Tender For supply of call base repair of ems at telephone bhavan - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For repair and overhauling service - repair and overhauling services dsl l-50 to l-55 , e-41 to e-44 and h-69 for icgs c-411; dsl l-50 to l-55 , e-41 to e-44 and h-69 for icgs c411; no; buyer premises-icgs c-411 l-50: ship s boat davit not working due to defective rotary switch (25 amp, qty-02 nos.) and 10 pin male & female connector (20 amp) of remote assembly is broken/defective. defect to be rectified and proved for satisfactory operation. in-way job includes renewal and fitment of rotary switch and connector as per sample l-51: 01 no. ecdis ups (make-apc, cap-1500 va, 865 w) not working due to defective charging circuit and defective converter. defect to be rectified and proved for satisfactory operation. l-52: ship is fitted with 08 nos. flood lights (mercury/halogen type) onboard. all flood lights to be repaired/replace with flood lights as per policy in vogue. in way job includes removal and fitment of lights, clamps and wiring as per standards and proved for satisfactory operation. l-53: 01 no. hand set ptt of mf/hf communication unit (make: samyung, model: srg-2250) and 01 no mic of hf marine (make: icom, model: ic m802) is malfunctioning due to defective mic/cable and multi pin connector. defect to be rectified and proved for satisfactory operation. l-54: 02 in nos. splash proof microphone of main broadcast is malfunctioning due to defective mic and multi pin connector. defect to be rectified and proved for satisfactory operation. l-55: 02 in nos. of exhaust/supply fan in waterjet compartment not working due to defective bearing and showing low insulation. defect to be rectified and proved for satisfactory operation. in-way job includes repairing/renewal of motor trunking and welding of supporting clamps as per sample (mat: ss clamps and gi sheet) e-41: leakage observed in 02 nos. fuel ball valve in engine room. ball valve to be overhauled and pressure test to be done up to 1.5 times of working pressure. (dia: 50 nb, working pressure: 1.5 kg/cm2) e-42: performance of ac plant observed to be low view scaling found in ac condenser.ac condenser to be chemically cleaned and gasket (both ends) along with nut & bolt to be renewed as per sample. (gasket mat: rubber, nut & bolts mat: ss 316) e-43: 02 nos shaft seal cooling hose of waterjet along with adapter deteriorated due to aging/long usage. hose/adapter to be repaired/renewed as per sample. (mat: rubberized pressure hose, length:1.5 mtrs. e-44: domestic sea water pump is not developing sufficient discharge pressure. sea water pump to be overhauled and proved for satisfactory operations. inway job includes removal and fitment of pump to done. h-69: wooden locker at dining hall deteriorated and cracked. door of the locker perished. locker to be repaired/renewed. mat: wood..