Get complete information related to latest Ct Motor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ct Motor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ct Motor Tenders.
Tender For "name of work : (a) provn of 02 x borewells with 25 hp motor and water pipe line connecting to existing over head tank of 50,000 gallon near double story qtr at 506 army base wksp, (b) spl repair/repair/replacement of shutters/doors at all repair bays of 506 abw, (c) repalcement /provn of electric motors and lt drive systems in eot cranes installed at arg bay and brake system of eot cranes installed at bofors section of 506 abw, (d) spl repair to lightening protection sys for mag no 01,03,04,05,06,07,08,10,13,15,17,26,30,31,32,33,35,36,37 electric room near mag no 37 ata old lab & ata proof yard and proof chember at asd of cod, (e)provn of 25 x desert window air cooler with stand ( iron) for jcos/ors in otm bldg of adm area of 506 abw under ge(e) jabalpur (f) provn of borewell for dilip complex alongwith oh filling pt at cmm jabalpur."
Tender For supply of set of self adhesive irreversible temperature indicator sticker for 3 phase tra ction motors. each set consists of 10 no. stickers. make : thermidex/thermax/paper themome ter usa or similar as per annexure attached [ warranty period: 30 months after the date of delive ry ]
Tender For supply of set of motor protection circuit breaker (mpcb), auxiliary contact and miniature circuit breake r (mcb) suitable for use in m/s sidwal & m/s intec make roof mounted cab air conditioning system of thr ee phase locomotives as per clw specification clw /es/3/0096 alt-l. one set consist of 11 items in 22 nos. as per annexure- a. make/brand as per clw item id 2100535. [ warranty period: 30 months after the dat e of delivery ]
Tender For tender for supply of mt spare - 2574 5420 9938 speedo cable 3 2mm dia 3000mm long i i , 2576 4374 0108 4 way system protection valve , 2576 7230 0147 assy handle outer door lh , 2608 5450 4901 relay starter solenoid , 2754 2910 0127 assy sleeve cyl , 2786 0798 9926 starter motor 12 volts , cvd f 4725500 ring spanner 10x 11 mm f1 5120 0002393 , cvd f2341500 combined stop tail lamp , cvd x 4704011 ring spanner 18x19 metric , dld atf 002 x4000600 filter element oil alt no x4001000 , f 4730111 de spanner 5 16 x3 8 bsf , f 4730200 hammer ball peen type 500gms , f 4734811 de spanner 12x13 metric , f 4735000 screw driver 200mm , ncvd 2060 58300104 8 ton jack with handle , ncvd f 4735100 adjustable spanner 8 , x 4700311 de spanner 19x22 metric , 254007100110 water separator , x 4700811 ring spanner 12x13 metric
Tender For set of modified end shield de & nde side with grease cup suitable for 6306 beari ng of od 72 mm and width 19 mm with outlet for excess grease for m/s. samal harand make s ctmb motor of 3-phase locomotives. one sample to be got approved before bulk supply. mat erial to be procured from clw approved sources. [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of mt spare - rear hub bearing , primary shaft , system protection valve , fly wheel assy , hydraulic ram assy , brake chamber spring , big and bearing cell , head gasket , head light assy with motor rh , rear door lock , suspension bush kit , spider bearinig , combination switch , tank vehcoolar , 4st relay 24 , hand control valve assy , isolation switch , o ring tatra
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above