Get complete information related to latest Deuterium Lamp Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Deuterium Lamp Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Deuterium Lamp Tenders.
Tender For supply, installation, testing, commissioning of led luminaries along with 5 years of comprehensive operation & maintenance (amc) at urja stadium, bsphcl colony, patna.
Tender For supply of 1- supply & installation of 90 w led street light for replacement of old conventional light as per , 2- supply & installation of 18-20 watt batten with occupancy sensor integral led 4ft luminaries with
Tender For supply of motor, mn 16, 3 phase 440 v 50 hz , led bulb 9 watt , led bulb white 10 watt light 90 percent energy saver high efficiency led lumeno 10w lamp , led white bulb 12 watt , led white bulb 7 watt , fusible plug 3 oblique 4 inch , lead pig , lead wool , non return valve 100mm dia with gm working parts , pp-r elbow 90, of size 32mm. , pp-r elbow reducer 32mm x 25mm. , pp-r female threaded socket of size 25mm - 1 inch dia , pp-r gate valve 25mm. , pp-r male threaded socket of size 25mm - 1 inch dia , pp-r socket 25mm. , pp-r tee 32mm. , pp-r union 25mm. , pp-r union 32mm. , relay ptc for 1 oblique 3 hp motor , rubber tubing for joint leakage , sodium carbonate for water treatment , accessories for exhaust fan 300 mm sweep but ventilator lower shouter , box type relay for water cooler 230 v,50 hz , suitable for 40 oblique 80 ltr cap , cable jointing kit 11kv, 95 sqmm 3 core out door , compact switch disconnect fuse unit of current ratting, ac 32 amp, 2 pole 415 v , capacitor 4 mfd , drop out copper tinned barrel fuse element of capacity 20 amps 11 kv , exhaust fan motor for water cooler 1 oblique 5 hp, 25w , heating element 1500 watt p type , heating element 230 v 2 kw triangle type , integrated ip20 led batten with surface oblique suspended mounting , 110lm oblique w , lead connection for geyser 600 mm as per sample , led lamp 18 watt 419mm ultra bright pl-l 4 pin stright line pin , led post lantern ideal to lit up parks, garden ways . ip 65 20 watt , metal clad plug top 15 oblique 20 amp , molded case circuit breakers ac-415v load line mccbs 63 amps 10ka fp , multi core round pvc insulated pvc cable 1.5 sqmm copper conductor three core , over load relay for refrigerator as per sample , plug top outlet 15 amp 3 pin , plug top outlet 5 amp s oblique t , poly cab flexible cable 3 core 1.5 sqmm , pvc copper cable 1.5 sqmm 1 core , pvc copper cable 1sqmm 1 core , pvc insulated multi standard single core cable with copper conductor 1100v of size 4 sqmm , pvc almn cable 2.5 sqmm 1 core , pvc cable 1.5 sqmm copper conductor twin core , pvc cable almn conductor 1.5 sqmm 1100v s oblique c , pvc casing caping 25mmx12 mtr , pvc copper cable 2.5 sqmm 2 core , pvc copper cable 4 sqmm 2 core , pvc copper cable 6 sqmm 1 core , pvc insulated industrial twin twisted copper conductor flexible wire with copper conductor of size 23 oblique 0.0076 , pvc insulated multi strand flame retardant frlsh single core cable with copper conductor 1100v 6 sqmm , pvc insulated multistrand single core f oblique r cable with copper conductor 1100 v of size 01 sqmm , pvc insulated single core sheathed with solid cable 4 sqmm with alumn cable conductor , pvc insulated two core sheathed with solid cable 4 sqmm with aluminum cable conductor in roll of 100 mtr , rccb having ip 20 protection 6 oblique 10 ka briefing cap with scpo current rating 63 amps sensitively 100 ma , recess mounting bottom opening led luminaries 2x2 crca powder coated housing 50 watt ip54 , running capacitor for ac 50 oblique 60 mfd 230 volts 50 hz , sheet metal enclosure with two pin and earth plug with 20 amp spn mcb , star - delta starter for 25 hp motor fully automatic contractor size 32 over load relay , star delta for 15 hp motor make-havells cosmic star-fully automatic star delta starter asd , thermostat for geyser , thermostat switch for deep freezer 230 v 50 hz as per sample , ultra modern recess mounting luminaries 34 w suitable for ceiling fitting complete with separate electronic driver and high brightness smd adjustable sleaves for refrigerator 286 ltr, adjustable sleaves for refrigerator 300 ltr, compressor for refrigerator, bid details/ 2 / 97
Tender For corrigendum : procurement of different types of led luminaries at bkdam,tiph, switchyard,transformer yard area under of emoph dept. at bktps.
