Get complete information related to latest Copper Fuse Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Copper Fuse Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Copper Fuse Wire Tenders.
Tender For group a -rate contract for design, supply, installation, testing and commissioning of it hardware and rtus at cgd stations for a period of 3 years and annual rate contract for additional configuration/ modification/ diagnosis/ rectification works at site for rtu pane - rate of gst applicable for all items of the boq considering job as composite services. bidder to select one gst rate from the drop down list, supply, rtus, "type-1a rtu for cgs stations c/w processor module, i/o modules, redundant min 4 port l2 ethernet switches, relay modules, power sup plies, dual redundant field interrogation power supply & dc-dc/ ac-dc converters, data panel, communication ports, serial & ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, rtu cabinet etc. complete in all respect s as per i/o list & tender specifications etc. ", "type-2 rtu for cng ro stations & lng hubs c/w processor module, i/o modules, relay modules, power supply, dual redundant field inte rrogation power supply & dc-dc/ ac-dc converters, communication ports, serial & ethernet interfaces, necessary operating & applicati on s/w, all interconnecting cables, connectors, rtu cabinet etc. complete in all respects as per i/o list & tender specifications et c. ", "type-3 rtu for goov/gav / drs /mrs stations c/w processor module, i/o modules, relay modules, power supplies, dual redundant field interrogation power supply & dc-dc/ ac-dc converters, communication ports, serial interfaces, necessary operating & application s/w, all interconnecting cables, connectors, rtu cabinet in form of flp jb , suitable for hazardous area installation etc. complete in all respects as per i/o list & tender specifications etc. ", type-4 rtu for cgd control rooms for interfacing of all the rtus under ga with the supplied rtu as master c/w processor module, i/o modules, redundant min 6 port l2 ethernet switches, power supplies, data panel, dc-dc/ ac-dc converters communication ports, seria l & ethernet interfaces, necessary operating & application s/w, all interconnecting cables, connectors, rtu cabinet/ kiosk etc. comp lete in all respects as per i/o list & tender specifications etc., zener barriers, for ai, for ao, for pulse, surge protection devices, for rs 232/485 signals, 1 phase 2 wire (230 v/48vdc) applications, modbus gateway, industrial grade ethernet to 4 port serial gateway/ modbus tcp to modbus rtu converter with required connectors, cables, power suppl y etc. as per tender specifications, software, programming / ladder logic / testing software for rtus programming including one time license fee as per tender specifications.. (1 set= 1 programming/ladder logic/ testing software per site), hmi programming & runtime software of the hmi on the data panel as per tender specifications., it hardware, hmi machines as per tender specifications , along with accessories and softwares as per scope of work and technical specifications., supply of 23" display monitor as per tender specifications., industrial grade programming terminal (laptop) for bv-rtus: 10/100/1000 mbps ethernet card, rain, spill, dust and vibration resistan t, li-ion battery, power adapter, necessary interfaces (serial & parallel), necessary operating & application s/w, diagnostic s/w, s /w for operating rtu, carrying case complete with all interconnecting cables, cords, connectors, usb to serial (rs485) converter & p eripherals etc. complete in all respects as per tender specifications., wan router (8 port) system with software, cables, connectors etc complete in all respects as per tender specifications (plnet router ), firewall (type-ii) for control system to ensure control system security as per tender specifications complete with cables, connector s, software etc.as per specifications, 3g/4g/gsm routers for rtus for communication of the rtus over gprs/3g/4g in case of failure of the ofc communication sys
Tender For corrigendum : supply of naval store item for icgs 413 - circular stopper plate completeb2,b35 , dc patrol bag , foam liquid afff 20 ltr plastic container , antiflash hood , plug sq tappered soft wood , coulking shipwrights common , flax canvas variety no point 1 , anti flash gloves , splinter box size 160x160x127 mm , wire rope steel galavnsied for seizing 2 point 57 mm , wooden mallet medium , wedge hard wood , wedge soft wood 250mmx90mmx50mm thick , timber shore soft wood him season 100x100x300mm , stape steel clamp round 150 mm , sheet rubber typea, grade1 thickness 3mm, size 1mx1m , tapes measuring 15 mtrs , file 300mm bastared rough flat with 25 mm with handle , flat cold chisel 22x200h , battery dry 1 point 5 v size medium r14 , engineers screw driver 1 point 6x10x200 mm pr , oakum white , nail 63 mm chequred head , firmer chisel short plan 50 mm , tape insulation 25 mm steel grip isi mark , pyrotech light stick 8 inch , nail double point spiked head , ear seal for protector , wedges hard wood 150x75x25 mm , wedged hard wood 250x150x40 mm , arm badges
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For tender for supply of attending ea set located upto 25km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 25km to 50km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 50km to 100km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 100km to 200km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , carry out b check servicing of 7.5kva to 15kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 15kva to 32.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 32.5kva to 62.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool n tackle etc as reqd , carry out b check servicing of above 62.5kva to 125kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 160 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 200 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 250 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , providing and fixing of 12mm dia wire braided pvc pipe for diesel supply and return lines in existing ea set incl. testing , commissioning etc as reqd , providing and fixing of benjo and benjo bolt with washer and scew on pipe clamps at both ends for existing ea set incl. testing , commissioning etc as reqd , providing and topping up of corrosion inhibitor coolant in radiator of existing ea set incl. testing , commissioning etc. as reqd. , providing and topping up of 15w40 grade lubricating oil of recommended make in existing ea set incl. testing , commissioning etc. as reqd. , providing and fixing of 2 no. 50 sqmm copper conductor flexible cable leads each of 1 mtr length incl. lugs and battery terminals at both ends for starting battery of existing ea set as reqd. , providing and fixing of battery terminal socket set for dg starting battery incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve suitable for 7.5 kva to 32.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kva to 125 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 7.5 kva to 62.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 75 kva to 250 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of ignition switch or push button for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of engine start key switch incl. testing , commissioning etc. as reqd. , providing and fixing of oil pressure guage for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of water temperature guage for ea set incl. testin
Tender For tender for supply of attending ea set located upto 25km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 25km to 50km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 50km to 100km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 100km to 200km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , carry out b check servicing of 7.5kva to 15kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 15kva to 32.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 32.5kva to 62.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool n tackle etc as reqd , carry out b check servicing of above 62.5kva to 125kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 160 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 200 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 250 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , providing and fixing of 12mm dia wire braided pvc pipe for diesel supply and return lines in existing ea set incl. testing , commissioning etc as reqd , providing and fixing of benjo and benjo bolt with washer and scew on pipe clamps at both ends for existing ea set incl. testing , commissioning etc as reqd , providing and topping up of corrosion inhibitor coolant in radiator of existing ea set incl. testing , commissioning etc. as reqd. , providing and topping up of 15w40 grade lubricating oil of recommended make in existing ea set incl. testing , commissioning etc. as reqd. , providing and fixing of 2 no. 50 sqmm copper conductor flexible cable leads each of 1 mtr length incl. lugs and battery terminals at both ends for starting battery of existing ea set as reqd. , providing and fixing of battery terminal socket set for dg starting battery incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve suitable for 7.5 kva to 32.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kva to 125 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 7.5 kva to 62.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 75 kva to 250 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of ignition switch or push button for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of engine start key switch incl. testing , commissioning etc. as reqd. , providing and fixing of oil pressure guage for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of water temperature guage for ea set incl. testin
Tender For a) supply of three phase 4 wire tvm energymeterltct operated energy meter with only forwarded mode,isi marked with lcd display, calibration led, battery backup,amr compliance and provision of sealing on meter body and terminal cover