Get complete information related to latest Dc Ammeter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dc Ammeter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dc Ammeter Tenders.
Tender For supply of ammeter 90 mm x 90 mm moving coil dcammeter for battery charger range 30-0-30 amps centre zero class 1.5," flush panel" mounting, meco model no m 96 (square quadrant) with rubber gasket sett & de drg. no. 335. or equivelent [ warranty period: 3 0 months after the date of delivery ]
Tender For supply and installation of physics instruments - c.r.o. dual trace 40 mhz: 1. type of input channels- analog and digital (mixed signal)2. number of analog channels-3. bandwidth - 300 megahertz.4. display type -colour tft.5. minimum display size- 10 inch.6. time base accuracy- 2.5 parts per million.7. sampling rate per digital channel simultaneously: 1gs/sec.8.record length per digital channel simultaneously- 8m point., function generator 0.3 to 3 mhz (scientific 10 mhz to 25 mhz frequency 1 channel function generator) : 1. frequency bandwidth (sine wave ) 10 mhz to 25 mhz.2. sample rate of arbitrary waveform generator (mega samples/sec)3. amplitude range (at 50 ohm impedance),10mv to 10 v pp. , multiplexers and de-multiplexer with built in power supply :1. material- abs2. display- digital, verification of de-morgen s theorem with built in power supply : 1. type- digital2. consisting of built in power supply3. logic ics connected internally for 1st & 2nd theorem.4. 2 logic input switches with indcators.5. 1 logic output indicator.6. 3 patch chords to connect input and outputs., encoder and decoder circuit with built in power supply : 1. material- pvc2. equipment materials - glass epoxy front panel with pvc3. temperature range- -5 to 45 celsius4. output voltage(regulated) : 5vdc (internally connected) , half adder, full adder, half subtractor, full subtractor with built in power supply: 1. built-in power supply dc +5 v at 500 ma.2. 3 logic input switches with green led display.3. 3 logic output red led display.4. two and gates ( 7408 ), one or gate ( 7432 )two not gates ( 7404 ) & two ex-or gates ( 7486 ) on panel., hall probe method for measurement of resistivity, complete with hall effect setup, hall probes, digital gauss meter, electromagnet and constant current supply. (complete apparatus) : 1. hall probe (ge crystal);(b)hall probe (inas).2. hall effect set-up (digital), dhe-213. electromagnet,emu-75oremu-50v.4. constant current power supply, dps-175 or dps-50.5. digital gaussmeter, dgm-102.6. range- 0-20 ma, apparatus to study characteristics of tunnel diode : 1. instrument comprises of dc regulated power supply of 0-600mv.1. two round meter for voltage & current measurement.2. circuit diagram is printing on front panel & important connections brought out on front panel.3. with well illustrated instruction manual, photo diode characteristic apparatus : 1. material- ms2. frequency- 50hz, photo transistor characteristic apparatus : 1. instrument type- analog2. input voltage - 220 v3. frequency - 50-60 hz, solar cell characteristic apparatus (complete apparatus) : 1. analog voltmeter: 12. analog ammeter: 13. solar panel/photovoltaic cell/solar cell to study characteristics: 14. range of dc voltmeter (in volt): 305. range of dcammeter (in milli ampere): 506. necessary patch cords for interconnection7. along with instruction manual and demonstration, apparatus to study charging and discharging of a capacitor : 1. built in power supply : +12v variable & -12v, variable dc2. mains : 230v ac , ldr characteristics apparatus. : 1. voltage- 220 v2. apparatus type- analog3. temperature range- 50-60degree, plancks constant using solar cell : 1. instrument type- digital 2. built in power supply : +12v variable & -12v3. necessary patch cords for interconnection
Tender For corrigendum : supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dcammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sens
Tender For provision of generator spares 20kva - connecting rod bearing, std , overfolow line from injector to tank though fip , copper washer 19 mm , exhaust manifold mounting studs with nut , inlet manifold mounting studs with nut , air blower bearing 6204z , brush carrier , dendrite sr-998 , dcammeter 0 to20 ampdc, 72 sqmm , contactor 40 amp , 04 pole with no and nc , temperature sensor , mcb 20 amp , overflow line from filter to tank , 19 x19 - 2 mtr long , cylinder liner standard , water pump mtg bracket , rectifire plate , fuel lifting pump , stop solenoid sw , water pump assy rv3 , field coil for self starter , carbon brush set , self starter solenoid , 1.5 sqmm single core copper wire , injector nozzle , roller assy , piston ring assembly std 3 ring version , recovery tank , push rod tube seal upper red , push rod tube seal lower black , set of benjo bolt 10,13,14,19 , armature rewinding , vaf meter , eng stop solenoid , emergency switch , oil filling cap , oil temperature gauge , alternator assembly , canopy light , mcb 4 pole 63 amp , oil filter , air filter , coolent , over flow pipe , insulation tape , pvc cable 2 core 10 sqmm , flexible clamp silencer , hose clamp , xlpe armd cable 4 core 16 sqmm , amp meter , ignition switch , alternator slip ring , bty terminal positive and negative with lead , relay unit with box , distilled water , fan belt a43 , bty 12 v 180 ah , change over switch 63 amp , frequency meter , air cleaner o ring seal , su , silencer box clamp , armature for self starter , rotating diode , fan belt a50 , terminal block , door hinges , exhaust fan , alternator belt , esu , air element , bridge rectifier , solenoid sw for self starter , regulator for alternator , oil pressure sw , main bearing , fuel pump element , avr , head gasket , hose for air cleaner , dc volt meter , oil pressure gauge , 4 st relay 12 vdc , dc indication lamp , liner shim copper , fuel tank hose 2.5 inch , fuel tank cap , fuel line from fuel tank to feed pump - 19x19, 1.5 mtr long , pressure union nrv 19 mm , fuel filter 0.5 ltr primary and secondary , plunger returning spring , delivery holder copper washer , delivery holder o ring , thrust washer , oil sump drain plug 24 mm , oil filter element , copper washer 17 mm , hose by pass , benjo bolt 10mm with washer , benjo bolt 14mm with washer , connecting rod small end bush , oil pressure pipe line oil main gallery to cylinder head , oil pressure switch llop , fan belt b 49 , hose from radiator to water pump , radiator cap , radiator attachment mounting pad , water temp sensor , water temp gauge , expansion bellow , set of copper washers , anabond 666 t max 200 gm
Tender For supply of electrical spares - direct online starter , contactor 3 pole 50 amps , contactor 3 pole 25 amps , s.s gate wall 1-inch , s.s gate wall 1by2-inch , k type thermo couple length 1ft min , k type thermo couple lentgh 2ft min , digital temperature controller range 0 - 100 c , dcammeter range-0-300 a 75 mv dc class aux supply 230v ac with rs 485 connector , dc voltmeter - model dcv range 0 to 60v dc class 1.0percent of fsd with rs 485 connector 80-285v dc , dcammeter - model dca range 0 to 5000 a by 75 mrde calss 1.0 percent of fsd with rs 485 connector , timer md t 1310 multi span range 0 to 99.9by 999 sec by min , 12v smps , 100a mccb 4 pole