Get complete information related to latest Craniotome Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Craniotome Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Craniotome Tenders.
Tender For e-tender for annual maintenance contract for arresting oil leakage in joints, bolts of various equipment such as ict, ct,pt, cvt, reactor, etc.(as & when required basis) by using transformer oil leakage arresting sealant method (the sealant tested by astmd 790, astmc 794, astmd 149 & astmd 1002) at 400/220kv koradi-1 substation under 400kv rs (o&m) division, koradi.
Tender For dismantling of existing porcelain lightening arrestors, surge counters, cvts, acsr conductor, supporting porcelain insulators, supporting structures, complete form line side insulator to takeoff tower for 66kv shimoga bhadra lines 1, 66kv shimoga bhadra lines 2 and lh transmission lines.2)2)supply, erection, testing and commissioning of 3 nos. of 66kv transmission line equipments like cvts, polymeric lightening arrestors with surge counters, supporting polymeric insulator stacks, lynx acsr conductor, clamps, connectors, structure etc. complete from line side isolator to take off tower of 66kv transmission line equipments from line side isolator to take off tower at bhadra generating station.3.dismantling of existing 72.5kv, 0.5cl current transformers, supply, erection, testing and commissioning of 0.2 class, 72.5kv current transformers for 12mw river bed units 1 and 2 at bgs.4.supply of essential spare 04 nos. of 66kv polymeric insulator stack and 01 no. of 0.2cl 72.5kv current transformer.5.jungle clearance along the lines wherever necessary.6.the scope also includes testing at works before dispatch, pre-commissioning and commissioning tests at site and the performance guarantee tests in respect of 72.5kv cts, 60kv las, 72.5kv cvts required for bhadra generating station.7.the scope of supply shall include all accessories, marshalling box, terminal connectors, wedges, clamps, supporting structure etc., which are necessary for assembly and erection of ct, cvt & la.8.modifications required for foundation and support structures to erect newly supplied cts, cvts and las shall be carried out by contractor at no extra cost.
Tender For annual preventive / breakdown maintenance of equipments at 220/132/33kv substations under 220kv oandm division rishikesh - 220 kv switchyardtightening of 220 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 160 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 220 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work, overhauling of mechanism of 220 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 220 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 220 kv take-off assembly/ moving head assembly/rotary head devive etc. (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer, topping up of sf-6 gas in 220 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 220 kv switchyard., 132 kv switchyardtightening of 132 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 132 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work., overhauling of mechanism 132 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete., replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 132 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 132 kv take-off assembly/ moving head assembly/rotary head devive etc (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer., topping up of sf-6 gas in 132 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 132 kv switchyard., 33kv switchyard:tightening of 33 kv bay equipments (cb, line isolator, ct including all connectors of droppers/runner/jumpers), cleaning of 40 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 33 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles, assistance in testing work., overhauling of mechanism 33 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/ runner/ dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 33 kv terminal connector/clamp/jaw/blade etc. and tighgtening of related equipment (including replacement of minor con
Tender For corrigendum : providing of repair and overhauling service - service and repair of nitrogen unit and cvt servo; service and repair of nitrogen unit and cvt servo; yes; buyer premises