Get complete information related to latest Ct Meter Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ct Meter Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ct Meter Repair Tenders.
Tender For corrigendum : supply of lt miscellaneous items for lt switchgear lt system for the year 2024-25 unit 5 and 6 csctpp chhabra - air flow sensor sl0101, control supply -230v ac, with 1 no +1nc contact, make-ifm or equivalent, dynamic braking resistor 13 ohms/ 9600w, 10% ed, 10 sec. max, ambient 50 degree,make-iresco/equi or equivalent, fan: axial, dia: 250, 230vac, 50hz, 115w, air flow:1610 m3/h (specification attached at annexure-i), fan: axial, dia: 450, 415 vac, 50hz,480 w, air flow:4530 m3/h,speed-1360 rpm,(specification attached at annexure-ii), fan axial 08" ball bring 230v ac 1p-50hz (as per annexure-iii ), relay assly : 4 relay, 2 c/o, 5a/24v dc, with led indication, iron core reactor 3 phase, 0.359mh/45a, 3 ph iron core, 117 uh/240a, make: rishab/ transformer/epi/equi or equivalent, 3 ph iron core, 67 uh/240a, make:rishab/ transformer/epi/equi or equivalent, 3 phase line choke ,in-21 amp,inductance-4.2mh,class-f,freq-50hz,voltage-415v, 3 phase line choke ,in-21 amp,impedance-3%,class-f,freq-50hz,voltage-415v, ct: metering 250/5a, 15va, class 1, ct dim.: 180{w}, 100{d}, 70{h}, window size:20x35mm, front terminals, resin, cast, insulation class:e, type 2, colour:yellow, resin cast insulaed c.t 400/5a,class-1,va-10, resin cast insulaed c.t 400/1a,class-1,va-10, thermal overload relay range 95-120 a, 125hp three phase submersible pump star delta starter with 3-position selector switch (with auto switch), single phase preventer, current overload protection with short circuit protection., aluminium ring type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, 35 sq.mm, 50 sq.mm, 70 sq.mm, 95 sq.mm, 120 sq.mm, 150 sq.mm, 185 sq.mm, aluminium pin type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 10 sq.mm, 16 sq.mm, 35 sq.mm, copper ring type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 2.5 sq.mm, 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, power terminals mounting on din conforming iec 60947-7-1,voltage rating-1 kv,safe for fingers., current rating-140 a, 35 sq.mm,3 nm, current rating-192 a, 70 sq.mm,6 nm, current rating-232 a, 95 sq.mm,6 nm, copper pin type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 1.5 sq.mm(hollow type), 2.5 sq.mm, 2.5 sq.mm(hollow type), 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, copper u type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 2.5 sq.mm, 6 sq.mm, terminals blocks (melamine housing) khaki color, 4 sq. mm, 32 amp., 600v, 10-20awg, screw type, din mounting, 6 sq. mm, 41 amp., 800v, 08-20awg, screw type, din mounting, 6-35 sq. mm, 125 amp., 750v, screw type, din mounting, 1.5-4sq. mm, 32 amp., 800v, 08-20awg, stud type, bolt connection, clip on din mounting, 35-50sq. mm, 125 amp., 1000v, clip on din mounting, wago make grey colour screwless , spring clamp, polyamide terminals for interpanel wiring , terminal:769-251, female plug:769-102 with add-on, modular timing relay,5a,2co,0.1s 100h,on-delay,230v ac, voltage-transducer, suitable for 24v dc power supply,i/p:0-500v ac,dual o/p(4-20ma), din rail mounted,, shunt resistor, 750a/60mv,0-60mv, shunt resistor, 175a/60mv,0-60mv, shunt resistor, 200a/60mv , 0-60mv, thermal overload relay,1.6a-2.5a, 3 pole, bi - metallic, 1 no + nc,, thermal overload relay,16a-25a, 3 pole, bi - metallic, 1 no + nc,, ac axial fan230 vac,50/60 hz 6"172x150x51 mm(model no rec-21725b2w) rexnord make or equivalent for 1:1 replacement, ac axial fan230 vac,50/60 hz 4"120x120x38 mm(model no rec-22038 a2t) rexnord make or equivalent for 1:1 replacement, transformer protection relay,i/p-4 nos of rtd sensors(pt-100),3 no of set points,0-300 temperature indication range,o/p-four relay contacts(01 c/o contacts),one analog 4-20 ma output contacts ,aux supply -90-270 v ac/dc,pecon make ,model no-tr-7570 or equivalent for 1:1 replacement, add-on auxilia
Tender For supply and fitting of safety equipment in six (06) nos. of ece make ocb for compliance of dgms-violation in compressor section of moonidih project, wj area. sl.no. comp no. 2,4,18,11,12,15 - digital earth leakage relay, 30ma-30a, auxiliary supply:110- 240v ac/dc, highly sensitive cbct using nanocrystalline core, id-120mm, electronic motor protection relay (multi protection functions), auxillary contactor/relay, 220v ac, fiber/bakelite board, 6mm (15”x12”), channel connector, led indicator multi voltage, manufacturing and providing of moulded heavy ct with 500/5 a ratio for both protection and metering, manufacturing and providing of pt 550v/220v/110v, push switch with element, kit kat fuse with carrier, make-bussmann/eation, tripping coil 220vac with plunger set, no volt coil, copper wiring wire, ferule, tie & lugs etc., technical charge/labour charge for wiring, armoured cable connection dismantling & fitting, 3 phase voltmeter, size -96mmx96mm, 3 phase digital ampere meter, size -96mmx96mm, buzzer with led indication 220v, painting of switch, testing transformer
Tender For tender for supply of repair replacement of outdoor type current transformer of 33 kv at af stn memaura : : - dismantling of unserviceable outdoor type current transformer ct of 33 kv from 33 oblique 11 kv mrs yard each set of three , disconnecting all existing electrical connection each set of three , supply of outdoor type current transformer ct of 33 kv single phase outdoor oil immersed insulation level 70 oblique 170kv 50 hz ct ratio core i 50 oblique 1a 15va oblique 0 point 5 and core ii 50 oblique 1a 30va oblique 5p 10 dual core one for metering and other for protection complete set of three all as specified and directed make kappa electricals crompton greeves pragati , fixing of current transformer in its existing position and connecting all with electrical connections each set of three , testing and commissioning of the current transformer set of three