Web Analytics Made Easy - StatCounter

Couplings Tenders

Get complete information related to latest Couplings Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Couplings Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Couplings Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39926849 Due date: 26 Apr, 202526 Apr, 2025 NA
Tender For corrigendum : tender for supply of couplings - hub and sleeve assembly , spacer and adapter assembly , solo plate , output coupling assembly , hub and sleeve assembly , spacer and adapter assembly , solo plate

Central Government/Public Sector

CTN :39952996 Due date: 25 Apr, 202525 Apr, 2025 26.90 Lacs
Tender For corrigendum : shifting of 06 nos. of transformer tsu315kva, 3.3 kv / 570v with all electrical equipments and shifting of main acb, coupled acb for proposed development and depillaring panels at seam vii and vi(b) khairaha ug mine

CTN :40062013 Due date: 03 May, 202503 May, 2025 2.53 Crore
Tender For procurement and installation of different instruments for instrumentation of earth dam and spillway in deo irrigation project for the year 2025. - supply of fiberglass reinforced plastic (frp) make universal enterprises an improved venturi plate conformed to is: 9108 for accurate measurement of water flowing through channels comprising of masonry construction provided with pre-fabricated glass fiber lining on both sides, a side chamber provided in one side masonry wall of the said flume on the upstream side, a pipe provided at the bottom of the chamber connecting the said chamber with the water flowing through the notch, a float means provided in the said chamber, enabling recording the rising or falling level of water in the said chamber such as a scale provided in the said chamber, moulded engraved gauge marking in lit/sec and also in centimeter including moulded and engraved discharge table, capacity marking, flow direction, m.s pipe stiffeners, hold fasts, sand treatment on the backside of plate but excluding gst as per the instruction of engineer-in-charge etc. complete, inside spillway foundation gallery - 15 lit./sec. v-notch, seepage drain - 90 lit./sec. v-notch, calibration marks:- supply of polymers composites improved calibration marks make universal enterprises with contact molding process, both side finish, m.s. strip embedded inside, engraved and molded marking for bands and figures covered with radium and covered with two coats of polyurethane for surface protection with marking in reduced levels, sill, fsl, frl, mwl but excluding gst as per the instruction of engineer-in-charge etc. complete, supply vw up-lift pressure meter provision for connected to das make : aimil ltd. uplift pressure meters are used for measuring and recording of uplift pressures acting in foundations of concrete/masonry dams. vibrating wire type uplift pressure meter : range: 0.2 mpa to 5.0 mpa./7ksc accuracy: 0.5 -1 % fs. temp limit: - 10 to 70 deg c. coil resistance: 140 - 160 ohm thermistor: ysi-44005 or equivalent. material: stainless steel cable: 1m, 4-core borehole for uplift pressure meter at foundation gallery (inside spillway) should be straight from foundation level and clear. proposed location : inside spillway foundation gallery in overflow section: 7 no. non overflow section: 2 no. purpose: uplift water pressure measurement. (but excluding gst), supply automatic seepage measuring system make : aimil ltd / sysgeo italy or equivalent vibrating wire water leakage measuring systems are used for measuring water leakage and flow in dam galleries by installing v notch weir coupled with vibrating wire sensor for remote monitoring of water leakage. sensor type: sensor : vibrating wire precision water level sensor range: 300mm resolution: 0.025%fs material : stainless steel excitation : sweep or pluck assembly: v.w. type sensors enclosed in an environmental proof fibre glass box. splicing kit & adhesive required accessories. proposed location : inside spillway foundation gallery: 1 no. toe drain: 1 no. (drainage outlet) purpose: seepage water measurement in liter per second (but excluding gst), supply data logger or data acquisition system aimil make dt85g with cem20 or ace s korea analog channels 16 analog input channels each channel is independent and supports: one isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or three common referenced 2-wire inputs. expansion requires optional cem20 sampling integrates over 50/60hz line period for accuracy and noise rejection maximum sample speed: 40hz effective resolution: 18 bits linearity: 0.01% common mode rejection: >90db line series mode rejection: >35db vibrating wire frequency range: 500 to 5khz coil resistance: 50 to 200 stimulation method: single pulse pluc digital channels 8 bi-directional channels input type: 8 logic level (max 20/30v) output type: 4 with open drain fet(max: 30v, 100ma) 4 with logic output alarms power supply , sim card will be in your scope. propo

Central Government And Public Sector

CTN :40066284 Due date: 08 May, 202508 May, 2025 4.94 Lacs
Tender For supply of firefighting related equipment for teesta low dam 4 ps - non-percolating fire fighting hose along with delivery couplings , non-percolating fire fighting hose along with delivery couplings , short branch pipe nozzle tip size 15 mm , rubber hose dia 3 by 4 inch hose , hose reel nozzle with shut off type , hydrant landing valves oblique flanged , fire hose reel drum with rubber hose shut-off nozzle

Central Government And Public Sector

CTN :40068898 Due date: 30 Apr, 202530 Apr, 2025 NA
Tender For supply of hydraulic flat face quick couplings (q3)

State Government

CTN :40049068 Due date: 14 May, 202514 May, 2025 NA
Tender For supply, delivery and installation of different electro-mechanical accessories at loba pwss under bolpur mechanical division, phe,dte. - supply and delivery at site of following vertical submersible pumping machinery directly coupled with wet winding type suitable size submersible motor with following specification: method of starting : dol / s/d, shaft-s.s, impeller- s.s / crome steel / gm, outlet - 80/100 mm dia motor : operating voltage : 415 ( 10 %), phase : 3ph, 50 hz 6%speed : 2900 rpm, method of starting : s/d(make : ksb / grundfos / texmo / cri / kbl / mbh / or any approved vendor.) ( n.b : manufacturers test certificate along with charecteristics curve and gurantee certyificate have to be submitted at the time of delivery.), a)discharge (q) : 20m /hr.head (h) : 36 mtrs., b) discharge (q) : 27m /hr.head (h) : 42 mtrs., c) discharge (q) : 27m /hr.head (h) : 51 mtrs., d) discharge (q) : 30m /hr.head (h) : 57 mtrs., installation of submersible pumping machinery to newly sunk tubewell along with column pipes (as required), top cover, valves, and specials of above with protection pipe and supply of ms clamp, nut bolt, cable gland socket etc. making inerconnection of the pump delivery line to pump collecting main line near tubewell with supply of all necceasary pipe, reducer/enlarger, gi/ms specials etc. including brick, sand, cement, rod etc and laying & drawing of all actuator cable & cable protection pipe as required and all to complete the job including all connection & testing commissioning as per direction of eic., add: gst @ 18% on sum of item no: 1.00 to 2.00, add: cess @1% on sum of item no. 1.00 to 3.00

CTN :40069535 Due date: 28 Apr, 202528 Apr, 2025 NA
Tender For supply of high pressure fire fighting hose with delivery couplings as per is 14933

Central Government/Public Sector

CTN :40044776 Due date: 28 Apr, 202528 Apr, 2025 NA
Tender For procurement of fluid couplings premium make for conveyor system at ahp,ncps dadri

Central Government/Public Sector

CTN :39946448 Due date: 26 Apr, 202526 Apr, 2025 NA
Tender For corrigendum : supply of couplings and other assy - coupling f looper output shaft,hsm 6785 , coupling f looper motor shaft,hsm 6787 , table,transfer,dwn hsm 8386 , hinged plate for finishing,dwn hsm 6212 , rocker balance beam,dwn hsm 9857 , e2 bottom anvil assly,064.297.0941.006
 Loading, Please wait...

Connect us via What's Up