Web Analytics Made Easy - StatCounter

Digital Protection Relay Tenders

Get complete information related to latest Digital Protection Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Digital Protection Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Digital Protection Relay Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45308681 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For stage/rate contract for supply of key material/equipments required for operation/maintenance of 33kv lines and 33/11-6.6 kv receiving stations valid for the financial year 2026-27 or till finalization of next stage contract - power transformers, supply of transformer oil as per is: 335-1993 with latest amendments thereof, supply of buchhloz relay for 33/11-6.6 -6.6 kv transformer protection (10mva / 6.3 mva/ 5mva) as per is 3637:1966, supply of winding temperature indicator (wti) for 33/11-6.6 kv power transformer (10 mva / 6.3/ 5 mva ) as per relevant is 5561 standard., supply of oil temperature indicator (oti) for 33/11-6.6 kv for power transformer (10 mva / 6.3/ 5 mva )as per relevant is 5561 standard., supply of cork sheet 6 mm as per relevant is 5561 standard., supply of old sarees/dhoti cloth, supply of gaskets suitable for power transfomers, 33kv ct&pt, supply of 33/11-6.6kv power transformer (10/6.3/5 mva)bush rods with copper washers as per relevant is 3347 standard., hv side, lv side, supply of 33/11-6.6kv power transformer (10/6.3/5 mva)bushes as per relevant is 3347 standard., hv side, lv side, supply of 11 kv spout bushes (indoor type) conforming to relevant standards ammended up to date, supply of mechanical plunger (conforming to relevant standards ammended up to date ) for, 11 kv breakers (both incoming & outgoing), 33 kv vcbs both indoor & outdoor type, supply of 11 kv partition insulators/ bushes with inbuilt studs of required size conforming to relevant standards ammended up to date as per directions of site engineer, supply of dc connector for 11 kv panels conforming to relevant standards ammended up to date, supply of breather conforming to latest is 3202 (ammended up to date) for 10mva/ 6.3mva/ 5/ 3.15 mva., supply of silica gel as per is :3202, supply of o-ring oil sealing of sizes for power transformer bushes (hv/lv) as per is 3202., supply of galvanised iron angle/channel/flat per is :2062 grade "a" of sorts and sizes, g i channel 100x50x50x6 mm, g i channel 75x40x40x6 mm, g.i angle iron 65x65x6 mm, g.i angle iron 50x50x6 mm, g.i flat iron 40x6/ 50x6 mm, supply of arching horns (set of three pieces) for power transformer, supply of g.i bolt full thread of sorts and sizes with washers and nuts of different sorts and sizes, supply of 33kv current transformer (3-core) of reputed make,outdoor oil cooled, single phase (comprising of 3 no.) (as per is 2705 -1992 having ratio of is (is 2165, is 2705(i-iv), is 2099, is 5621, is 2071, is 335, is 13947(part i), iec 185,iec 270, iec 44(4), iec 171, iec 60, iec 8263, iec 815, indian electricity rules 2010), 400-200/5-5-5 a, 300-150/5-5-5 a, 250-125/5-5-5 a, 200-100/5-5-5 a, supply of 11 kv c.t.(2-core/3-core) of reputed make suitable for 11kv vcb panels (comprising of 3 no.) as per is (is 2165, is 2705(i-iv), is 2099, is 5621, is 2071, is 335, is 13947(part i), iec 185,iec 270, iec 44(4), iec 171, iec 60, iec 8263, iec 815, indian electricity rules 2003) having ratio:-, 800-400-200/5-5a, 750-375-187.5/5-5a, 600-300-150/5-5a, 400-200-100/5-5a, 200-100/5-5a, 150-75/5-5a, 100-50/5-5a, 50-25/ 5-5a, 33kv and 11kv outdoor type potential transformer, supply of 33kv potential transformer (comprising of 3 no.) of ratio 33kv/ 3 / 110v / 3 ,single phase,outdoor oil cooled, dead tank type pt as per is:3156 -1992, supply of 11kv potential transformer 11kv/ 3 / 110v / 3 three phase box type (combo unit) as per is :3156-1992, supply of 11kv potential transformer (comprising of 3 no.) 11kv/ 3 / 110v / 3 single phase seperate type as per is :3156-1992, 11kv and 33kv vcbs, supply of master trip relay 24-50 v rel 615 abb ied suitable for 11kv vcb switch gear panels (compitable for electric feild, pascal, scheinder, abb, essan l&t or any other equilant make), supply of digital protection relay adr 141c, rel 615 /abb ied,model no. er113 2 o/c + 1 e/f with high trip (mit113), auxiliary voltage = 0-36 volt conforming to iso 9001:2008 standards (compitable for electric fe

