. 185 mm sq, 11kv link set [heavy duty] 50*6 mm ( clamping suitable for dog conductor), 11kv l.a [station type]reputed make, 11kv l.a [line type] reputed make, guy wire 7/3.15mm, 33kv guy insulators, manila rope, i) 3/4 inch dia, ii) 1 inch dia, p.p.rope 3/4 dia, m.s. nut & bolts of sizes, i. 3" (full thread), ii. 6" (half thread), iii. 9" (half thread), iv. 10" (half thread), nuts and bolts brass, cork sheet 8mm, aluminum thimbles of sizes, i. 400mm sq, ii. 300mm sq, iii. 240mm sq, iv. 185mm sq, v. 120mm sq, drill bit [heavy duty], i. 16mm dia, ii. 19mm dia, iii.26mm dia, p.g clamps, i) suitable for panther conductor, ii) suitable for dog conductor, p.i clamps [suitable for dog conductor/panther], t clamps [suitable for dog conductor,panther ], brass bush rods of 33/11kv power transformer of sizes, i. hv [m20], ii. lv [m20], 33kv porcelain bushes of 33/11kv power transformer of sizes, i. hv side, ii. lv side, 3 core 11kv xlpe cable, i) 600 mm. sq., i. 400mm sq, ii. 300mm sq, iii. 240mm sq, iv. 185mm sq, v. 120mm sq, copper strip 20x3mm, vacuum interrupter suitable for, i. 11kv (yamuna] breaker, ii. 11kv [pascal] breaker, iii. 11kv (stelmec] breaker, iv. 11kv [schneider] breaker, iv. 11kv [electrifield make]breaker, aluminum bus bar 75x10mm, duck back shoes of different sizes, red oxide enamel paint (asian, nerolac/ berger), al. paint (asian, nerolac/ berger), 1.1kv voltage grade 2.5mm2 copperconductor, pvc insulated control cable conforming to is: 1554-1998, i. 2 core, ii. 4 core, iii. 5 core, iv) 8 core, iv. 10 core, v) 12core, 33kv current transformer of ratio, i. 750/375/5-5-5a, ii. 600/300/5-5-5a, iii. 400/200/5-5-5a, 33kv lightning arrestor [station type] reputed make, 33kv isolators with earthing blade, insulating hand gloves make crystal etc tested for 33kv level, aluminum ladder 9mtr long (folding), bamboo ladder 20 ft long, rubber mat 1mtr x2mtr, 12mm thick, 11kv operating rods, galvanised nuts and bolts of sorts, g.i wire 8 swg, lifting pulling machine 3 ton (make power ,wolf or any standard make), g.i earthing plates 2x2x6mm, pliers (taparia or any standard make), safety vest, safety belt, safety helmet (isi marked), 33kv danger plates complete, multimeter ( standard company make motwane , waco, etc), digital ampere meter [0-200/400 amps.], male contact (crompton greaves & emi make panel), female contact (crompton greaves & eim make panel), tripping coil suitable for 30/36v dc along with plunger for allind, bieco, make breaker, relays digital for vcbs for allind, bieco, easun,electricfield make panel, earth fault relay for vcb/ocb crompton greaves & emi make panel, over current relay for crompton greaves & emi make panel, 11kv ct set for breakers, i) 400-200/5 - 5amp, ii) 600-300/5 - 5amp, iii) 750-375/5 - 5amp, welding electrodes swg 8no as per is: 814 of 2004, maintenance free battery banks 36v ,vrla bank comprising of 18nos of cell [2 volt.100ah cell each] with tray and trolley of hbl,exide or any other reputed make, battery cells 2 volt,100ah(wet cell ) exide make, battery cells 2 volt,100ah (dry cell) exide make, master trip relay b24,110/125 v dc, guy rod complete with turn buckle, straining screws, guy plate etc [20mm] for 33 kv lines, transf
Tender For corrigendum : supply of hg fuses for 11kv and 33kv ht system - 12kv, 25a, 1-phase horn gap fuse as per enclosed technical specifications along with terminal connectors suitable for rabbit conductor for hyderabad ss , 12kv, 25a, 1-phase horn gap fuse as per enclosed technical specifications along with terminal connectors suitable for rabbit conductor for nagarjunasagar ss , 12kv, 25a, 1-phase horn gap fuse as per enclosed technical specifications along with terminal connectors suitable for rabbit conductor for kadapa ss , 12kv, 25a, 1-phase horn gap fuse as per enclosed technical specifications along with terminal connectors suitable for rabbit conductor for kadapa substation , 36kv, 25a, 1-phase horn gap fuse as per enclosed technical specifications along with terminal connectors suitable for dog conductor for khammam ss
Tender For bid to ras corrigendum : supply of electrical items - 1.5 sq mm isi marked frls pvc insulated single core copperconductorcable , 2.5 sq mm isi marked frls pvc insulated single core copperconductorcable , 6 sq mm isi marked frls pvc insulated single core copperconductorcable , flexible pipe 25 mm , flexible pipe 16 mm , pvc tape , pvc gully 6.5 mm , patta screw 1 inch , sp 5 by 6 a one way modular switch isi marked , 3 pin, 5 by 6 a modular socket outlet isi marked , modular pvc box for 12 module , modular base and cover plate for 12 module , modular ac box with mcb c 25 and plug top , horizontal type 3 pole neutral sheet steel mcb distribution board 415v on surface recess complete wid tinned copper, neutral,earth bus bar din bar interconnections powder paint including earthing , pvc clip 25 mm , pvc clip 16 mm , 25 mm dia isi marked pvc conduit , sp mcb c25a and c32a , 4 pole mccb 100a 30 ka , led tube light 18 or 20 w , 400 mm wall mounted fan , power combined board 5x15 a