Web Analytics Made Easy - StatCounter

Data Acquisition Tenders

Get complete information related to latest Data Acquisition Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Data Acquisition Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Data Acquisition Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :41232278 Due date: 18 Aug, 202518 Aug, 2025 NA
Tender For supply of electronic personnel dosimeter-gamma, refer item no.1 of technical specification , electronic personnel dosimeter- neutron refer item no.2 of technical specification , dosimeter reader , refer item no.3 of technical specification , software for dosimeter connection to data acquisition system, refer item no.4 of technical specification , data acquisition system, refer item no.5 of technical specification

corporations/Associations/Others

CTN :40864312 Due date: 05 Aug, 202505 Aug, 2025 534.00 Crore
Tender For corrigendum : survey, investigation, design, supply,laying & jointing of gravity pipe distribution network with gravity main, bleeders, various types of valves from ch. 56.000 km to ch. 65.580 km for providing irrigation to 14520 ha including scada automation works, supply of spares parts and tools, service road, construction of open canal for dy. no-20 to dy. no-24 from ch. 49.920 km to ch. 55.560 km for irrigating 403 ha ica of tidagundi branch canal under mulwad lis stage-iii including operation & maintenance of the system covered under the scope for five years period from the date of commissioning of entire system on turnkey basis.

Central Government/Public Sector

CTN :41223162 Due date: 06 Aug, 202506 Aug, 2025 3.95 Lacs
Tender For supply of supervisory control and data acquisition (scada) lab kit (q3)

CTN :41203935 Due date: 05 Aug, 202505 Aug, 2025 17.25 Lacs
Tender For upgradation of substation control and monitoring system with supervisory control and data acquisition with associated accessories for different 11kv and 3.3 kv circuit breakers at karo sub station

State Government

CTN :41196527 Due date: 07 Aug, 202507 Aug, 2025 31.89 Lacs
Tender For narmada river basin(nr.hafeshwar) based bulk pipe water pipeline scheme (package-2) comprehensive operation and maintenance of the project mainly different class, type and diameter pipes, sluice valves, flow meters, non-return valve, incl.scada system installed at package-1 to 9. work includes replacement of spares for all equipment and maintenance of all civil structures and all electro mechanical installation etc. complete. including submission of periodic mis reports on software. supply of potable water in accordance, all type operations, preventive maintenance, overhauls and repair / break down maintenance for civil / mechanical & electrical works. providing nos. of qualified and experienced staff for overall amanagement of o&m work as per detailed specification & obligatory requirement for 6 months. excluding electric power, raw water cost, chlorine, pac and bleaching powder under dist. dahod as per tender.narmada river basin(nr.hafeshwar) based bulk pipe water pipeline scheme (package-2) at villages of taluka: devgadh baria, dhanpur, limkheda ,garbada,dahod &chhotaudepur,district: dahod &chhotaudepur.