corporations/Associations/Others

CTN :45321428 Due date: 02 Jun, 202602 Jun, 2026 NA
Tender For auction sale of 11 kv ct scrap,lt ct burnt & damage scrap,disc fitting scrap,m.s. bolt & nut u/s,battery scrap,old battery damage scrap,spot billing machine (damage),transformer oil sludge scrap

corporations/Associations/Others

CTN :45285670 Due date: 30 May, 202630 May, 2026 NA
Tender For auction sale of 33 kv ct damaged scrap,33 kv pt damaged scrap,33 kv ct-pt damaged scrap,battery charger scrap,ups battery scrap 600 va scrap,ups battery scrap 3 kva scrap,11 kv damage vcb/ocb scrap,33 kv vcb 1200amp damage scrap,spot billing machine (damage) scrap

corporations/Associations/Others

CTN :45121599 Due date: 14 May, 202614 May, 2026 NA
Tender For auction sale of 11 kv damage vcb/ocb scrap,33 kv vcb 1200amp damage scrap,spot billing machine (damage) scrap,t/f stamping (core scrap)tf core stamping core rusted,steel scrap rail piecees,steel scrap rs joist,al cable scrap (other),scrap other "cu",conductor scrap, ht abc burnt scrap,aluminium scrap aaac & others,scrap ms iron scrap,ms scrap meltable,11kv ct 400/200/5a damage/scrap,ct o/d 33 kv ctr 200/100/1-1 a old&dam scrap

corporations/Associations/Others

CTN :45004854 Due date: 30 Apr, 202630 Apr, 2026 NA
Tender For auction sale of 11 kv damage vcb/ocb scrap,33 kv vcb 1200amp damage scrap,spot billing machine (damage) scrap,t/f stamping (core scrap)tf core stamping core rusted,steel scrap rail piecees,steel scrap rs joist,al cable scrap (other),conductor scrap, ht abc burnt scrap,aluminium scrap aaac & others,scrap ms iron scrap,ms scrap meltable

corporations/Associations/Others

CTN :44913587 Due date: 17 Apr, 202617 Apr, 2026 NA
Tender For auction sale of transformer channel scrap,steel scrap rail pieces,ms rail scrap,rail/r.s. joist off size scrap (o/u),battery charger scrap,battery scrap,old battery damage scrap,11 kv ct scrap,11 kv x-arm scrap,33 kv pin scrap,disc fitting scrap,emply oil drum scrap,m.s. bolt & nut u/s,spot billing machine (damage)

corporations/Associations/Others

CTN :44824836 Due date: 17 Apr, 202617 Apr, 2026 NA
Tender For auction sale of 33 kv ct damaged scrap,33 kv pt damaged scrap,33 kv ct-pt damaged scrap,battery charger scrap,ups battery scrap 600 va scrap,ups battery scrap 3 kva scrap,11 kv damage vcb/ocb scrap,33 kv vcb 1200amp damage scrap,spot billing machine (damage) scrap

State Government

CTN :44736760 Due date: 09 Apr, 202609 Apr, 2026 4.70 Lacs
Tender For tender for carrying out job of meter reading preparation and delivery of energy bills through spot billing machine and serving defaulter s notices to the consumers of esd hpsebl nagwain on monthly basis 3 months

corporations/Associations/Others

CTN :44661965 Due date: 30 Mar, 202630 Mar, 2026 NA
Tender For corrigendum : auction sale of battery charger scrap,ups battery scrap 600 va scrap,ups battery scrap 3 kva scrap,11 kv damage vcb/ocb scrap,33 kv vcb 1200amp damage scrap,spot billing machine (damage) scrap,t/f stamping (core scrap)tf core stamping core rusted

CTN :44456347 Due date: 28 Mar, 202628 Mar, 2026 NA
Tender For supply of contactor, ml12, 3 p, 415vm, coil 110v , potential transformer 11 kv 110 v, 3 ph , main contractor, 550v, 300a , hex head bolt , power contactor, 525v, 3 p, 110a , digital protection relay
 Loading, Please wait...

Connect us via What's Up