Get complete information related to latest Ctpt Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ctpt Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ctpt Unit Tenders.
Tender For dismantling of existing porcelain lightening arrestors, surge counters, cvts, acsr conductor, supporting porcelain insulators, supporting structures, complete form line side insulator to takeoff tower for 66kv shimoga bhadra lines 1, 66kv shimoga bhadra lines 2 and lh transmission lines.2)2)supply, erection, testing and commissioning of 3 nos. of 66kv transmission line equipments like cvts, polymeric lightening arrestors with surge counters, supporting polymeric insulator stacks, lynx acsr conductor, clamps, connectors, structure etc. complete from line side isolator to take off tower of 66kv transmission line equipments from line side isolator to take off tower at bhadra generating station.3.dismantling of existing 72.5kv, 0.5cl current transformers, supply, erection, testing and commissioning of 0.2 class, 72.5kv current transformers for 12mw river bed units 1 and 2 at bgs.4.supply of essential spare 04 nos. of 66kv polymeric insulator stack and 01 no. of 0.2cl 72.5kv current transformer.5.jungle clearance along the lines wherever necessary.6.the scope also includes testing at works before dispatch, pre-commissioning and commissioning tests at site and the performance guarantee tests in respect of 72.5kv cts, 60kv las, 72.5kv cvts required for bhadra generating station.7.the scope of supply shall include all accessories, marshalling box, terminal connectors, wedges, clamps, supporting structure etc., which are necessary for assembly and erection of ct, cvt & la.8.modifications required for foundation and support structures to erect newly supplied cts, cvts and las shall be carried out by contractor at no extra cost.
Tender For corrigendum : supply of 11 kv/110v copper wound measuring three phase (three single phase cts and one three phase star/star pt) combined c.t.p.t. unit of accuracy class 0.5s of various rating as per specifications, terms and condition of dgvcl tender
Tender For estimate for installation of me (ctptunit) ctr, 200-100/5 a and meter at import-export point at various location of misrod zone and bairagarh chichli zone under htm kolar of city dn. kolar
Tender For rfp for supply of various electrical material at i/a sez-ii, pithampur, distt. dhar (m.p.) - supply installation testing and commissioning of 132kv ct having ratio of 400/1-1-1 a., supply of 33kv ct having ratio of 400/1-1-1 a. as per standart of mpptcl top bottam standard., supply installation testing and commissioning of 220/132/33kv s/s sec.-3 support abt, 3phase 4wire meter, class 0.2s make secure., supply installation testing and commissioning of 200 kva conventional 5star distribution transformer., supply installation testing and commissioning of 18 unit for 12mvar capacitor bank at 132kv s/s, supply installation testing and commissioning of 10kva/48v invertor cum battery for custom office use at niryat bhavan sez-ii., supply installation testing and commissioning of 110volt. 300ah make hertz electronics at 132kv s/s sez-ii., supply installation testing and commissioning of 48 volt. 200ah make hertz electronics at 132kv s/s sez-ii., supply copper control cable 12 core. 2.5 sq.mm. (armoured), supply ct clamp sutable for 11 kv ct, supply 33 kv ttb, supply 11 kv ttb, supply 33 kv vcb, outdoor porcelain clad type with complete structure and accessories including existing control pannel wiring for feeder protection excluding ct & pannel, supply33 kv ct 1200/1 amp as per standart of mpptcl top bottam standard., supply33 kv ct outdoor oil immersed type 400-200/5-5 amp, supply secure meter 0.2 clss accuracy premier series 300 3phase 4 wire, supply 33 kv control & relay panel with over current and earth fault static relay for transformer & feeder protection (avana), sitc 33 kv vcb, outdoor porcelain clad type with complete structure and accessories ct & breaker excluding ct & pannel, supply 11 kv ct outdoor oil immersed type 300-150/5-5 amp, supply handling & installation of 33 kv feeder/xmer vcb complete on foundation & tightening/ alingment of of vcb. with old vcb dismentling, supply handling & installation of control pannel , including stand of suitable size for 33/11kv feeder and transformer control, supply installation testing and comissioning 33kv isolator 800amp. copper contactors., supply dlms compliant single phase electronic meter with data downloading facility & box 5-30 amps secure, genus., supply three phase whole current smart meter with box 10-100 a with data downloading facility & box, supply testing and commissionnng of vcb and control pannel, supply sheet metal meter box suitable for h.t. static travector meters with ttb, supply copper control cable 2 core. 2.5 sq.mm. (armoured), supply copper control cable 4 core. 2.5 sq.mm. (armoured), supply copper control cable 8 core. 2.5 sq.mm. (armoured), supplycopper control cable 10 core. 2.5 sq.mm. (armoured), supply copper control cable 12 core. 2.5 sq.mm. (armoured), supply aluminium cable 2 core. 4 sq.mm. (unarmoured), 2 x c al 10 sqmm cable, 2 x c al 16 sqmm cable, 1 x c copper 2.5 sqmm wire, 100 amps mcb, supply junction box for hymast and street lights with inbuild 100 amps mcb for main supply & 63 amps for outgoing supply for hymast and street lights, supply 16 sqmm cable al 4 x c (four-core) (non-abc) having cloth covering suitable for hymast connection, supply 25 sqmm cable al 4 x c ( four core) armoured cable (non abc) for providing 3 phase supply to hymast, supply pvc insulation tape, supply 4 point connectors for hymast, supply 25 sqmm lugs for hymast cables, supply 2.5 sqmm cu flexible wire, supply pvc tape 2*30(box), supply m seal, supply ferrule (r,y,b,n and 0 to 9) each 1 set, supply pvc insulated pvc sheathed 3.5 core 35 sqmm aluminium conductor 1100 volts, supply pvc insulated 2 core 10 sqmm cable