Co-operative

CTN :41198611 Due date: 04 Aug, 202504 Aug, 2025 NA
Tender For supply of instrument spare part all type goods - supply of instrument spare parts & all type of goods, temperature scanner model-85xx mix, input-rtd, pt-100 (3w), range: -199.9 to 200.0 degree, channel: 08, power: 85 - 265v ac, option: rs - 485 modbus protection, make- massibus, popat valve 1" f/e, 5/2 way double solenoid valve 1/4", 220v ac & double coil (5700-6-2g) make- rotex, 5/2 way single solenoid valve 1/4", 220v ac & single coil (3012-6-2g) make- rotex, 3/2 way single solenoid valve 1/4", 230v ac & single coil (3013-6-2g) make- rotex, proximity switch (pnp-sw4051) 3 wire, 400 ma x 3 mtr. long make-jay shree, vibrator card (0 - 100) make- vaidehi international industries, air filter regulator model : al3000 make-akari, pneumatic limit switch model: dp045061 make- janatic, pressure switch model: psm-520-100 (0 - 100 psi) make- indfos, pneumatic limit switch model: psm-520-100 (0 - 100 psi) make- janatic, spear lug centre mounting for cylinder, spear fork mounting for cylinder, spare seal kit for pneumatic actuator (pd-280/4), spare seal kit for pneumatic actuator (pd-500), separator controller mm3010 (make-selec), pneumatic relay for electromagnetic positioner model:8013 (make-mil), pneumatic relay for electromagnetic positioner (make-ytc ) model: yt-1000 ldr 13250, pneumatic relay for electromagnetic positioner (make-forbes marshall ) model: 820-pp, i/p converter current signal (4 - 20 ma), pressure signal (3 - 15 psi) make - abb, signal isolator (massibus make) input: 90-265v ac, dual o/p channel, temperature indicator pic 101 supply 230v ac (make- selec), thermo well ss316, length-120mm heavy duty, thermo well ss316, length-90mm heavy duty, cylinder exhaust valve model no. 3340d make-schrader duncan, solenoid valve model no.:vaj213-2g-24v dc, make- rotex, push male connector size - 8mm x 1/4" make janatic, push male connector size - 8mm x 1/2" make janatic, push joint connector size - 8mm x 1/4" make janatic, electromagnetic flow meter (digital water meter) size 4" body & flange-ms, type-rubber lining, flow rate- 4 digital led, total flow-9 digital led, flow unit-m /hr, line pressure-max. 25 kg/cm2, i/p supply : 230v ac, o/p: 4 - 20 ma, electromagnetic flow meter (digital water meter) size 3" body & flange-ms, type-rubber lining, flow rate- 4 digital led, total flow-9 digital led, flow unit-m /hr, line pressure-max. 25 kg/cm2, i/p supply : 230v ac, o/p: 4 - 20 ma, electromagnetic flow meter (digital water meter) size 1-1/2" body & flange-ms, type-rubber lining, flow rate- 4 digital led, total flow-9 digital led, flow unit-m /hr, line pressure-max. 25 kg/cm2, i/p supply : 230v ac, o/p: 4 - 20 ma, vfd spares abb make model : acs 800+s71200, please mention the make and enclose the price list duly verified and quote discount on price list, vfd spares abb make model : acs 850-04-650-5-u400 please mention the make and enclose the price list duly verified and quote discount on price list, vfd spares abb make model : acs 850-04-580a-5 please mention the make and enclose the price list duly verified and quote discount on price list, vfd spares abb make model : acs 560-145a-04 please mention the make and enclose the price list duly verified and quote discount on price list, vfd spares abb make model : acs 150 please mention the make and enclose the price list duly verified and quote discount on price list, vfd spares abb make model: acs 580 please mention the make and enclose the price list duly verified and quote discount on price list, spares of siemens make cinamics drive model:g130 please mention the make and enclose the price list duly verified and quote discount on price list, spares of siemens make cinamics drive model:g150 please mention the make and enclose the price list duly verified and quote discount on price list, siemens dcs supply of pc & commissioning of system, desktop pc compactable with existing siemens dcs for boiling house operation with siemens software packages, dcs scada

CTN :37462713 Due date: 28 Jul, 202528 Jul, 2025 NA
Tender For bid to ras supply of multi frequency digital signal processing based vme data acquisition (dsp-daq)

State Government

CTN :40985783 Due date: 11 Aug, 202511 Aug, 2025 1.50 Crore
Tender For corrigendum : purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-a

CTN :41212953 Due date: 13 Aug, 202513 Aug, 2025 NA
Tender For supply, installation & commissioning of d.v. test bench with digital pressure gauges and ti mer & pc based data acquisition system. specification details as per annexure, a, b, c. [ warranty perio d: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :41195876 Due date: 14 Aug, 202514 Aug, 2025 NA
Tender For supply of fiber testing unit , inject grouting machine , advance motion capturing-based data acquisition system
 Loading, Please wait...

Connect us via What's Up