Get complete information related to latest Cuplock Scaffolding Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cuplock Scaffolding Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cuplock Scaffolding Tenders.
Tender For supply of furniture -the seat is made of 1.4cm thick hot pressed plywood upholstered with fabric and moulded polyurethane foam. it has aseat depth adjustment of 5cm integrated in the seat through a sliding mechanism. seat size shall be 50cm x 49cm. theback is injection moulded in glass filled polyamide which is upholstered with mesh fabric. the back consist of adjustablelumbar support made of injection moulded polypropylene having an adjustment of 6cm. back size shall be 50cm x 68cm.the polyurethane foam for seat is of density 55 kg per meter cube. the three way adjustable armrests is made of glassfilled polyamide arm structure with pu armtop and height adjustment of 7cm. the armtop has swivel and to and fromotion. the inner tube of armrest is chrome plated. it shall have center tilt synchro mechanism, 360 degree revolvingtype, 3 position locking system with anti-shock feature. the headrest is injection moulded in glass filled polypropylenewhich is upholstered with foam and fabric. the pneumatic height adjustment is chrome plated with an adjustmentstroke of 9cm. the pedestal is high pressure die cast polished aluminium and fitted with 5 nos. of twin wheel castors.the pedestal is 65cm pcd. the overall dimension of the chair shall be 75cm x 75cm x (115-130cm). seat height shall be44.5cm to 53.5cm.this shall come with sliding seat, which helps user adjusting the seat depth as per the user size andneeds. the product shall be certified with the following: cii greenpro, ul greenguard, scs indoor advantagegold, bifma level 2. the work shall be done strictly as per drawing and direction of engineer-in-charge , the seat is made of 1.4cm thick hot pressed plywood upholstered with fabric and moulded polyurethane foam. it has aseat depth adjustment of 5cm integrated in the seat through a sliding mechanism. seat size shall be 550cm x 49cm. theback is injection moulded in glass filled polyamide which is upholstered with mesh fabric. the back consist of adjustablelumbar support made of injection moulded polypropylene having an adjustment of 6cm. back size shall be 50cm x 68cm.the polyurethane foam for seat is of density 55 kg per meter cube. the three way adjustable armrests is made of glassfilled polyamide arm structure with pu armtop and height adjustment of 7cm. the armtop has swivel and to and fromotion. the inner tube of armrest is chrome plated. the chrome plated tubular frame is made of dia. 2.8cm x 0.2cmthick ms round tube. the frame is fitted with plastic caps made of injection moulded glass filled polypropylene. theoverall dimensions of the frame shall be 63.5cm x 59.5cm x 97.5cm. the seat height shall be 42.5cm. the product shallbe certified with the following: cii greenpro, ul greenguard, scs indoor advantage gold, bifma level 2. thefurniture quotation for ae & je civil - hindan airforcefor assistant engineer room:2work shall be done strictly as per drawing and direction of engineer-in-charge. , providing and placing in positionmain table with side table. overall size shall be 2350mm(l) x 1200mm(d) x 750mm(h) with sidetable of size 1250mm(l) x 500mm(d) x 750mm(h). the main table and side table tops are made of 25mm thick mdf with bottomside pre-laminate board confirming to is-14587:1998 and 0.4mm pvc membrane pressed on to top. soft closing access flap withinbuild power box are provided on work surface for wire management. the modesty panel is made of 25mm thick mdf - one side prelaminate board confirming to is-14587:1998 with 0.4mm pvc membrane pressed on to top. the understructure is made of 25mmthick pre-laminated twin board of e1-p2 grade and approved shade confirming to is-12823:1990, edge banded with matching 2mmthick pvc lipping. the drawer unit is made of 25mm thick pre-laminated twin board of e1-p2 grade and approved shade confirmingto is-12823:1990, edge banded with matching 2mm thick pvc lipping. drawer units - drawer fronts made of 25mm thick mdf oneside pre-laminate board confirming to is-14587:1998 with 0.4mm pv
Tender For execution of plan for re-development / construction work for canara bank at 26, south patel nagar, new delhi. (sh- demolishing of existing b & g & 1 distressed /dilapidated and unsafe rcc framed structure old staff quarters i/c disposal of unserviceable materials and crediting of serviceable materials).subwork/packages:sh- demolishing of existing b & g & 1 distressed / dilapidated and unsafe rcc frames structure old staff quarters i/c disposal of unserviceable materials and crediting of serviceable materials..