Tender For supply, installation, testing and commissioning of different types of led luminaries in departure and arrival single and double heights area of nscbi airport passenger terminal building, kolkata.
Tender For supply, installation, testing and commissioning of different types of led luminaries in departure and arrival single and double heights area of nscbi airport passenger terminal building, kolkata.
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - rota-evaporator the rota-vapour should have a vertical condenser for standard applications with cooling surface area of 1500 cm2 or better with a protection class of ip20 or better. the rotation speed of the instrument should be 20-280 rpm or better. the water bath should have controlled temperature range of heating within a range of 0-90oc or better with a capacity to accommodate evaporating flask from 50-4000 ml with same joint. all glass components should be made of borosilicate 3.3 glass. digital interface of 4 inches or better to facilitate monitoring of temperature, speed and vaccum. there should be a provision of power cut off when actual temperature exceeds set temperature or by rapid temperature increase. the system should have timer function to regulate the time of the process and automatic aeration when pressure reaches above 1400 mbar. the entire system should have ce/csa approvals. the vaccum pump should be made up of chemically resistant ptfe diaphragm vacuum pump with a suction capacity of 1.5m3/h or better with 2(2) number of steps(heads). the final vaccum should be 7-10 mbar. the recirculating chiller should be of 3l capacity with a working temperature range of room temperature to -10oc and a cooling capacity of 500 w at 15oc., ft-irthe ftir instrument should have transmission interface which provides classic infrared sampling for the measurement of solids, liquids or gases. the transmission module is purgeable and preferable to come with a standard cardholder. the scan range should be from 8000-350 cm-1 with a spectral resolution of 0.5cm-1 or better. the signal to noise ratio: 35000:1 or better. the system should have michelson type/ rock solid/self-compensating, dynamically aligned interferometer which removes any tilt and shear scanning error with 10 years warranty on interferometer. the system should have temperature stabilized or dtgs detector/ temperature control dlatgs detector. kbr/ znse beam splitter to meet complete spectral range. the system should be operable through a windows 10 compatible software with self-diagnostic after initialization, provision for creation of library. the software should have spectral, peak and text search function. the software should be capable of comparing spectrum, quantification and photometric data. there should be a provision of digital humidity level monitoring in internal optics through software and customized template. the system should be supplied with following accessories.hydraulic press for kbr pellet preparation software recognize diamond atr accessory with force monitoring for quick analysis of different sample) solid, liquid, paste and gels) of food, raw material, packaging material etc.installation, familiarization at installationpccorei5, 4gb ram, 1 tb hdd, 18.5 led/lcd, windows 10 , uv visible spectrometer microprocessor based wavelength range: 190 to 1100 nm with 7-8 inch led display. the system must have pre-programmed methods for water parameters which should be compatible with available reagents for the water testing. system should be true double beam uv-visible spectrophotometer with 8-cell changer the monochromator should be blazed czerny-turner type with 1200 lines/nm blazed grating. the detector should have si-diodes/ccd. system should have wavelength range from 190 to 1100 nm or better system spectral bandwidth should be 1 nm (190 to 1100 nm) wavelength setting should be 0.05 nm wavelength accuracy should be 0.3 nm wavelength repeatability should be 0.1 nm or better scan speed max 6,000 nm/min or better photometric range absorbance : -4 to 4 abs transmittance range should be : 0 % to 400 % photometric accuracy should be less than 0.005 abs at 1.0 abs light source tungsten halogen lamp & deuteriumlamp photometric repeatability 0.0002 at 0.5 abs baseline stability: 0.0003 abs/h operating system (os): system should have to
