Tender For supply of surgical consumables - pressure garment for forearm large size , pressure garment for forearm medium size , pressure garment for forearm xl size , pressure garment full leg large size , pressure garment full leg medium size , pressure garment full leg small size , pressure garment full leg xl size , pressure garment half leg large size , pressure garment half leg medium size , pressure garment half leg small size , pressure garment half leg xl size , pressure garment fulll upper limb small size , pressure garment hand gloves xl size , pressure garment hand gloves large size , pressure garment hand gloves medium size , cystoscopy drapes with attached leggings and funnel for water collection , customized laprotomy drape with smms spun lace fabic with 06 drape 100 x 100 cm, 02 drapes 150 x 200 cm, 02 bags for instrument 02 adhesie drain bags , lithotomy pack ii contains under buttocks drape plastic reinforced 40x 46 qty x 1 leggings with 6 cuff 31x 41 qty x 1 c absorbent towel qty x 1 conforming to bis certification level 4 , cardiac multimarker panel for quantitative estimation of troponinit myoglobin and d-dimer compatible with triage meter box of 25 tests bid number/ ( ( ) ): gem/2024/b/5608028 dated/* : 12-12-2024 bid document/ 1 1 / 23
Tender For design, engineering, manufacture, quality surveillance, testing at suppliers works, transportation, supply on for destination basis, retrofit, erection, testing and commissioning of plant scada, distributedcontrolsystem(dcs), control and protection system, metering, synchronizing for all units including supply, laying, testing, termination of cables and networking, communication of ewly supplied and existing system, dismantling of existing panels & cables, etc. for nagjhari, kadra, kodasalli and supa power houses of kpcl
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous
Tender For supply of distributedcontrolsystem - supply as per mr item sl. no. 1 , site work for mr item sl. no. 1 , transportation for mr item sl. no. 1 , mandatory spares for mr item sl. no. 1 , training for owner personnel on dcs plc and its sub-systems at vendor works as per the mr , training for owner personnel on dcs plc and its sub systems at site as per the mr , five years post warranty comprehensive annual maintenance contract as per the mr