Tender For execution of plan for re-development / construction work for canara bank at 2/4, west patel naagr, new delhi. (sh- demolishing of existing g&1 distressed / dilapidated and unsafe rcc framed structure old staff quarters i/c disposal of unserviceable materials and crediting of serviceable materials).subwork/packages:sh- demolishing of existing g&1 distressed / dilapidated and unsafe rcc framed structure old staff quarters i/c disposal of unserviceable materials and crediting of serviceable materials.
Tender For construction of first and second floor (multipurpose hall) over the canteen and dispensary block in the new land for niftem at thajavur sw.1 constructing rcc framed structure (vertical expansion of 2 more floors) i/c internal water supply and sanitary installation, civil ,external service connection, oht without independent staging and dismantling and demolishing of rcc/brick work etc., sw-2 internal electrical installations, power wiring and plugs fire fighting with down comer system, automatic fire alarm system,13 passengers lift 1 m/s with power operated doors, electrical external service connection, lighting conductor, telephone conduits ,sitcs of vrf system i/c indoor/ outdoor units, piping illuminated signages etc., sh providing interactive display ,lt distribution panel, supply and laying of ug cable.
Tender For supply of foundation in rcc including excavation and rcc work , structure in steel , walls , flooring , movable stage , doors , windows , ceiling , roofing , lighting and electrical work
Tender For deposit work in the area of edsd-laxminagar under edd-laxminagar, mathura - carriage of 8.5 mtr long pcc pole from 132 kv store center mathura to site of work through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-70 kms.), carriage of 9/11 mtr long st pole from 132 kv store center mathura to site of work through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-70 kms.), carriage of 16 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 25 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 63/100 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 250 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 11 kv xlpe cable size 3x70/3x120 sq.mm. cable form store center mathura/agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends., carriage of 11 kv xlpe cable size 3x185/3x300 sq.mm. cable form store center mathura/agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends., carriage of line material i.e. conductor, g.i. wire tpmo stay rod, disc insulator, cross arm, angle channel and other required material from store center at 132 kv substation mathura to the site of work including loading and unloading of material at both ends., erection of single pole structure 8.5 mtrs on pcc pole by digging of pits fitting of all relevant accessories as per respo norms., erection of single pole structure 9/11 mtrs on st pole by digging of pits fitting of all relevant accessories as per respo norms., erection of double pole structure 8.5 mtrs on pcc pole by digging of pits fitting of all relevant accessories as per respo norms., erection of double pole structure 9/11 mtrs on st pole by digging of pits fitting of all relevant accessories as per respo norms., installation of stay set with grouting and nuzzling etc. as per respo drawing along with all routine material to be used for such works., earthing of poles by fixing earthing rods and binding with earth wire as per standard norms including cost of labour t&p and required material for such work., laying, sagging stringing and binding of acsr weasel conductor on the erected pcc pole/stp including jumpering as per respo manual., laying, sagging stringing and binding of acsr dog conductor on the erected pcc pole/stp including jumpering as per respo manual., laying, sagging stringing and binding of arial bunch conductor on the erected pcc pole/stp including jumpering as per respo manual., laying, sagging stringing and binding of lt pvc cable on the erected pcc pole/stp including jumpering as per respo manual., laying of 11 kv xlpe cable size 3x70/3x120 sq.mm. in the trench/g.i pipe/hdpe pipe and re-dressing of trench after laying of xlpe cable for proper completion of work as per direction of supervising engineer., laying of 11 kv xlpe cable size 3x185/3x300 sq.mm. in the trench/g.i pipe/hdpe pipe and re-dressing of trench after laying of xlpe cable for proper completion of work as per direction of supervising engineer., filing of cable box as suitable size as per direction of supervising engineer., filing of straight through as suitable size as per direction of supervising engineer., chopping of tree branches to clear the route properly., mounting of 16 kva transformer on the double pole/plinth struct