Web Analytics Made Easy - StatCounter

Cyclic Voltammetry Tenders

Get complete information related to latest Cyclic Voltammetry Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cyclic Voltammetry Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cyclic Voltammetry Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :42996059 Due date: 15 Dec, 202515 Dec, 2025 10.00 Lacs
Tender For tender for office equipment, electronic devices and office furniture purchase for training purpose - computer desktopdell 27 all-in-one|14th i7-150u, 16gb ram ddr5 1tb ssd,intel graphics|27" fhd ag,ips, 99% srgb|win 11+mso24+o365|molded speaker grill|intel wifi 6e|5mp pop-up ir camera ms office only branded products will be entertained. warranty 1 year., hp officejet pro 9730 wf aio prntr:in-ena3,a4, all in one printer with duplex printing, adf and a3 scanning, perfect for businessprint/copy/scan with duplex, print speed up to 22 ppm (black) and 18 ppm (color) usb, apple airprint, ethernet, wi-fi, vanrakshak wildlife camera trap | 64mp | 1080p video recording | night vision | motion detection trail camera, thermal drone cameradji mavic 3 multispectral technical specifications of the dji mavic 3 multispectral (dji mavic 3m)- net weight (with propellers and rtk module): 951 g max takeoff weight: 1,050 g dimensions (folded): 223 96.3 122.2 mm (length width height)dimensions (unfolded): 347.5 283 139.6 mm (length width height) diagonal length: 380.1 mm max ascent speed: 6 m/s (normal mode), 8 m/s (sport mode) max descent speed: 6 m/s (normal mode), 6 m/s (sport mode) max flight speed (at sea level, no wind): 15 m/s (normal mode), 21 m/s (sport mode forward), 20 m/s (sideways), 19 m/s (backwards) max wind speed resistance: 12 m/s, chair computer cum office chair. low back chair with two arm rest. made up of pu foam seat and back cushion. handrest pvc material. pushback mechanism with lock system. hydraulic for up and down system. nylon base with wheels upholstery of customer choice., wooden table for desk/ table office/ table for writing/office desk computer desk office cum computer table made up of woodbase board. height 30 inch top size 60 inch * 48 inch with 36 mm border and 18mm board. table with keyboard holder. three drawer and one locker. high quality material is needed., steel almirah 4x7 for office useone locker, four partitions high quality material is needed.

CTN :42901834 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t

Central Government And Public Sector

CTN :42860667 Due date: 12 Dec, 202512 Dec, 2025 NA
Tender For providing of customized amc/cmc for pre-owned products - thermal scanning; --; annual maintenance contract (amc); quarterly; no -pre-qualification criteria 02 , 2. scope of work involved in thermography job 02 , 3. bidder compliance sheet

State Government

CTN :42756414 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopaedia with a de
 Loading, Please wait...

Connect us via What's Up