Tender For segregation of 11 kv mixed feeders at tonk circles of jaipur discom of rajasthan state under revamped reforms-based and results linked distribution sector scheme (rdss) on turnkey basis against tn-583 - pcc poles, pcc pole 9 mtrs long (400 kg), pcc pole 9 mtrs long (200 kg), outdoor 11 kv o/d vcb kiosk complete with accessories including use of special tools, armoured cable of size 2c x 4 sq.mm. 1100 volts pvc insulated including supplyof ferrules, control cable of size 12c x 2.5 sq.mm. 1100 volts pvc insulated including supply of ferrules, overhead steel cored aluminum acsr dog[100sqmm(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing, overhead steel cored aluminum acsr rabbit conductor in all respect, earthing rod sets for s/s made with ms rod (galvanized ) 20 mm dia, 3 meter length with gi wire and clamp as per latest specification and drawing adopted & approved by nigam., ctpt structure set (galvanized), 11kv ct pt set(200/5 amp.), mip meter box for meter with ttb, go double break without eb isolator on existing bracket complete in all respect as required including hardware, nut, bolts & washer etc., 11kv ( with 9 x 24 kv post insulator ) 400 amp., horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc., 11kv ( with 6 x 24 kv post insulator ) 1 set=3 nos, supply of insulators, 11kv porcelain disc.insulators b&s type 45kn, hardware for 11kv disc insulator b&s type 45kn, composite polymer insulators, 11kv polymer disc.insulators t&c type 45kn, hardware for 11kv disc insulator t&c type 45kn, 11 kv composite polymer pin insulator complete in all respect, pg clamps for suitable acsr dog conductor, pg clamps for suitable acsr rabbit conductor, 11 kv danger plate of size 200 x 250 mm complete in all respect, supply of angle and channel, m.s channel 100x50x6 mm, m.s channel 75x40x6 mm, m.s. flat 50 x 6 mm (galvanized), 1.4 mtr channel bracket with clamp, supply of lightening arrestors, substation type 9kv, 10ka station class (1set=3 nos.) lightening arrestors., 11kv double pole line structure set for cut point complete on existing poles in all respect with clamp, as required made from m.s.channel 100 x 50 x ismc ( 9.56 kg. per mtr.) isa m.s.angle 65 x 65 x 6 mm, m.s.angle 50 x 50 x 6 mm and m.s.flat 50 x 6 mm (galvanized as per is), gi stay set (galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300x300x4 mm,12 mm dia turn buckle) including stay clamps,, strain/guy insulator for stay set, 7/10 swg gi stay wire, gi wire 8swg, underground cable for working voltage of 11kv aluminium conductor (is 7098) cable xlpe armoured, under ground cable of size 3x185 sq.mm for 11 kv, g.i. pipe of 125 mm diameter, b-class (is:1239 mark), gi pipe for cable support at pole ( each 3.3 mtr ), cable for11 kv aluminum conductor xlpe armoured ht cable, xlpe 3x185 sq.mm h.s. on indoor type, xlpe 3x185 sq.mm h.s. on outdoor type, xlpe 3x185 sq.mm h.s.s.t. joint, 11.4 mtr. long lattice tower made of 50 x 50 x 6 mm m.s. angle with 50 x 6 mm m.s. flat for bracing as per nigam specification, 11kv cross arm with top hamper with clamps made of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm (galvanized), fixing of 11/0.4 kv substation structure set for three phase 63 kva transformer on double poles in all respect. weight (as per specification and drawing with go channel) approx=219.54 kg (all galvanized as per relevant is), 11 /0.4 kv al wound, three phase distribution transformer (completely self protected with provision of lt bushing box), 25 kva, 63 kva, 6.35/0.24kv s/s structure set for single phase transformer on single 9mtr, 400kg pcc pole in all respects., 11kv 100 amp drop out cum isolator with 3.0 amp. fuse & 12 kv post insulators., lt xlpe cable, size 4cx70 sq. mm, size 4cx120 sq. mm, aerial bunched cable, aerial bunched cable 3cx25+1x25 sqmm, aerial bunched cable 3cx50+1x35 sqmm, lt distribution pillar
Tender For replacement of various items at various 220kv and 132kv substations under etd budaun - a) replacement of old & defective/damaged equipments 132kv & 33kv control panel, relay panel, transfer bus coupler panel/dcdb/110volt ac charger/33kv vcb at various substations under etd, budaun. 1) dismantalling of old/obselete/damaged 132kv control panel/relay panel/transfer bus coupler panel/33kv triple feeder panel/dcdb/110volt ac charger/33kv vcb by opening of all associated control cable and earthing and shifting of above from control room to store., 2) erection of new 132kv control panel/relay panel/transfer bus coupler panel/33kv triple feeder panel/dcdb/110volt ac charger/33kv vcb alongwith foundation modification if required with earthing and cable termination and shifting of above from store to site and other associated works., b ) overhauling of 33kv vcb (mechanical/electrical) 1) mechanical overhauling of 33kv vcb that includes checking of opening mechanism, closing mechanism, spring charge mechanism, changing of pole assembly or vaccum interrupter etc. (01 job per breaker)., 2) electrical overhauling of 33kv vcb that includes checking of tripping circuit, closing circuit, indication, trip cicruit supervision etc. (01 job per breaker)., c ) replacement of old rusted 132kv pt/ct junction box including removal of old junction box after opening all cable termination and installation of new junction box alongwith cable termination and cable laying work (if applicable) (01 job/01juction box), d) replacement of old rusted 33kv pt/ct junction box including removal of old junction box after opening all cable termination and installation of new junction box alongwith cable termination and cable laying work (if applicable) (01 job/01juction box)