Tender For corrigendum : maintenance of electrical installation & fans in non residential building in sch a & b president estate rashtrapati bhavan new delhisubwork/packages:making e & m arrangement for opening of amrit udyan at rashtrapati bhavan new delhi for general public and providing of self service visitor rgistration kiosk led video wall & decorative luminaries on hiring basis during february & march year 2025
Tender For supply of various items for the dhr project entitled molecular biology applications research and diagnostic techniques - laboratory items, pc based true double beam uv-visible spectrophotometerspecification:1. optical system: czerny-turner mounting, single monochromator, double- beam system, 1,300 lines/mm, 240 nm blazed holographic grating 2. light source: deuteriumlamp and tungsten-halogen lamp 3. detector: r-928 photomultiplier tube 4. wavelength range: 185 to 900 nm or higher 5. wavelength accuracy: 0.1 nm (656.1 nm) 6. wavelength repeatability: 0.05 nm 7. spectral bandwidth: 0.1, 0.2, 0.5, 1, 2, 5 nm in steps 8. resolution: 0.1 nm 9. stray light: max. 0.005 %t (220 nm nai) 10. mode: abs, %t, %r, 11. photometric range: -5 to 5 abs12. noise level: 0.00003 abs rms (500 nm) 13. wavelength slew rate: 14000 nm/min 14. wavelength scan rate: 4000 to 0.5 nm/min 15. below items must be supplied along with the main instrument:a) one pair of cuvettes, 10 mm path length, 3.5 ml volumeb) integrating sphere attachmentwavelength range: 220 nm to 850 nm or betteri) samples like powder, solid, colloidal sample, thin film etc are measured by using thisaccessoryii) minimum inner diameter of integrating sphere: 60 mmc) branded i5 pc with original os- 1 no, class ii, type a2 bio-safety cabinetspecification: 1. the bio-safety cabinets should be 4 feet width with front window must be a 10 sash opening and steel with smart coat interior 2. the bio safety cabinet must include dc motors. 3. the motor must automatically adjust the airflow speed without the use of a damper to ensure continuous safe working conditions, even without maintenance adjustments. 4. cabinet must use a pressure sensor (rather than anemometer) to detect pressure drop across the supply filter, rather than in just one point across the down flow. 5. the cabinet should display the inflow and down flow air velocities and must incorporate an led indicator, visual & audible alarm to indicate excessive hepa filters loading, blower failure, airflow speed failure, incorrect window position. 6. the front of the cabinet must be angled 10 to help minimize glare. 7. the cabinet noise level must be less than 65 db(a) for a 4-foot cabinet. 8. cabinet with lights on and fan at operating speed should consume less than 400 watts or less 9. the cabinet must automatically reduce fan/blower motor speed to 30% when the front window sash is in closed position to ensure reduced energy consumption when the cabinet is not is use. 10. uv light must be programmable to allow for specific exposure times from 0 to 24 hours. 11. the cabinet should have provision to fit taps for vacuum, water and non-combustible gas. 12. the bio safety cabinet should be nsf certified with listing on nsf website. 13. the bio safety cabinet should incorporate hepa filter of the class h 14 en 1822 or better and having minimum efficiency of 99.995% at 0.3 m particle size. 14. ventilation system exhaust and inflow air volume approx 300-350 cfm 15. audible and visual alarms for hepa filter failure, blower failure, airflow speed failure, incorrect window position. 16. the cabinet should be provided with fixed / adjustable height stand, uv light and one set of detachable arms rest and one / two electrical outlet. 17. the drain pan of the bsc should be made of stainless steel. the drain pan should not be painted, or power coated. 18. cabinet should be ce certified and declaration of moc should be provided. 19. port provision for clean and safe routing for vacuum tubing and cables throughthe side of the bsc for improved organization and work efficiency., vacuum ovenspecification: 1.volume(l): 60-802.temperature range ( c): rt+5-2503.temperature resolution ( c): 0.1(at 100 c)4.temperature variation ( c): (at100 c)5.heating power (w): 21006.vaccum range 0 ~ 1 atm7.timer: 1min ~ 99hr59min8.vaccum connector (mm): 109.venting connector (mm): 1010.inner size (mm): 400x400x40011.dimension (mm): 625x585x710, constant temperature incubators
Tender For supply of complete led luminaries (36watt capacity) having diffuser acrylic cover with accessories at all colony office area and control room of unit no. 3 & 4 of gsecl tps, ukai.(et-5887 electrical colony)