Get complete information related to latest Demulsifier Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Demulsifier Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Demulsifier Tenders.
Tender For hiring of chemist services for supervision and testing services with lab instruments, reagents glass wares, consumables etc. required during chemical cleaning activity of boiler#2 at 3 x 800 mw pvunl patratu site for 14 days
Tender For corrigendum : procurement of lab instruments for chemical lab of ogcd, dtps, htps, kasimpur - sension5 portable conductivity meter specification range:#conductivity s/cm 0 to 19.99; 200 to 1999#conductivity ms/cm 2 to 19.99; 20 to 199.9#tds: 0 to 50,000 mg/l as nacl salinity: 0 to 42 g/l (ppt)#temperature: -10.0 to 105.0 c#resolution:#conductivity 0.01; 1.0#conductivity ms/cm 0.01; 0.1#tds: 0 .00-199.9 mg/l 0.1mg/l 2 00-1999 mg/l 1 mg/l 2 .00 -19.99 g/l 0.01 g/l 2 0-50 g/l 0.1g/l #salinity: 0.1 g/l (ppt)#temperature: 0.1 c#accuracy:#conductivity: 0.5% in the first 3 ranges, 1% at highest range #td of full scale #salinity: 0.1 ppt (-2 to 35 c) #temperature: 0.1 c# , make-hach, ph meter probe (ph meter sension ph3) cat no-lzw5010t.92.0002 make hachdetails in photograph enclosed in tender document, manual sieves shaker (with sieves set - mesh size-50,+100,+200) any standard make details in photograph enclosed in tender document, centrifugal machine for oil testing, any standard maketube capacity:no.12-24:size 15 mlshould have a digital timerbody should be made of strong fabricated & corrosion resistant steel.control panel- for start/stop switch, dynamic brakes, step less speed regulator with zero start switch & speed indicator with timer and protective fuses.door interlock.maintenance free brushless drive motor with exact speed preselection and display. speed range 100 to3000 rpm and above, accuracy 1 rpm. details in photograph enclosed in tender document, orset appratus (complete set), any standard make details in photograph enclosed in tender document, ph 2700 ph meter specification #ph range -2.000 to 20.000 ph #resolution 0.1 / 0.01 / 0.001 ph #accuracy 0.002 ph + 1 lsd #cal. points up to 6 preset or 5 custom #buffer sets usa, nist, din, user 1, user 2, custom #or range 2000.0 mv #rel. mv range 2000.0 mv on 0.1 mv# accuracy 0.2 mv #temperature,range (meter) 0.0 to 100.0 c / 32.0 to 212.0 f #resolution 0.1 c / 0.1 f #accuracy 0.3 c / 0.5 f #compensation atc / mtc #power requirements 9 v dc adapter, 1.3 a (100/240 vac, smps)# make- eutech
Tender For tender for supply of chemical vulcanizing fluid l liter packing lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.701076 400380101 0000. , precured patch for cut size tyre patch-injury 2 inch(50mm) 16 pr lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.7010 751 8038 0106 0006 , redial patch ct-12 size 60x110mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010757203801000000 , redial patch ct-20 size 75x125mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010757803801000000 , redial patch ct-26 size 75x250mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010758403601010001 , redial patch ct-35 size 125x150mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010758403801030003 , redial patch ct-40 size 100x200mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010758603801000000 , redial patch ct-45 size 195x230mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.npn , two way tube repair unit patch 25 mm (1.00 inch)mini round 1 packet containing 50 patches lab test test carried out as per specification no.as 164 69 july 2005 as per 10asrtu code no.7010770703801000000 , two way tube repair unit patch 30 mm (1.1/4 inch) small round 1 packet containing 40 patches lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.7010770903801000000 , two way tube repair unit patch 53 mm (2.1/8 inch) medium round 1 packet containing 30 patches lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.7010771103801000000 , two way tube repair unit patch 75 mm (3 inch) large round 1 packet containing 30 patches lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010771303801000000 , two way tube repair unit patch 100 mm (4 inch) round lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.7010771503801000000 , two way tube repair unit patch 118x37mm (4. 1/2 inch to 1. 1/2 inch) small oval patch 1 packet containing 100 patches lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.7010772703801000000 , two way tube repair unit patch 130x75mm(5. 1/4 x 3 inch)medium oval patch lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010773103801000000