Get complete information related to latest Delegate Unit Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Delegate Unit Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Delegate Unit Repair Tenders.
Tender For procurement and installation of audio visual solution - sitc integrated audio system , sitc display system , sitc , sitc cables connectors and accessories , engineering cost for all the equipment
Tender For corrigendum : notice inviting tender for supply, installation, testing and commissioning (sitc) of audio visual (av) equipment at the city campus of iim sirmaur, paonta sahib
Tender For supply, procurement and execution of technology installation with interior works of orientation hall with audio visual and interactive equipment, av content, at odisha state museum, bhubaneswar with approved specification
Tender For repair and overhauling service - short refit of in asset com 0995 sdp sr o l 25 a; any other suitable brand; no; buyer premises, service provider premises-dock bed preparation including marking, block placement, rigging up of centrelines and preparation of wooden keel/shape blocks as per docking plan. (a) the firm is to provide manpower for rope handling for docking/ undocking of slave dock pontoon as per docking schedule. (b) normally, one docking is envisaged. secord docking is catered to address exigencies, if any arises or to cater for operational requirements (c) cost of additional docking/ undocking operations of the pontoon, emerging due to delay in refit attributable to the contractor, is to be borne by the contractor. (d) fire sentry with portable fire-fighting appliances as well as physical security of contractor items/ material during dry-docking/ refit period are to be catered by the contractor. item no 1 2.00 nos 1.0002 002 cleaning of underwater hull post docking, external hull surface of the pontoon to be cleaned by high pressure fresh water jet washing (3000 psi) immediately after docking. item no 2 1950.00 sq.m 1.0003 003 provision of scaffolding, positioning and staging for undertaking survey, renewal/ repairs, surface preparation and painting of sdp. nb: (a) the principles dimensions of the pontoon are as follows:- size of slave dock pontoon 86m(l) x 16m(b) x 2.8m(h) (b) scaffolding material will be provided by nd(v) item no 3 1500.00 cum 1.0004 004 (a) undertake visual survey of all structural members including complete external hull surface, weather deck, access ladders and all internal tanks, manhole covers and deck fittings. item no 4 15000.00 sq.m 1.0005 004 (b) usg survey is to be undertaken for the suspected areas as per recommendations of class society (to be paid on actual). item no 5 5000.00 sq.m 1.0006 004 (c) hull survey and action taken reports is to be approved by any one of the in approved classification society (abs/bv/dnv/irs/classnk/lr/rina). nb:- (a) surveys are to be undertaken through qualified inspection services provided firm, recognised by any one of the in approved classification society, as indicated above. (b) renewal of corroded/ damaged areas to be recommended through survey i.a.w class standards or no 01/15. ndt, post repairs, to be undertaken as per class society norms. (c) tanks repaired by build-up/renewals are to be air pressure tested. (d) usg gauge and all associated equipment for survey to be provided by firm. robotic survey methods may be used by the contractor to save labour and time. (e) all deck fittings to be surveyed, repaired and load tested where considered necessary as per class standards. (f) all manholes to be inspected and repaired to ensure water tightness item no 6 1.00 set 1.0007 005 metal built ups to be carried at indicated location i.a.w class standards or no 01/15 requirements. nb: (a) build up followed by fairing by grinding to be undertaken. (b) to be undertaken as per survey report (to be paid as per actual work done) i.a.w class standards or no 01/15. item no 7 100.00 sq.m 1.0008 006 scantlings/ hull structural renewal of corroded/ damaged areas as per survey. nb: (a) renewal to be undertaken as per class standards or no 01/15. (b) to be undertaken as per survey report (to be paid as per actual work done) (c) ndt/ dpt is to be undertaken for renewal areas. (d) material is to be catered by the vendor item no 8 10.00 tonnes 1.0009 007 air pressure testing (apt) to be undertaken for all tanks/ chambers as per class standards to prove wt integrity post repairs as indicated at note- 4(b) above (to be paid on actuals). nb: (a) all equipment/ set up (including temporary fixures and their removal after test) are required to be catered by contractor. (b) pressure test:- (i) a test pressure of 150 mm water gauge is to be applied and pressure source isolated. the pressure drop if any, should then be monitored. (ii) any drop in water gauge reading should not ex
Tender For custom bid for services - repair and maintenance of ac modules dc modules and various pcbs of all departmental drilling rigs of ongc tripura asset-work includes but not limited to supply of men, materials, testing equipment / tools etc for fault finding (trouble shooting), repairing, calibration and functional testing of ac modules, dc modules and various pcbs in e1400 series drilling rigs of tripura asset. broad details of the activities to be carried out are as below: a. following jobs are to be carried out in pcbs i. physical checking of healthiness of components & cleaning of the pcbs. ii. checking of voltages at different points in the pcbs after powered up through simulator. iii. replacement of faulty components, limited to 50% cost of the pcb, to make it operational. iv. calibration of pcbs v. on load testing of 12 hrs. continuous loading for satisfactory operational vi. fixing of pcbs in the respective panels b. following jobs are to be carried out in ac module i. visual inspection of module for any loose hardware & cleaning of the module. ii. checking of circuit by using simulator. iii. checking of over frequency tripping. iv. checking of under frequency level. v. under frequency voltage cut back test vi. idle-run ramp and idle trip test vii. throttle regulation check viii. master slave and command circuits check ix. current demodulator check x. automatic voltage regulator check xi. meter circuit check xii. over voltage trip check xiii. reverse power trip check xiv. frequency demodulator check xv. module panel meter check xvi. replacement of faulty components, limited to 50% cost of the ac module, to make it operational. xvii. on load testing of 12 hrs. continuous loading for satisfactory operational xviii. fixing of ac modules in the generator panel c. following jobs are to be carried out in dc-module i. visual inspection of module for any loose hardware & cleaning of the module. ii. dead band and current limit calibrations iii. zero throttle interlock circuit test iv. firing circuit test v. speed feedback circuit test vi. power limit circuit test vii. slave circuit test viii. manual voltage circuit test ix. over current trip calibration test x. meter circuit check xi. replacement of faulty components, limited to 50% cost of the dc module, to make it operational. xii. on load testing of 12 hrs. continuous loading for satisfactory operational xiii. fixing of dc modules in the dcpcr panel d. following jobs are to be carried out in battery charger i. visual inspection and cleaning of components such as transformer, voltmeter, ammeter, pcbs, rectifier, indication lamps and tightening of loose hardware, if any. ii. checking of tripping logics, dc under voltage, dc over voltage, reverse polarity, ac mains fail, over current, over temperature etc. iii. replacement of faulty components, limited to 50% cost of the battery charger, to make it operational.-msme exemption - no | startup exemption - no