Get complete information related to latest Dissolution System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dissolution System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dissolution System Tenders.
Tender For equipments for mechatronics and iot laboratory - 8051 micro controller kit [vptb-04], instrument cabinet, a.l293d morter driver b.stepper motor interface, 5v dc motor, traffic light control system: [tlc], level control system trainer, conveyor control module
Tender For corrigendum : providing of customized annual maintenance contract/cmc for pre-owned products - annual maintenance contract of bomb calorimeter (model 6200 si no m38085 and m105583, make parr instrument usa) installed in area coal analysis laboratory, kusmunda area; parr instrument usa; annual maintenance contract (amc); 10 ..
Tender For corrigendum : supply of chemistry lab equipment - procurement of chemistry lab equipment, uv visible spectrophotometer equipped with integrating sphereapplicable for both solid and liquid sample, powder sample kit, diffuse reflectance standards of 2%, 5%, 10%, 20%, 50%, 100%, neutral density filter to obtain linearity for transmittance, and pc control(configuration: insight software for instrument along with core i7 processor and 512gb ssd), electronic balancestainless steel weighing plate, measuring range resolution: 0.001 g, weighing capacity measuring range 120 g, parameter 0.001 g readability (1 mg), capacity 120 g, outside size 20.5 cm (8 in.) 35 cm (13.75 in.) 9 cm (3.5 in.) weighing pan diam. 115 mm (4.5 in.), ph meterrecorder output 0 to 10 mv/ph, 0 to 10 mv/100mv (adjustable), ph range 0-14 phph resolution 0. 01, ph temperature compensation 0 - 100 c, mv accuracy 1 mv, magnetic stirrercapacity 1 litre,stirring paddle q-19 9 x 25 mm,dimensions 150 x 220 x 150 mm, with hotplate, capacity 5 litres, double distillation unit1.5 lph, material borosilicate glass with double stage distillation setup, pyrogen free dimension 650 x 630 x 520mm, flame photometergeneral range ppm, serum range meq,i,urine range meq,i,resolution 0.1 ppm / 0.1 meq,curve at accuracy 2% of fsdisplay 128 x 64 graphical lcd average time in-built in software,flame system lpg & dry oil free air,detector photodiode,aspiration time 3 ml per minute,gas control adjustable with knob,flame failure auto detection,gas cut off automatic,ignition system auto ignition,automiseraxial flow type,dimensions instrument: 365 x 245 x 220 mm approx. (lxbxh),pc interface usb power supply 230 v ac 10%, 50 hz, chromatography chambersize 26x13x26 height 26inch material teak wood, potentiometerrange: 0 to 199.9 mvresolution: 0.1 mvrepeatability: 1mvaccuracy: 1 mv 1 digit input impedance :> 1010 ohms operating temperature : 10 c to 50 c display : 3.5 digit bright red seven segment led display with auto polarity indication power : 230 10% ac ,50hz dimensions : 76*275*170 mm (approx.) weight : 2 kg. (approx.) standard accessories glass electrode : 01 no. reference electrode : 01 no. silver electrode : 01 no. platinum electrode : 01 no. dust cover : 01 no. electrode stand & clamp : 01 no. instruction manual : 01 no., polarimetrytouch screen, no warmup time required when instrument turned on, measuring multiple scales, conductivity meterresolution 0.1 ppm voltage 220 v,ec resolution 0.1 temperature range 0-100 c probe conductivity cell weight 1.5 kg auto cell constant measurement manually cell constant =1k dimension 32/23/18cm display type 3 1/2 digit seven segment led display measurable conductivity range in ppm number of ranges 5 power 230-volt main type of temperature compensation manual no. of calibration points 1 temperature compensation auto cond. range 0-1000 m in 5 range 200m*,2m,20m,200m,1000m phase single phase usage laboratory frequency 50 hz power source electric, handy ph, tds, and conductivity meterph range (-) 2.00 to 16.00,ph accuracy 1%,ph resolution 0.01 ph, orp range 1000 mv,orp accuracy 1%,orp resolution 1 mv,conductivity range,0 to 100 ms/cm,conductivity accuracy 2%,conductivity resolution 1 s,tds accuracy 2%,tds resolution 1 ppm,salt range 0 to 50 ppt,salt accuracy 2%,salt resolution 1 ppm,temp range 0 to 100 deg c,temp accuracy 0.2,temp resolution 0.1 deg c,atc yes,power aaa (1.5v) x 4 batteries, printerconnectivity technology usb, networkprinting technology laser special feature automatic document feeder, fast printing, scanner, copier colour blackmodel name laserjet pro mfp m128fnprinter output monochromemax print speed monochrome 20item weight 11100 gramsprinter media size maximum a4, b5, a6, dl, envelope, ups3kva online ups with 1 year batteries warranty
Tender For supply, installation and trials of laboratory instruments equipment apparatus with training for quality control ii division at siliguri, p.w.(roads) directorate - nomenclature of machine/instrument and work required: supply, of only vacuum pump cum controller required for existing digital 4 station vacuum indicator for absolute viscosity test. the same will have to he installed on the existing machine and after installation, necessary trials are to be carried out. relevant is code: is: 1206: 2022 (part ii). specification: the pump connected with the vacuum system should be capable of maintaining a vacuum within 2 0.05 cm of the desired level up to and including 30 cm of mercury, and should have the capability of holding the desired pressure throughout the period of a particular test. the pump should have both analogue (with divisions of 0.05 cm of hg) and digital pressure gauge (capability of displaying minimum of 0.05 cm of hg). the vacuum pump controller should be supplied with a 4-position manifold to apply vacuum simultaneously up to four positions and perform viscosity determinations. equipped with dedicated on/off switches for each position and supplied with blue silicon tubing. the pump should have the capability of withholding the pressure set for tests and also maintain it throughout the test. vacuum pump should be the part of vacuum system [pump should be inbuilt with in the vacuum system along with analogue and digital display of vacuum). note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply 2. necessary tests and trials will have to be carried out to the satisfaction of engineers of q.c.