Get complete information related to latest Disc Insulator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Disc Insulator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Disc Insulator Tenders.
Tender For corrigendum : construction of transmission line - pcc poles supply and erection of pre-stressed cement concrete pole of suitable length with a given planting depth confirming to is-1678_1960_1978 below ground level in excavated pit of suitable dimensions complete in all respect as approved by engineer_in_charge at site pcc pole overall length 11 metre , planting depth 1.80 metre , w_l 400 kg pb csr 2020 item no 34.32(iii) , insulators supply and erection of insulators confirming to is_2544 and 5350 (test certificates of cpri) includes supply and erection of nuts bolts and other accessories whatsoever required at site for fixing it to the structure pole. the job is to be completed as approved by engineer_in_charge 11kv pin insulator with gi pin pb csr 2020 item no 34.35(i)(b) , stay sets supply and erection of stay set consisiting of 19_20mm dia.of suitable length gi stay rod duly threaded upto 300mm at one end and shaped on the other end ms plate size 30cm x 30cm x 6mm with 20mm dia hole drilled in the centre of the plate gi stay wire size 7_10 swg , gi thimble for stay binding , egg_strain insulator , ms elbow made out of 16mm plain sheet and a 20cm long piece of 50mm x 50mm x 6mm angle iron made to the shape as approved by engineer_in_charge. stay set complete shall be fixed to the pole by providing suitable size full clamps made out 50mm x 6mm size ms flat with required number of nut and bolts 16mm dia on one end and shall be embedded on the other end. the stay plate shall be covered with cement concrete having total volume of the concrete not less that 0.042cum. the job shall include excavation of pit and back filling and after pouring concrete with excavated soil etc. as approved_desired by the the engineer-incharge stay set consisiting of 19_20mm dia 2.4 metre long gi stay rod pb csr 2020 item no 34.35(ii)(b) , acsr conductor wolf 150mm2 , pole top brackets (galvanised) , v-shape cross arm 100x50mm , half clamp ms flat 50x5 , 11 kv polymeric discinsulators 70kn , danger plate , phase plate (set of 3) , barbed wire , earthing arrangement of 11kv poles , eye screw bolts 9inchx5_8 inch(galvanised) weight 0.483 kg. , nut and bolt ms off size , ms channel 100 x 50 x 6 - 2400 mm (galvanised) for h-pole , belting for h-pole 50 x 50 x 6mm . (galvanised) weight 9.90 kg , bracing for 4-pole 50 x 50 x 6mm . (galvanised) weight 14.49 kg , single tension fitting complete suitable for acsr wolf , pg clamp , full clamp ms flat 50x5 , ms angle 65x65x6 , erection charges
Tender For corrigendum : supply of pcc pole 8.5 mtr. long,stp pole 11 mtr. long,stone pad ,11 kv v type cross arm,11 kv cross arm clamp with n&b,11 kv pin insulator,11 kv g.i. pin with n&b,f-bracket,earthing of pole,acsr rabbit conductor,acsr weasel conductor,11 kv xlpe cable 3x185 sq.mm.,11 kv cable jointing kit o/d for 3x185 sq.mm. cable,stay set complete,t-off channel,clamp for t-off channel,11 kv discinsulator,11 kv disc fitting,concreating of pole,danger plate complete,barbed wire gi 1/2 per pole,dismantling and removal of existing conductor/cable/gi wire from the various area preparing their coils and then stacking in the respective jes (store) as per direction of supervising engineer. it includes the work of cartage, cost of labour, t&p carrier etc. required for proper completion of work.acsr weasel conductor scrap,steel & scrap,g.i. wire scrap,11 kv 3x185 sq.mm. xlpe cable scrap
Tender For corrigendum : providing of custom bid for services - replacement of faulty discinsulator string with new clr polymer insulators in 400 kv kathalguri mariani tl under mariani tlm
Tender For segregation of 11 kv mixed feeders at tonk circles of jaipur discom of rajasthan state under revamped reforms-based and results linked distribution sector scheme (rdss) on turnkey basis against tn-583 - pcc poles, pcc pole 9 mtrs long (400 kg), pcc pole 9 mtrs long (200 kg), outdoor 11 kv o/d vcb kiosk complete with accessories including use of special tools, armoured cable of size 2c x 4 sq.mm. 1100 volts pvc insulated including supplyof ferrules, control cable of size 12c x 2.5 sq.mm. 1100 volts pvc insulated including supply of ferrules, overhead steel cored aluminum acsr dog[100sqmm(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing, overhead steel cored aluminum acsr rabbit conductor in all respect, earthing rod sets for s/s made with ms rod (galvanized ) 20 mm dia, 3 meter length with gi wire and clamp as per latest specification and drawing adopted & approved by nigam., ctpt structure