Get complete information related to latest Diesel Flow Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Diesel Flow Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Diesel Flow Meter Tenders.
Tender For corrigendum : supply of engineer and fabrication work size 18 by 12 height 6 point 35 meter to 8 meters including fire sprinklers , dock area 7 by 4 meters , office area of 3 by 3 , ramp for forklift , canopy to cover complete docking and ramping area , vertical elevation from flooring , repository design , lighting conduit laying of pvc electrical conduit pipe 25mm by 32mm , wiring copper wire size 1 point 5 by 3 by 6 , board switch and sockets , lights and fans , lighting arrestor , earthing chemical earthing electrode , workstations including table chair almirah and other necessary items , split air conditioner , cctv surveillance system , rolling shutter door for warehouse , manual door , biometric access , office area entry door , fire line , fire hose reel and fire hydrant , sprinkler , smoke detector , fire pump , fire tank 25000l , solar system , electric forklift , project management consulting, project management execution and installation and commissioning and freight and training
Tender For e.i for setting up of work station system in the audit branch of administrative office in p.u campus, sector-14, chandigarh - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls/hffr pvc insulated copper conductor single core cable etc. as required (dsr 1.8), group c (dsr 1.8.3), rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable and 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required (dsr 1.15), group c (dsr 1.15.3), supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required (dsr 1.17), 3 x 2.5 sq. mm (dsr 1.17.12), 3 x 4 sq. mm (dsr 1.17.21), supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required (dsr 1.21), 25mm (dsr 1.21.2), supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required (dsr 1.22), 75 mm x 75 mm x 60 mm deep (dsr 1.22.1), supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (dsr 1.24), 5/6 a switch (dsr 1.24.1), 3 pin 5/6 a socket outlet (dsr 1.24.4), supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. (dsr 1.28), 3 module (dsr 1.28.2), 6 module (dsr 1.28.4), 8 module (dsr 1.28.5), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required (dsr 1.31), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required (dsr 1.32), supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (dsr 2.4), 4 way (4 + 12), double door (dsr 2.4.1), supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.(dsr 2.10), single pole (dsr 2.10.1), supplying and fixing dp sheet steel enclosure on surface/ recess along with 25/32 a 240 v "c" curve dp mcb complete with connections, testing and commissioning etc. as required. (dsr 2.16, providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (dsr 5.18), supplying, drawing, installation, testing and commissioning of cat6a utp 4 pair, 23 awg solid copper cable in existing conduit/ on surface, u/ftp, lszh, non-plenum, horizontal (solid) cable suitable for high speed data networking application supporting upto 10gbps over a 100 meter channel. the 4 unshielded twisted pairs (utp) cable with color coded insulation for easy indentification should have flame properties i.e. flammability test - iec 60332-1, smoke density - iec 61034, lszh standards compliance: ansi/tia- 568 c.2, iso/iec 11801
Tender For corrigendum : certain repair to b/r and e/m items in zone c under ge roorkee - demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed., m&l for brick work, with class b brick straight or curved on plan to any radius built in cement mortar (1:6) as in raising of manholes and septic tanks complete all as specified and directed, taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed, m&l for rendering 15 mm thick on fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth in cm 1:4 complete including mixing water proofing compound complete all as specified and directed, supply only water proofing compound complete all as specified and directed., m&l for rendering 15 mm thick on other than fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth in cm 1:6 complete all as specified and directed, m&l for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed, m&l for preparing newly plastered surface of wall and applying two coats of oil bound distemper complete all as specified and directed, m&l for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces and applying two coats of oil bound distemper, over and including a coat of 1 mm thick wall care putty with preparation of plastered surfaces complete all as specified and directed., m&l for preparation of old decorated wall surfaces by complete removal of existing treatment on walls including cornices by broming down with steel brush, scrapping down smoke soot, moulds moss and efflorescent salts and trading oil and grease spots and applying two coat of cement base paint inluding one mm thick cement base putty complete all as specified and directed., m&l for preparation of old decorated wall surfaces by complete removal of existing treatment on walls including cornices by broming down with steel brush, scrapping down smoke soot, moulds moss and efflorescent salts and trading oil and grease spots and applying two coats of 100% premium acrylic emulsion paint having voc less than 50 gm/litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces inluding one mm thick cement base putty all as specified and as directed. (note: painting of overhead tank min height 18 to 25 meter), m&l in repair for built in steel cup board with pressed steel frame of size 75 mmx45mmx1.25 mm thick with pressed steel shutter 1mm thick godrej pattern fixed to masonry wall by hold fast made out of 25x3 mm flat iron including ms hanging rod of 10 mm dia with bracket fixed on inner side of one leaf of shutter and on other leaf provision of ms peg set of 3 pegs including spray including locking arrangement spray painting with two coats of synthetic enamel paint over one coat of red oxide primer with two coats of synthetic enamel paint over one coat of red oxide primer all around on steel surface of frame & shutter and making good disturbed portion in cm (1:3) or pcc (1:2:4) type b-0 complete all as specified and directed., s&f in repair 110 mm dia pvc (swr) bends any radius with oval access door complete all as specified and directed, s&f in repair 75 mm dia pvc (swr) bends with access door any radius complete all as specified and directed, s&f in repair 75 mm dia pvc (swr) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to w