-ii division at siliguri. 3. two year comprehensive warranty of total system from the date of satisfactory completion of onsite installation, commissioning and training of the instrument., nomenclature of machine/instrument and work required: supply, installation of u-tube, modified reverse flow viscometer for opaque liquid required for kinematic test of bitumen. details: tube no. 6 & 7 with 01 no. stand each. relevant is code: is 1206 (part 3): 2021 specification: note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply. 2. necessary tests and trials will have to be carried out to the satisfaction of engineers of qc-ii division at siliguri. 3. two year comprehensive warranty of total system from the date of satisfactory completion of onsite installation, commissioning and training of the instrument., nomenclature of machine/instrument and work required: supply & installation of serological water bath. specification: the bath should have double walled structure, having facility of digital controller cum indicator. the bath should have stirring arrangement. inside wall should be of stainless-steel seamless ss 304 seamless, min. thickness 1.0 mm, with rounded corners for easy cleaning with proper drainage system having ptfe valve and hose pipe (15mm inner dia. min). outer wall to be of ms and properly insulated with cfc-free high-density insulation. minimum temp. range is 5°c to 95°c, 20.2°c. size should be minimum 28 l: -600 w 400d 350 h mm; for 8 standard racks, with adjustable height, compatible with common test tubes (10-50 mm dia.) and other bottles/beakers. note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply. 2. necessary tests and trials will have to be carried out to the satisfaction, nomenclature of machine/instrument and work required: supply & installation of burette stand with clamp specification: boss head & rod (with stainless steel corrosion resistant rod (length 18") the rod diameter is 1 cm and solid black coated support stand base (6"x4"). should be made of high-quality anti-corrosion & rust-proof stainless steel. the base should be padded to prevent scratches on the surface and better gri
Tender For repairing and painting, creation of chambers in post graduate laboratory, instrument and equipment room and scientist chamber of dept. of surgery, college of veterinary science and animal husbandry under bau, kanke
Tender For construction of laboratory for mri on the roof top of science block under mumty for the accommodation of instrument/ equipment procured from administration of ut ladakh.
Tender For corrigendum : kerala water authority funds deposit supply and installationof lab equipments for maintaining quality standards in various schemes under p h division palakkad - supply of lab equipments to various wss and rwss under p h division palakkad, od114374/2025-2026:supply and installation of jar test apparatus with the specifications are (1). number of stirres - 6 minimum, (2). rpm- 25 to 200 rpm or better, (3). capacity of single stirrer unit- 1 l, (4). control -digital control (digital timer & r.p.m counter), (5). stirrer paddle material (with appropriate corrosion protective coating) - stainless steel, (6). power single phase (220 - 240 volts), (7). illumination -fluorescent tube ; llumination should not contribute heat to the system, (8). warranty period -2 years. etc; complete., od114368/2025-2026:supply , installation and calibration of digital nephelo turbidity meter with the specifications are ; (1). range : 0 to i000ntu , (2). range selection : manual /automatic , (3). resolution : 0.1 ntu or better , (4). accuracy : +or- 3% or better, (5). calibration : 4 points minimum (manual/auto selection) , (6). light source : led/tungsten halogen lamp , (7). detector : photodiode , (8). display : lcd/led , (9). power : 230v +or- 10 % , 50 to 60hz, (10). accessories: matching test tubes(4 nos minimum ) and light shield, l000ntu solution 500 ml minimum, (11). instrument manual with specification details(hard copy) , (12). warranty : 2 years for the entire instrument etc ; complete., od114367/2025-2026:supply , installation and calibration of bench top ph meter with the specifications are (i). ph - range : 0.00 to 14.00 ph or better, resolution : 0.01or better, accuracy : +or- 0.02 ph or better, calibration points : 3 points minirnum, buffer options : : standard buffers (ii). mv - range : 0 to +or- l999mv, resolution : i mv or better, accuracy : + or - 1 mv or better (iii). temperature - 0.0 to 99 degree c or better, resolution : 0.1 degree c or better, accuracy : + 0.5 degree c or better (iv). electrode qpecification: single junction ,body-plastic /unbreakable, gel filled electrode atc probe and electrode stand should also be provided. (v). meter features - 1) lcd i led display, 2) dual display of ph or mv with temperature , 3) with auto buffer recognition, 4) off set/slope should be displayed , 5) power 230v +or - 10%, 6) buffer solutions 7 .0, 4.0, 9.2 ph (100m1 minimum) should be provided, 7) should provide all accessories for smooth functioning of the equipment, 8) hard copy of user manual with instrument specification, 9) warranty: 1 year for entire insruments etc; complete., od114377/2025-2026:supply of laboratory equipments including electronic weighing balances,etc. with 2 year warrenty including conveyance charges, od114750/2025-2026:supply and installation of digital conductivity meter 308 with the specifications are (i). conductivity - 1). range : 0.1 us to 100 ms (6 decadic ranges) , 2). accuracy : +or - 1% of fs + or - digit. 3). resolution : 0.001 micro.s (ii). tds - range : 0.1ppm to 100 ppt (6 decadic ranges ), accuracy : + or - 1% of fs (iii). temperature - temperature : 0 degree c to 100 degree c( auto / manual ), resolution : 0.1 degree c. , accuracy : + or - 0.2 degree c. etc; complete with 2 year warrenty, od114370/2025-2026:supply of buffer solution for ph 4 and ph 7(500ml bottle)