set (galvanized), 11kv ct pt set(200/5 amp.), mip meter box for meter with ttb, go double break without eb isolator on existing bracket complete in all respect as required including hardware, nut, bolts & washer etc., 11kv ( with 9 x 24 kv post insulator ) 400 amp., horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc., 11kv ( with 6 x 24 kv post insulator ) 1 set=3 nos, supply of insulators, 11kv porcelain disc.insulators b&s type 45kn, hardware for 11kv discinsulator b&s type 45kn, composite polymer insulators, 11kv polymer disc.insulators t&c type 45kn, hardware for 11kv discinsulator t&c type 45kn, 11 kv composite polymer pin insulator complete in all respect, pg clamps for suitable acsr dog conductor, pg clamps for suitable acsr rabbit conductor, 11 kv danger plate of size 200 x 250 mm complete in all respect, supply of angle and channel, m.s channel 100x50x6 mm, m.s channel 75x40x6 mm, m.s. flat 50 x 6 mm (galvanized), 1.4 mtr channel bracket with clamp, supply of lightening arrestors, substation type 9kv, 10ka station class (1set=3 nos.) lightening arrestors., 11kv double pole line structure set for cut point complete on existing poles in all respect with clamp, as required made from m.s.channel 100 x 50 x ismc ( 9.56 kg. per mtr.) isa m.s.angle 65 x 65 x 6 mm, m.s.angle 50 x 50 x 6 mm and m.s.flat 50 x 6 mm (galvanized as per is), gi stay set (galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300x300x4 mm,12 mm dia turn buckle) including stay clamps,, strain/guy insulator for stay set, 7/10 swg gi stay wire, gi wire 8swg, underground cable for working voltage of 11kv aluminium conductor (is 7098) cable xlpe armoured, under ground cable of size 3x185 sq.mm for 11 kv, g.i. pipe of 125 mm diameter, b-class (is:1239 mark), gi pipe for cable support at pole ( each 3.3 mtr ), cable for11 kv aluminum conductor xlpe armoured ht cable, xlpe 3x185 sq.mm h.s. on indoor type, xlpe 3x185 sq.mm h.s. on outdoor type, xlpe 3x185 sq.mm h.s.s.t. joint, 11.4 mtr. long lattice tower made of 50 x 50 x 6 mm m.s. angle with 50 x 6 mm m.s. flat for bracing as per nigam specification, 11kv cross arm with top hamper with clamps made of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm (galvanized), fixing of 11/0.4 kv substation structure set for three phase 63 kva transformer on double poles in all respect. weight (as per specification and drawing with go channel) approx=219.54 kg (all galvanized as per relevant is), 11 /0.4 kv al wound, three phase distribution transformer (completely self protected with provision of lt bushing box), 25 kva, 63 kva, 6.35/0.24kv s/s structure set for single phase transformer on single 9mtr, 400kg pcc pole in all respects., 11kv 100 amp drop out cum isolator with 3.0 amp. fuse & 12 kv post insulators., lt xlpe cable, size 4cx70 sq. mm, size 4cx120 sq. mm, aerial bunched cable, aerial bunched cable 3cx25+1x25 sqmm, aerial bunched cable 3cx50+1x35 sqmm, lt distribution pillar
Tender For supply of electric line materails - electrical items :, connector pipe to panther, connector panther to panther, connector panther to ab switch, connector pipe to ab switch, connector dog to ab switch, pg clamp for 80/100mm2 conductor, pg clamp for 232/150mm2 conductor, pg clamp(ring type) for 232/150mm2 conductor, led flood light out door with ip 66 protection rectangular (100 watt), al. winding wire, lt pin insulator with pin(porcelain type), lt pre-insulated mid span joint suitable 95mm 2 phase, insulation piercing connector for db charging, insulating piercing connector bracing suitable for t. joints, 33 kv discinsulator with fitting 90 kn (b&s) type polymer, 33 kv polymer type pin insulator with pin 10 kn, (nuts & washer), 33 kv post insulator, 33 kv fuse set, 11 kv (b&s type) discinsulator with fitting polymer, 70 kn, 11 kv polymer type pin insulator with pin 5 kn nuts & washer type, 11 kv fuse set, suitable lungs, suspension clamp (assembly suitable up to 70-85 sq mm bare messenger including 1 no suspension clamp with bracket two meter stainless steel strap & 2 no ss buckle), spring loaded (distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming & 3 outgoing 3 phase connection as per field requirement), dead end bracket suitable above 70 sq mm bare messenger including 1 no dead end bracket + i no dead end +2 mtr ss strap + 2 nos ss buckle.(minimum braking load 15 kn), jointing sleeve suitable for 150-232 sq mm, lt shackle insulator with strap porcelain type
Tender For repairing, overhauling of 6.6 kv overhead line and associated items , pin insulator, discinsulator of different feeder i.e. receiving pit, lagoon feeder, loading complex including earth pit maint. and transformer painting works at madhuban coal w