Tender For corrigendum : replacement of foam cushion of med exam table , replacement of castor wheel of instr trolley , replacement of sheet cushion and hand rest of wheel chair , replacement of castor wheels of cabinet trolley , replacement of side railing and wheels of advance icu bed , replacement of cutter blade of electric pop cutter , replacement of bp cuffs adult and pead of bp recording unit digital , replacement of ecg electrode and cable of cardiamat 6 channel ecg machine , replacement of battery and electrode cable of ecg machine bpl model cardiart 9108p , replacement of adult spo2 probes temp probe and ecg lead and pead spo2 probe and nibp extension line of multipara patient monitor , change of power battery ecg electrode cable of ecg machine 12 channel , transducer for invasive bp monitor of pediatric and adult multi parameter monitor with etco2 and ibp model contec ) /bid number : gem/2025/b/6496256 * /dated: 07-08-2025 & & / bid document 1 / 13
Tender For supply of light and sound--speaker/sound box powered -600 watt speaker/sound box powered -1200 watt speaker/sound box powered -1800 watt speaker/sound box powered -2000 watt monitor speaker powered -300 watt monitor speaker powered -600 watt amplifier included -1200 watts amplifier included -2000 watts amplifier included -3000 watts amplifier included -5000 watts audio recording a mixer with pen drive a hand cordless mic a mic/foot mic/bound mic a podium mic cordless collar mic microphone with led equalizer - 32 channel stereo echo system, light stand, par light, led light, general light unit - 1000 watt, baby mirror light unit - 1000 watt, follow light unit - 2500 hmia, smoke machine unit - 1500 watt, dimmer control unit - 24 kva dimmer control unit - 20 kva three phase wire main line, tse light stand, led wall unit - 1.6a led wall unit - 1.4a led wall lighting -ch.3a generator sound proof diesel and lighting device with operator -15 kvaa generator sound proof diesel and lighting device with operator -62 kvaa generator sound proof diesel and lighting device with operator -120 kvaa in case the work is completed for more than one day, what percentage of the total amount spent on items like light, sound, generator set etc. will be charged less. a ------- hence----------a max pickup/bolero pickup/truck fare for transportation of goods. a max pickup/bolero pickup/truck vehicle fare for transportation of goods for organizing cultural functions in other districts outside dehradun headquarters.
Tender For annual maintenance contract of digitalvoicerecorder system(vdrpu) installed at lumding tele control and badarpur tele control in lumdingdivision of n.f.railway for a period of three years by oem
Tender For corrigendum : purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-a